18 research outputs found
Sequential ¹⁸F-fluorodeoxyglucose positron emission tomography (¹⁸F-FDG PET) scan findings in patients with extrapulmonary tuberculosis during the course of treatment—a prospective observational study
BACKGROUND: Initial studies of tuberculosis (TB) in macaques and humans using ¹⁸F-FDG positron emission tomography (PET) imaging as a research tool suggest its usefulness in localising disease sites and as a clinical biomarker. Sequential serial scans in patients with extrapulmonary TB (EPTB) could inform on the value of PET-CT for monitoring response to treatment and defining cure. PATIENTS AND METHODS: HIV-negative adults with EPTB from eight sites across six countries had three ¹⁸F-FDG PET/CT scans: (i) within 2 weeks of enrolment, (ii) at 2 months into TB treatment and (iii) at end of ATT treatment. Scanning was performed according to the EANM guidelines. ¹⁸F-FDG PET/CT scans were performed 60 ± 10 min after intravenous injection of 2.5–5.0 MBq/kg of ¹⁸F-FDG. FINDINGS: One hundred and forty-seven patients with EPTB underwent 3 sequential scans. A progressive reduction over time of both the number of active sites and the uptake level (SUVmax) at these sites was seen. At the end of WHO recommended treatment, 53/147 (36.0%) patients had negative PET/CT scans, and 94/147 (63.9%) patients remained PET/CT positive, of which 12 patients had developed MDR TB. One died of brain tuberculoma. INTERPRETATION: Current ⁸F-FDG PET/CT imaging technology cannot be used clinically as a biomarker of treatment response, cure or for decision-making on when to stop EPTB treatment. PET/CT remains a research tool for TB and further development of PET/CT is required using new Mycobacterium tuberculosis-specific radiopharmaceuticals targeting high-density surface epitopes, gene targets or metabolic pathways
PET/CT features of extrapulmonary tuberculosis at first clinical presentation: a cross-sectional observational ¹⁸F-FDG imaging study across six countries
BACKGROUND: A large proportion of the huge global burden of Extrapulmonary tuberculosis (EPTB) are treated empirically without accurate definition of disease sites, and extent of multi-organ disease involvement. Positron emission tomography (PET) imaging using 18F-FDG in TB could be a useful imaging technique for localising disease sites and extent of disease.
METHODS: We conducted a study of HIV-negative adult patients with a new clinical diagnosis of EPTB across 8 centres located in 6 countries: India, Pakistan, Thailand, South Africa, Serbia, and Bangladesh to assess the extent of disease and common sites involved at first presentation. 18F-FDG PET/CT scans were performed within 2 weeks of presentation.
FINDINGS: A total of 358 patients with EPTB (189 females; 169 males) were recruited over 45 months. Age range 18-83 years (females: median 30 years; males: median 38 years). 350/358 (98%) patients (183 female, 167 male) had positive scan. 118/350 (33.7%) had a single extrapulmonary site and 232/350 (66.3%) had more than one site (organ) affected. Lymph nodes, skeletal, pleura and brain were common sites. 100/358 (28%) of EPTB patients had 18F-FDG PET/CT positive sites in the lung. 110 patients were 18F-FDG PET/CT positive in more body sites than were noted clinically at first presentation and 160 patients had the same number of positive body sites.
INTERPRETATION: 18F-FDG PET/CT scan has potential for further elucidating the spectrum of disease, pathogenesis of EPTB, and monitoring the effects of treatment on active lesions over time, and requires longitudinal cohort studies, twinned with biopsy and molecular studies
Worldwide diagnostic reference levels for single-photon emission computed tomography myocardial perfusion imaging: findings from INCAPS.
OBJECTIVES: This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). BACKGROUND: Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. RESULTS: The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m-labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. CONCLUSIONS: This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs
Guiding principles on the education and practice of theranostics.
The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists.
To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice.
Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries.
The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics
Cardiovascular testing recovery in Latin America one year into the COVID-19 pandemic: An analysis of data from an international longitudinal survey.
