2,835 research outputs found

    Kondo effect of non-magnetic impurities and the co-existing charge order in the cuprate superconductors

    Full text link
    We present a theory of Kondo effect caused by an induced magnetic moment near non-magnetic impurities such as Zn and Li in the cuprate superconductors. Based on the co-existence of charge order and superconductivity, a natural description of the induced moment and the resulting Kondo effect is obtained in the framework of bond-operator theory of microscopic t-J-V Hamiltonian. The local density of state near impurities is computed in a self-consistent Bogoliubov-de Gennes theory which shows a low-energy peak in the middle of superconducting gap. Our theory also suggests that the charge order can be enhanced near impuries.Comment: 5 pages, 4 figure

    History dependent magnetoresistance in lightly doped La_{2-x}Sr_{x}CuO_{4} thin films

    Full text link
    The in-plane magnetoresistance (MR) in atomically smooth La_{2-x}Sr_{x}CuO_{4} thin films grown by molecular-beam-epitaxy was measured in magnetic fields B up to 9 T over a wide range of temperatures T. The films, with x=0.03 and x=0.05, are insulating, and the positive MR emerges at T<4 K. The positive MR exhibits glassy features, including history dependence and memory, for all orientations of B. The results show that this behavior, which reflects the onset of glassiness in the dynamics of doped holes, is a robust feature of the insulating state.Comment: 4 pages, 4 figures, International School and Workshop on Electronic Crystals (ECRYS-2011); to appear in Physica

    Pancreas-Targeted NIR Fluorophores for Dual-Channel Image-Guided Abdominal Surgery

    Get PDF
    Objective: Pancreas-related complications are some of the most serious ones in abdominal surgery. The goal of this study was to develop and validate novel near-infrared (NIR) fluorophores that would enable real-time pancreas imaging to avoid the intraoperative pancreatic injury. Design: After initial screening of a large NIR fluorophore library, the performance of 3 selected pancreas-targeted 700 nm NIR fluorophores, T700-H, T700-F, and MB, were quantified in mice, rats, and pigs. Dose ranging using 25 and 100 nmol, and 2.5 μmol of T700-F, and its imaging kinetics over a 4 h period were tested in each species. Three different 800 nm NIR fluorophores were employed for dual-channel FLARE™ imaging in pigs: 2 μmol of ZW800-1 for vessels and kidney, 1 μmol of ZW800-3C for lymph nodes, and 2 μmol of ESNF31 for adrenal glands. Results: T700-F demonstrated the highest signal to background ratio (SBR), with peak SBR at 4 h postinjection in mice. In pigs, T700-F produced an SBR ≥ 2 against muscle, spleen, and lymph nodes for up to 8 h after a single intravenous injection. The combination of T700-F with each 800 nm NIR fluorophore provided simultaneous dual-channel intraoperative imaging of pancreas with surrounding organs in real time. Conclusion: Pancreas-targeted NIR fluorophores combined with the FLARE dual-channel imaging system enable the real-time intraoperative pancreas imaging which helps surgeons perform safer and more curative abdominal surgeries

    Absence of large nanoscale electronic inhomogeneities in the Ba(Fe1-xCox)2As2 pnictide

    Full text link
    75As NMR and susceptiblity were measured in a Ba(Fe1-xCox)2As2 single crystal for x=6% for various field H values and orientations. The sharpness of the superconducting and magnetic transitions demonstrates a homogeneity of the Co doping x better than +-0.25%. On the nanometer scale, the paramagnetic part of the NMR spectra is found very anisotropic and very narrow for H//ab which allows to rule out the interpretation of Ref.[6] in terms of strong Co induced electronic inhomogeneities. We propose that a distribution of hyperfine couplings and chemical shifts due to the Co effect on its nearest As explains the observed linewidths and relaxations. All these measurements show that Co substitution induces a very homogeneous electronic doping in BaFe2As2, from nano to micrometer lengthscales, on the contrary to the K doping.Comment: 6 pages, 4 figure

