627 research outputs found

    District-level rice-yield estimation for Orissa using satellite data

    Get PDF
    Remotely-sensed data transformed into a vegetation index (radiance ratio of near infrared to red) has been related to district rice yields for Orissa using IRS-1A LISS-I data of kharif seasons 1988-89 and 1989-90. Using the empirical relation of the first year, estimation of rice yield has been done for the 1989-90 kharif season. Deviations in the districts of coastal tract and central tableland ranged from 1.9 to 11.1 percent whereas deviations were larger in Eastern Ghat and Northern plateau of Orissa

    Factors determining failure of intertrochanteric fracture fixation with a dynamic hip screw: a retrospective analysis

    Get PDF
    Background: The intertrochanteric fractures are extra capsular fractures of proximal femur in the trochanteric region. Different fixation techniques were tried for intertrochanteric fractures, with variety of implants but the dynamic hip screw fixation is most widely accepted treatment. However, several authors have concluded that sliding compression screws may be associated with several complications such as perforation of the femoral head, loss of reduction caused by excessive sliding of the lag screw, non-union, shortening of the affected limb and pain. This study was carried out to ascertain the factors that contributed to mechanical failure at our institute.Methods: We retrospectively reviewed 92 patients with unilateral intertrochanteric fracture treated with a sliding hip screw between July 2015 and April 2017. Postoperative radiographs were studied for any loss of reduction, which was defined as a varus deformity greater than 10°, perforation of the femoral head, extrusion of the lag screw of more than 20 mm, or metal failure. The Pearson chi-square test was used to assess the relationship between failure and osteoporosis. A p value of less than 0.05 was considered to be significant.Results: Results revealed a significant relationship between failure and osteoporosis. A possible relationship between the stability of the fracture on Evans’ classification and osteoporosis on Singh’s index was investigated which revealed a high positive correlation between the failure rates of unstable fractures with osteoporosis.Conclusions: An unstable fracture combined with osteoporosis, has higher percentage of fixation failure leading to other methods of treatment like hemiarthroplasty.

    Coccydynia

    Get PDF
    Coccydynia is a term that refers to pain in the region of the coccyx. Most cases are associated with abnormal mobility of the coccyx which may trigger a chronic inflammatory process leading to degeneration of this structure. In some patients this instability may be detected on dynamic radiographs. Nonsurgical management remains the gold standard treatment for coccydynia, consisting of decreased sitting, seat cushioning, coccygeal massage, stretching, manipulation, local injection of steroids or anesthetics, and postural adjustments. Those patients who fail these conservative modalities may potentially benefit from coccygectomy. However, surgical intervention is typically reserved for patients with evidence of advanced coccygeal instability (e.g., subluxation or hypermobility) or spicule formation, as this population appears to exhibit the greatest improvement postoperatively

    Successful ACL reconstruction with a variant of the pes anserinus

    Get PDF
    An anatomical variant of the pes anserinus encountered during anterior cruciate ligament reconstructive surgery which has not been previously described is discussed. During routine harvesting, the sartorius fascia was incised and the semitendinosus and gracilis tendons were identified. At the distal portion, it was noted that each tendon gave off an additional tendinous slip. The slip from the semitendinosus tendon had attached to the gracilis tendon and vice versa, thereby creating a double pes anserinus. This variant was used to construct the graft, and at 1 year review the patient had returned to full sporting activities with no complications encountered

    Trends in peri-operative performance status following resection of high grade glioma and brain metastases: The impact on survival

