31 research outputs found

    Subcutaneous tissue reaction to castor oil bean and calcium hydroxide in rats

    Get PDF
    Castor oil bean cement (COB) is a new material that has been used as an endodontic sealer, and is a candidate material for direct pulp capping. OBJECTIVE: The purpose of this study was to evaluate the biocompatibility of a new formulation of COB compared to calcium hydroxide cement (CH) and a control group without any material, in the subcutaneous tissue of rats. MATERIAL AND METHODS: The materials were prepared, packed into polyethylene tubes, and implanted in the rat dorsal subcutaneous tissue. Animals were sacrificed at the 7th and 50th days after implantation. A quantitative analysis of inflammatory cells was performed and data were subjected to ANOVA and Tukey's tests at 5% significance level. RESULTS: Comparing the mean number of inflammatory cells between the two experimental groups (COB and CH) and the control group, statistically significant difference (p=0.0001) was observed at 7 and 50 days. There were no significant differences (p=0.111) between tissue reaction to CH (382 inflammatory cells) and COB (330 inflammatory cells) after 7 days. After 50 days, significantly more inflammatory cells (p=0.02) were observed in the CH group (404 inflammatory cells) than in the COB group (177 inflammatory cells). CONCLUSIONS: These results demonstrate that the COB cement induces less inflammatory response within long periods

    Accuracy of five electronic foramen locators with different operating systems: an ex vivo study

    Get PDF
    OBJECTIVE: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. MATERIAL AND METHODS: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. RESULTS: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. CONCLUSIONS: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15
    corecore