152 research outputs found

    Negative Refraction and Left-handed electromagnetism in Microwave Photonic Crystals

    Full text link
    We demonstrate negative refraction of microwaves in metallic photonic crystals. The spectral response of the photonic crystal, which manifests both positive and negative refraction, is in complete agreement with band-structure calculations and numerical simulations. The negative refraction observed corresponds to left-handed electromagnetism and arises due to the dispersion characteristics of waves in a periodic medium. This mechanism for negative refraction is different from that in metamaterials.Comment: 13 pages, 4 figure

    Microwave properties of superconducting MgB2

    Get PDF
    Measurements of 10 GHz microwavesurface resistance, Rs, of dense MgB2wire and pellet are reported. Significant improvements are observed in the wire with reduction of porosity. The data lie substantially above the theoretical estimates for a pure Bardeen–Cooper–Schrieffer s-wave superconductor. However, the Rs (20 K) of the wire is an order of magnitude lower than that of polycrystalYBa2Cu3O6.95 and matches with single-crystal YBa2Cu3O6.95. The results show promise for the use of MgB2 in microwave applications

    A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples

    Get PDF
    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one

    Elevated maternal lipoprotein (a) and neonatal renal vein thrombosis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Renal vein thrombosis, although rare in adults, is well recognized in neonates and is one of the most common manifestations of neonatal thromboembolic events. The etiology of renal vein thrombosis remains unidentified in the majority of cases. We report a case of renal vein thrombosis in a neonate associated with elevated maternal lipoprotein (a).</p> <p>Case presentation</p> <p>A full-term female infant, appropriate for gestational age, was born via spontaneous vaginal delivery to an 18-year-old primigravida. The infant's birth weight was 3680 g and the Apgar scores were eight and nine at 1 and 5 minutes respectively. Evaluation of the infant in the newborn nursery revealed a palpable mass in the right lumbar area. Tests revealed hematuria and a high serum creatinine level of 1.5 mg/dl. An abdominal ultrasound Doppler flow study demonstrated an enlarged right kidney, right renal vein thrombosis, and progression of the thrombosis to the inferior vena cava. There was no evidence of saggital sinus thrombosis. An extensive work-up of parents for hypercoagulable conditions was remarkable for a higher plasma lipoprotein (a) level of 73 mg/dl and an elevated fibrinogen level of 512 mg/dl in the mother. All paternal levels were normal. The plasma lipoprotein (a) level in the neonate was also normal. The neonate was treated with low molecular weight heparin (enoxaparin) at 1.5 mg/kg/day every 12 hours for 2 months, at which time a follow-up ultrasound Doppler flow study showed resolution of the thrombosis in both the renal vein and the inferior vena cava.</p> <p>Conclusion</p> <p>There have been no studies to date that have explored the effect of abnormal maternal risk factors on fetal hemostasis. A case-control study is required to investigate whether elevated levels of maternal lipoprotein (a) may be a risk factor for neonatal thrombotic processes. Although infants with this presentation are typically treated with anticoagulation, there is a lack of evidence-based guidelines. Treatment modalities vary between study and treatment centers which warrants the establishment of a national registry.</p

    Non-linear microwave impedance of short and long Josephson Junctions

    Full text link
    The non-linear dependence on applied acac field (bωb_{\omega}) or current (iω% i_{\omega}) of the microwave (ac) impedance Rω+iXωR_{\omega}+iX_{\omega} of both short and long Josephson junctions is calculated under a variety of excitation conditions. The dependence on the junction width is studied, for both field symmetric (current anti-symmetric) and field anti-symmetric (current symmetric) excitation configurations.The resistance shows step-like features every time a fluxon (soliton) enters the junction, with a corresponding phase slip seen in the reactance. For finite widths the interference of fluxons leads to some interesting effects which are described. Many of these calculated results are observed in microwave impedance measurements on intrinsic and fabricated Josephson junctions in the high temperature superconductors, and new effects are suggested. When a % dc field (bdcb_{dc}) or current (idci_{dc}) is applied, interesting phase locking effects are observed in the ac impedance ZωZ_{\omega}. In particular an almost periodic dependence on the dc bias is seen similar to that observed in microwave experiments at very low dc field bias. These results are generic to all systems with a cos(ϕ)\cos (\phi) potential in the overdamped limit and subjected to an ac drive.Comment: 7 pages, 11 figure

    Association of incident hip fracture with the estimated femoral strength by finite element analysis of DXA scans in the Osteoporotic Fractures in Men (MrOS) study

    Get PDF
    Finite element model can estimate bone strength better than BMD. This study used such a model to determine its association with hip fracture risk and found that the strength estimate provided limited improvement over the hip BMDs in predicting femoral neck (FN) fracture risk only. INTRODUCTION: Bone fractures occur only when it is loaded beyond its ultimate strength. The goal of this study was to determine the association of femoral strength, as estimated by finite element (FE) analysis of DXA scans, with incident hip fracture as a single condition or with femoral neck (FN) and trochanter (TR) fractures separately in older men. METHODS: This prospective case-cohort study included 91 FN and 64 TR fracture cases and a random sample of 500 men (14 had a hip fracture) from the Osteoporotic Fractures in Men study during a mean ± SD follow-up of 7.7 ± 2.2 years. We analysed the baseline DXA scans of the hip using a validated plane-stress, linear-elastic FE model of the proximal femur and estimated the femoral strength during a sideways fall. RESULTS: The estimated strength was significantly (P < 0.05) associated with hip fracture independent of the TR and total hip (TH) BMDs but not FN BMD, and combining the strength with BMD did not improve the hip fracture prediction. The strength estimate was associated with FN fractures independent of the FN, TR and TH BMDs; the age-BMI-BMD adjusted hazard ratio (95% CI) per SD decrease of the strength was 1.68 (1.07-2.64), 2.38 (1.57, 3.61) and 2.04 (1.34, 3.11), respectively. This association with FN fracture was as strong as FN BMD (Harrell's C index for the strength 0.81 vs. FN BMD 0.81) and stronger than TR and TH BMDs (0.8 vs. 0.78 and 0.81 vs. 0.79). The strength's association with TR fracture was not independent of hip BMD. CONCLUSIONS: Although the strength estimate provided additional information over the hip BMDs, its improvement in predictive ability over the hip BMDs was confined to FN fracture only and limited

    Artificial graphene as a tunable Dirac material

    Full text link
    Artificial honeycomb lattices offer a tunable platform to study massless Dirac quasiparticles and their topological and correlated phases. Here we review recent progress in the design and fabrication of such synthetic structures focusing on nanopatterning of two-dimensional electron gases in semiconductors, molecule-by-molecule assembly by scanning probe methods, and optical trapping of ultracold atoms in crystals of light. We also discuss photonic crystals with Dirac cone dispersion and topologically protected edge states. We emphasize how the interplay between single-particle band structure engineering and cooperative effects leads to spectacular manifestations in tunneling and optical spectroscopies.Comment: Review article, 14 pages, 5 figures, 112 Reference
    corecore