    Get PDF
    Objectives: Maximal surgical resection of high grade brain tumours is associated with improved overall survival (OS). It carries the risk of neurological deterioration leading to worsening performance status (PS), which may affect overall survival and preclude patients from adjuvant therapy. We aim to review the changes in performance status of patients undergoing resection of high grade tumours and metastases and the impact of changes on overall survival. Patients and methods: A prospective study of the perioperative performance status of 75 patients who underwent primary resection of malignant primary brain tumour or solitary metastasis in a single centre. Data on patients’ demographics, tumour histology and overall survival were also collected. WHO performance status was recorded pre-operatively and at intervals following surgery. Results: Of the 75 patients (35 males, 40 females, median age 61 years at diagnosis), 50 had primary malignant brain tumours, 25 had metastasis. Although PS dropped at postoperative day 1 in 14 patients (18.7%), 28% improved by day 5 and there was significant improvement by day 14 (41%, p=0.02). The number of patients with PS 3 or worse changed from 4% pre-operatively (n=3) to 8% (n=6). Overall survival is better in those whose PS remained improved or unchanged at 2 weeks after surgery compared to those whose PS deteriorated; high grade glioma median survival 15.67 vs. 2.4 months (p=0.005) and metastasis median survival 8.53 vs.2.33 months (p=0.001). Conclusion: Our data demonstrates that although PS may deteriorate immediately after surgery, the majority of patients regain their baseline PS or improve by 2 weeks postoperatively; decisions on fitness for adjuvant treatment should therefore be delayed until then. In those patients whose PS declines following surgery overall survival is poor

    Acute isolated acetabular fracture following a game of squash: a case report

    Get PDF
    Although hip injuries do not account a large amount of the Sports Physician's workload they can result in significant morbidity. We present a case where an acetabular fracture was sustained in a relatively young female while playing squash without any history of fall or injury but was treated successfully non-operatively. Such patients who present with acute hip pain must not be dismissed as simply having a soft tissue injury

    High yield synthesis of electrolyte heating assisted electrochemically exfoliated graphene for electromagnetic interference shielding applications

    Get PDF
    Herein, we demonstrate a facile one pot synthesis of graphene nanosheets by electrochemical exfoliation of graphite. In the present study, we report a significant increase in the yield of graphene by electrolyte heating assisted electrochemical exfoliation method. The obtained results of heating assisted electrochemically exfoliated graphene (utilizing H2SO4 + KOH + DW) synthesis clearly exhibit that the yield increases similar to 4.5 times i.e. from similar to 17% (room temperature) to similar to 77% (at 80 degrees C). A plausible mechanism for the enhanced yield based on lattice expansion and vibration of intercalated ions has been put forward and discussed in details. The quality of graphene was examined by Raman, XPS, FTIR, AFM, SEM, TEM/HRTEM and TGA techniques. The Raman as well as morphogenesis results confirm the quality of the graphene nanosheets. We have used this graphene as electromagnetic interference shielding material where a comparatively large quantity of graphene is required. This graphene exhibits enhanced shielding effectiveness (46 dB at 1 mm thickness of stacked graphene sheets in frequency region 12.4 to 18 GHz) as compared to conventional electromagnetic interference shielding materials, which is greater than the recommended limit (similar to 30 dB) for techno-commercial applications. Thus the present work is suggestive for future studies on enhancement of yield of high quality graphene by proposed method and the use of synthesized graphene in electromagnetic interference shielding and other possible applications

    NGS QC Toolkit: A Toolkit for Quality Control of Next Generation Sequencing Data

    Get PDF
    Next generation sequencing (NGS) technologies provide a high-throughput means to generate large amount of sequence data. However, quality control (QC) of sequence data generated from these technologies is extremely important for meaningful downstream analysis. Further, highly efficient and fast processing tools are required to handle the large volume of datasets. Here, we have developed an application, NGS QC Toolkit, for quality check and filtering of high-quality data. This toolkit is a standalone and open source application freely available at http://www.nipgr.res.in/ngsqctoolkit.html. All the tools in the application have been implemented in Perl programming language. The toolkit is comprised of user-friendly tools for QC of sequencing data generated using Roche 454 and Illumina platforms, and additional tools to aid QC (sequence format converter and trimming tools) and analysis (statistics tools). A variety of options have been provided to facilitate the QC at user-defined parameters. The toolkit is expected to be very useful for the QC of NGS data to facilitate better downstream analysis
    corecore