3,470 research outputs found

    Experimental and analytical determination of characteristics affecting light aircraft landing-gear dynamics

    Get PDF
    An experimental and analytical investigation was conducted to determine which characteristics of a light aircraft landing gear influence gear dynamic behavior significantly. The investigation focused particularly on possible modification for load control. Pseudostatic tests were conducted to determine the gear fore-and-aft spring constant, axial friction as a function of drag load, brake pressure-torque characteristics, and tire force-deflection characteristics. To study dynamic tire response, vertical drops were conducted at impact velocities of 1.2, 1.5, and 1.8 m/s onto a level surface; to determine axial-friction effects, a second series of vertical drops were made at 1.5 m/s onto surfaces inclined 5 deg and 10 deg to the horizontal. An average dynamic axial-friction coefficient of 0.15 was obtained by comparing analytical data with inclined surface drop test data. Dynamic strut bending and associated axial friction were found to be severe for the drop tests on the 10 deg surface

    QUANTITATIVE ANALYSIS OF SHAPE VARIATION IN TYPE AND MODERN POPULATIONS OF MERIDION (BACILLARIOPHYCEAE)

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65187/1/j.1529-8817.2001.037001175.x.pd

    Factors Associated With Retinal Vessel Diameters in an Elderly Population: the Thessaloniki Eye Study

    Get PDF
    Purpose: To identify the factors associated with retinal vessel diameters in the population of the Thessaloniki Eye Study. Methods: Cross-sectional population-based study (age ≥ 60 years). Subjects with glaucoma, late age-related macular degeneration, and diabetic retinopathy were excluded from the analyses. Retinal vessel diameters were measured using the IVAN software, and measurements were summarized to central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), and arteriole to venule ratio (AVR). Results: The analysis included 1614 subjects. The hypertensive group showed lower values of CRAE (P = 0.033) and AVR (P = 0.0351) compared to the normal blood pressure (BP) group. On the contrary, the group having normal BP under antihypertensive treatment did not have different values compared to the normal BP group. Diastolic BP (per mm Hg) was negatively associated with CRAE (P < 0.0001) and AVR (P < 0.0001), while systolic BP (per mm Hg) was positively associated with CRAE (P = 0.001) and AVR (P = 0.0096). Other factors significantly associated included age, sex, alcohol, smoking, cardiovascular disease history, ophthalmic medication, weight, and IOP; differences were observed in a stratified analysis based on BP medication use. Conclusions: Our study confirms previous reports about the association of age and BP with vessel diameters. The negative correlation between BP and CRAE seems to be guided by the effect of diastolic BP as higher systolic BP is independently associated with higher values of CRAE. The association of BP status with retinal vessel diameters is determined by diastolic BP status in our population. Multiple other factors are also independently associated with retinal vessel diameters

    Editorial: Ecosystem Services and Disservices Provided by Plant-Feeding Predatory Arthropods

    Get PDF
    Editorial of the Research Topic issue on Ecosystem Services and Disservices Provided by Plant-Feeding Predatory Arthropod

    Universality of the helimagnetic transition in cubic chiral magnets: Small angle neutron scattering and neutron spin echo spectroscopy studies of Fe1−x_{1-x}Cox_xSi

    Full text link
    We present a comprehensive Small Angle Neutron Scattering (SANS) and Neutron Spin Echo Spectroscopy (NSE) study of the structural and dynamical aspects of the helimagnetic transition in Fe1−x_{1-x}Cox_xSi with xx = 0.30. In contrast to the sharp transition observed in the archetype chiral magnet MnSi, the transition in Fe1−x_{1-x}Cox_xSi is gradual and long-range helimagnetic ordering coexists with short-range correlations over a wide temperature range. The dynamics are more complex than in MnSi and involve long relaxation times with a stretched exponential relaxation which persists even under magnetic field. These results in conjunction with an analysis of the hierarchy of the relevant length scales show that the helimagnetic transition in Fe1−x_{1-x}Cox_xSi differs substantially from the transition in MnSi and question the validity of a universal approach to the helimagnetic transition in chiral magnets

    Achieving provider engagement: providers' perceptions of implementing and delivering integrated care

    Get PDF
    The literature on integrated care is limited with respect to practical learning and experience. Although some attention has been paid to organizational processes and structures, not enough is paid to people, relationships, and the importance of these in bringing about integration. Little is known, for example, about provider engagement in the organizational change process, how to obtain and maintain it, and how it is demonstrated in the delivery of integrated care. Based on qualitative data from the evaluation of a large-scale integrated care initiative in London, United Kingdom, we explored the role of provider engagement in effective integration of services. Using thematic analysis, we identified an evolving engagement narrative with three distinct phases: enthusiasm, antipathy, and ambivalence, and argue that health care managers need to be aware of the impact of professional engagement to succeed in advancing the integrated care agenda
    • …
    corecore