    Design and RF measurements of a 5 GHz 500 kW window for the ITER LHCD system

    Get PDF
    International audienceCEA/IRFM is conducting R&D efforts in order to validate the critical RF components of the 5 GHz ITER LHCD system, which is expected to transmit 20 MW of RF power to the plasma. Two 5 GHz 500 kW BeO pill-box type window prototypes have been manufactured in 2012 by the PMB Company, in close collaboration with CEA/IRFM. Both windows have been validated at low power, showing good agreement between measured and modeling, with a return loss better than 32 dB and an insertion loss below 0.05 dB. This paper reports on the window RF design and the low power measurements. The high power tests up to 500kW have been carried out in March 2013 in collaboration with NFRI. Results of these tests are also reported. In the current ITER LHCD design, 20 MW Continuous Wave (CW) of Radio-Frequency power at 5 GHz are expected to be generated and transmitted to the plasma. In order to separate the vacuum vessel pressure from the cryostat waveguide pressure, forty eight 5 GHz 500kW CW windows are to be assembled on the waveguides at the equatorial port flange. For nuclear safety reasons, forty eight additional windows could be located in the cryostat section, to separate and monitor the cryostat waveguide pressure from the exterior transmission line pressure. These windows are identified as being one of the main critical components for the ITER LHCD system since first ITER LHCD studies [1] [2] [3] or more recently [4] [5] , and clearly require an important R&D effort. In this context and even if the LHCD system is not part of the construction baseline, the CEA/IRFM is conducting a R&D effort in order to validate a design and the performances of these RF windows. In order to begin the assessment of this need, two 5 GHz 500 kW/5 s pill-box type windows prototypes have been manufactured in 2012 by the PMB Company in close collaboration with the CEA/IRFM [6]. The section 2 of this paper reports the RF and mechanical design of a 5 GHz window. Some features of the mechanical design and the experimental RF measurements at low power are reported in section 3. High power results, made in collaboration with NFRI, are detailed in section 4. The development of CW windows is discussed in the conclusion. 2-RF AND MECHANICAL DESIGN The proposed 5 GHz RF window is based on a pill-box design [2] , i.e. a ceramic brazed in portion of a circular waveguide, connected on either side to a rectangular waveguide section. Typical design rules of thumb of such device are circular section diameter about the same size of the diagonal of the rectangular waveguide (cf. FIGURE 1). Without taking into account the ceramic, the circular section length is approximately half a guided wavelength of the circular TE 11 mode, in order for the device to act as a half-wave transformer. Once optimized, taking into account the ceramic, matching is correct only for a narrow band of frequency and is very sensitive to the device dimensions and the ceramic relative permittivity. The heat losses in the ceramic, which have to be extracted by an active water cooling, depends on the inside electric field topology and of ceramic dielectric loss (loss tangent). Undesirable modes due to parasitic resonances can be excited in the ceramic volume, raising the electric field an

    Glissile dislocations with transient cores in silicon

    Full text link
    We report an unexpected characteristic of dislocation cores in silicon. Using first-principles calculations, we show that all the stable core configurations for a non-dissociated 60^\circ dislocation are sessile. The only glissile configuration, previously obtained by nucleation from surfaces, surprinsingly corresponds to an unstable core. As a result, the 60^\circ dislocation motion is solely driven by stress, with no thermal activation. We predict that this original feature could be relevant in situations for which large stresses occur, such as mechanical deformation at room temperature. Our work also suggests that post-mortem observations of stable dislocations could be misleading, and that mobile unstable dislocation cores should be taken into account in theoretical investigations

    The tempo of cetacean cranial evolution

    Get PDF
    The evolution of cetaceans (whales and dolphins) represents one of the most extreme adaptive transitions known, from terrestrial mammals to a highly specialized aquatic radiation that includes the largest animals alive today. Many anatomical shifts in this transition involve the feeding, respiratory, and sensory structures of the cranium, which we quantified with a high-density, three-dimensional geometric morphometric analysis of 201 living and extinct cetacean species spanning the entirety of their ∼50-million-year evolutionary history. Our analyses demonstrate that cetacean suborders occupy distinct areas of cranial morphospace, with extinct, transitional taxa bridging the gap between archaeocetes (stem whales) and modern mysticetes (baleen whales) and odontocetes (toothed whales). This diversity was obtained through three key periods of rapid evolution: first, the initial evolution of archaeocetes in the early to mid-Eocene produced the highest evolutionary rates seen in cetaceans, concentrated in the maxilla, frontal, premaxilla, and nasal; second, the late Eocene divergence of the mysticetes and odontocetes drives a second peak in rates, with high rates and disparity sustained through the Oligocene; and third, the diversification of odontocetes, particularly sperm whales, in the Miocene (∼18-10 Mya) propels a final peak in the tempo of cetacean morphological evolution. Archaeocetes show the fastest evolutionary rates but the lowest disparity. Odontocetes exhibit the highest disparity, while mysticetes evolve at the slowest pace, particularly in the Neogene. Diet and echolocation have the strongest influence on cranial morphology, with habitat, size, dentition, and feeding method also significant factors impacting shape, disparity, and the pace of cetacean cranial evolution
    corecore