50 research outputs found

    Hemodynamic sensor in cardiac implantable electric devices: the endocardial accelaration technology

    Get PDF
    There have been substantial progresses in the technology of cardiac implantable electric devices (CIEDs) during the past decades. One of the progresses is represented by the development of a hemodynamic sensor embedded at the tip of a pacing lead that measures myocardial contractility by the analysis of myocardial mechanical vibrations occurring during the cardiac cycle. This sensor, providing continuous hemodynamic monitoring, could play an important role in clinical practice because of several clinical applications in CIEDs recipients. The objectives of this work are to report how this sensor operates and to review the main findings about its clinical applications

    Prevention of long‐lasting atrial fibrillation through antitachycardia pacing in DDDR pacemakers

    Get PDF
    Objective The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. Methods Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. Results A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). Conclusions In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing
    corecore