22,349 research outputs found
Protein Supplementation as Related to Sources of Protein for Growing-Finishing Lambs
The objective of this study was to evaluate commercially available sources of supplemental protein in diets for growing and finishing lambs. Supplements were selected to differ in protein in diets for growing and finishing lambs. Supplements were selected to differ in protein solubility and amino acid profile and were expected to be degraded at different rates in the rumen to furnish protein post-ruminally varying in dietary and bacterial origin. If the principles concerning these parameters reported by other investigators would be applicable, response in terms of growth and feed utilization would be a measure of the value of the supplements for productive purposes
SVOM pointing strategy: how to optimize the redshift measurements?
The Sino-French SVOM mission (Space-based multi-band astronomical Variable
Objects Monitor) has been designed to detect all known types of gamma-ray
bursts (GRBs) and to provide fast and reliable GRB positions. In this study we
present the SVOM pointing strategy which should ensure the largest number of
localized bursts allowing a redshift measurement. The redshift measurement can
only be performed by large telescopes located on Earth. The best scientific
return will be achieved if we are able to combine constraints from both space
segment (platform and payload) and ground telescopes (visibility).Comment: Proceedings of Gamma-Ray Bursts 2007 conference, Santa Fe, USA, 5-9
November 2007. Published in AIP conf. proc. 1000, 585-588 (2008
Decoupling a Cooper-pair box to enhance the lifetime to 0.2 ms
We present a circuit QED experiment in which a separate transmission line is
used to address a quasi-lumped element superconducting microwave resonator
which is in turn coupled to an Al/AlO/Al Cooper-pair box (CPB) charge
qubit. In our measurements we find a strong correlation between the measured
lifetime of the CPB and the coupling between the qubit and the transmission
line. By monitoring perturbations of the resonator's 5.44 GHz resonant
frequency, we have measured the spectrum, lifetime (), Rabi, and Ramsey
oscillations of the CPB at the charge degeneracy point while the CPB was
detuned by up to 2.5 GHz . We find a maximum lifetime of the CPB was s for to 4.5 GHz. Our measured 's are consistent with
loss due to coupling to the transmission line, spurious microwave circuit
resonances, and a background decay rate on the order of
s of unknown origin, implying that the loss tangent in the AlO
junction barrier must be less than about at 4.5 GHz, about 4
orders of magnitude less than reported in larger area Al/AlO/Al tunnel
junctions
- …