37,195 research outputs found
High Energy Colliders
We consider the high energy advantages, disadvantages and luminosity
requirements of hadrons, leptons and photon-photon colliders. Technical
problems in obtaining increased energy in each type of machine are presented.
The machines relative size are also discussed.Comment: LaTeX, 27 pages, 8 figures (eps, ps). Submitted to the Proceedings of
the Princeton's 250th Anniversary Conference on Critical Problems in Physic
High Luminosity Muon Collider Design
Muon Colliders have unique technical and physics advantages and disadvantages
when compared with both hadrons and electron machines. They should be regarded
as complementary. Parameters are given of a 4 TeV high luminosity muon-muon
collider, and of a 0.5 TeV demonstration machine. We discuss the various
systems in such muon collider.Comment: LaTeX 5 pages 4 figure
Future Colliders
The high energy physics advantages, disadvantages and luminosity requirements
of hadrons, of leptons and photon-photon colliders are considered. Technical
arguments for increased energy in each type of machine are presented. Their
relative size, and the implications of size on cost are discussed.Comment: LaTeX, 10 pages, 10figure
Error estimation in the histogram Monte Carlo method
We examine the sources of error in the histogram reweighting method for Monte
Carlo data analysis. We demonstrate that, in addition to the standard
statistical error which has been studied elsewhere, there are two other sources
of error, one arising through correlations in the reweighted samples, and one
arising from the finite range of energies sampled by a simulation of finite
length. We demonstrate that while the former correction is usually negligible
by comparison with statistical fluctuations, the latter may not be, and give
criteria for judging the range of validity of histogram extrapolations based on
the size of this latter correction.Comment: 7 pages including 3 postscript figures, typeset in LaTeX using the
RevTeX macro packag
EKG isolator
Light beam transmits heartbeat signal from electrodes on patient to electrocardiograph without exposing patient to possible severe electrical shock. System provides complete isolation between patient and EKG instrumentation
Excimer lasers
A theoretical and experimental investigation into the possibility of achieving CW discharge pumped excimer laser oscillation is reported. Detailed theoretical modeling of capillary discharge pumping of the XeF and KXe and K2 excimer systems was carried out which predicted the required discharge parameters for reaching laser threshold on these systems. Capillary discharge pumping of the XeF excimer system was investigated experimentally. The experiments revealed a lower excimer level population density than predicted theoretically by about an order of magnitude. The experiments also revealed a fluorine consumption problem in the discharge in agreement with theory
Launch vehicle wind and turbulence response by nonstationary statistical methods
Nonstationary adjoint algorithm for determining launch vehicle flight loads due to winds and turbulenc
A Pulsed Synchrotron for Muon Acceleration at a Neutrino Factory
A 4600 Hz pulsed synchrotron is considered as a means of accelerating cool
muons with superconducting RF cavities from 4 to 20 GeV/c for a neutrino
factory. Eddy current losses are held to less than a megawatt by the low
machine duty cycle plus 100 micron thick grain oriented silicon steel
laminations and 250 micron diameter copper wires. Combined function magnets
with 20 T/m gradients alternating within single magnets form the lattice. Muon
survival is 83%.Comment: 4 pages, 1 figures, LaTeX, 5th International Workshop on Neutrino
Factories and Superbeams (NuFact 03), 5-11 Jun 2003, New Yor
- …