The INCAPS COVID Investigators Group, listed by name in the Appendix, thank cardiology and imaging professional societies worldwide for their assistance in disseminating the survey to their memberships. These include alphabetically, but are not limited to, American Society of Nuclear Cardiology, Arab Society of Nuclear Medicine, Australasian Association of Nuclear Medicine Specialists, Australia-New Zealand Society of Nuclear Medicine, Belgian Society of Nuclear Medicine, Brazilian Nuclear Medicine Society, British Society of Cardiovascular Imaging, Conjoint Committee for the Recognition of Training in CT Coronary Angiography Australia and New Zealand, Consortium of Universities and Institutions in Japan, Danish Society of Cardiology, Gruppo Italiano Cardiologia Nucleare, Indonesian Society of Nuclear Medicine, Japanese Society of Nuclear Cardiology, Moscow Regional Department of Russian Nuclear Medicine Society, Philippine Society of Nuclear Medicine, Russian Society of Radiology, Sociedad Española de Medicina Nuclear e Imagen Molecular, Society of Cardiovascular Computed Tomography, and Thailand Society of Nuclear Medicine.Peer reviewe
Nuclear cardiology practices and radiation exposure in Africa: results from the IAEA Nuclear Cardiology Protocols Study (INCAPS)
OBJECTIVE: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiation-associated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. METHODS: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. RESULTS: Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. CONCLUSION: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI
Nuclear cardiology practices and radiation exposure in Africa: results from the IAEA Nuclear Cardiology Protocols Study (INCAPS)
OBJECTIVE: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiation-associated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. METHODS: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. RESULTS: Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. CONCLUSION: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI
Global Impact of COVID-19 on Nuclear Medicine Departments: An International Survey in April 2020.
The coronavirus disease 2019 (COVID-19) pandemic has placed significant challenges on health-care systems worldwide, whether in the preparation, response, or recovery phase of the pandemic. This has been primarily managed by dramatically reducing in- and outpatient services for other diseases and implementing infection prevention and control measures. The impact of the pandemic on nuclear medicine departments and their services has not yet been established. The aim of this online survey was to evaluate the impact of COVID-19 on nuclear medicine departments. Methods: A web-based questionnaire, made available from April 16 to May 3, 2020, was designed to determine the impact of the pandemic on in- and outpatient nuclear medicine departments, including the number of procedures, employee health, availability of radiotracers and other essential supplies, and availability of personal protective equipment. The survey also inquired about operational aspects and types of facilities as well as other challenges. Results: A total of 434 responses from 72 countries were registered and analyzed. Respondents reported an average decline of 54% in diagnostic procedures. PET/CT scans decreased by an average of 36%, whereas sentinel lymph-node procedures decreased by 45%, lung scans by 56%, bone scans by 60%, myocardial studies by 66%, and thyroid studies by 67%. Of all participating centers, 81% performed radionuclide therapies, and they reported a reduction of 45% on average in the last 4 wk, ranging from over 76% in Latin America and South East Asia to 16% in South Korea and Singapore. Survey results showed that 52% of participating sites limited their 99mTc/99Mo generator purchases, and 12% of them temporarily cancelled orders. Insufficient supplies of essential materials (radioisotopes, generators, and kits) were reported, especially for 99mTc/99Mo generators and 131I, particularly in Africa, Asia, and Latin America. Conclusion: Both diagnostic and therapeutic nuclear medicine procedures declined precipitously, with countries worldwide being affected by the pandemic to a similar degree. Countries that were in the postpeak phase of the pandemic when they responded to the survey, such as South Korea and Singapore, reported a less pronounced impact on nuclear medicine services; however, the overall results of the survey showed that nuclear medicine services worldwide had been significantly impacted. In relation to staff health, 15% of respondents experienced COVID-19 infections within their own departments
Worldwide variation in the use of nuclear cardiology camera technology, reconstruction software, and imaging protocols
OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions
Correction (Journal of the American College of Cardiology (2021) 77(2) (173–185), (S0735109720378694), (10.1016/j.jacc.2020.10.054)
Einstein AJ, Shaw LJ, Hirschfeld C, Williams MC, Villines TC, Better N, Vitola JV, Cerci R, Dorbala S, Raggi P, Choi AD, Lu B, Sinitsyn V, Sergienko V, Kudo T, Nørgaard BL, Maurovich-Horvat P, Campisi R, Milan E, Louw L, Allam AH, Bhatia M, Malkovskiy E, Goebel B, Cohen Y, Randazzo M, Narula J, Pascual TNB, Pynda Y, Dondi M, Paez D, on behalf of the INCAPS COVID Investigators Group International Impact of COVID-19 on the Diagnosis of Heart Disease J Am Coll Cardiol 2021;77:173–85 The INCAPS COVID Investigators Group, listed in the appendix, was not coded properly when this article initially published. As a result, they were not indexed on PubMed. Their names have now been coded properly to facilitate inclusion in the PubMed indexing. The publisher apologizes for this error