27 research outputs found

    Estudo comparativo da microdureza de materiais resinosos indiretos

    Get PDF
    The purpose of this study was to compare the microhardness of four indirect composite resins. Forty cylindrical samples were prepared according to the manufacturers recommendations using a Teflon mold. Ten specimens were produced from each tested material, constituting four groups (n=10) as follows: G1 - Artglass; G2 - Sinfony; G3 - Solidex; G4 - Targis. Microhardness was determined by the Vickers indentation technique with a load of 300g for 10 seconds. Four indentations were made on each sample, determining the mean microhardness values for each specimen. Descriptive statistics data for the experimental conditions were: G1 - Artglass (mean ±standard deviation: 55.26 ± 1.15HVN; median: 52.6); G2 - Sinfony (31.22 ± 0.65HVN; 31.30); G3 - Solidex (52.25 ± 1.55HVN; 52.60); G4 - Targis (72.14 ± 2.82HVN; 73.30). An exploratory data analysis was performed to determine the most appropriate statistical test through: (I) Levene's for homogeneity of variances; (II) ANOVA on ranks (Kruskal-Wallis); (III) Dunn's multiple comparison test (0.05). Targis presented the highest microhardness values while Sinfony presented the lowest. Artglass and Solidex were found as intermediate materials. These results indicate that distinct mechanical properties may be observed at specific materials. The composition of each material as well as variations on polymerization methods are possibly responsibles for the difference found in microhardness. Therefore, indirect composite resin materials that guarantee both good esthetics and adequate mechanical properties may be considered as substitutes of natural teeth.O objetivo deste estudo foi comparar a microdureza de 4 resinas compostas indiretas. Quarenta amostras cilíndricas foram obtidas com o auxílio de uma matriz de teflon, seguindo-se as recomendações dos fabricantes. Foram obtidas 10 amostras para cada material testado, contituindo-se 4 grupos (n=10) como se segue: G1-Artglass; G2-Sinfony; G3-Solidex; G4-Targis. A microdureza foi determinada pela técnica da indentação Vickers com uma carga de 300g por 10 segundos. Quatro indentações foram realizadas em cada amostra, obtendo-se um valor médio. Os dados da análise estatística descritiva para cada condição experimental foram: G1-Artglass (média ± desvio padrão:55,26 ± 1,15HVN; mediana: 52,6); G2- Sinfony (31,22 ± 0,65HVN; 31,30); G3- Solidex (52,25 ± 1,55HVN; 52,60); G4- Targis (72,14 ± 2,82HVN; 73,30). Uma análise exploratória dos dados foi realizada para determinar o teste estatístico mais apropriado: (I) Teste de Levene para variâncias homogêneas; (II) Teste de ANOVA (Kruskal-Wallis); (III) Teste de comparação múltipla de Dunn. O Targis apresentou os maiores valores de microdureza, enquanto que o Sinfony apresentou os menores valores. O Artglass e o Solidex se comportaram como materiais intermediários. Estes resultados indicaram que propriedades mecânicas distintas podem ser observadas nos materiais. A composição de cada material, bem como as variações nos métodos de polimerização são possivelmente responsáveis pelas diferenças observadas na microdureza. Portanto, materiais resinosos indiretos que garantam estética e propriedades mecânicas satisfatórias podem ser considerados como substitutos dos dentes naturais

    Avaliação da contração de polimerização de três resinas compactáveis, medida por picnômetro a gás

    Get PDF
    Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.A Odontologia Restauradora moderna tem se destacado nos últimos anos e as resinas compostas, aliadas aos sistemas adesivos, têm sido muito empregadas para restaurações de dentes anteriores e posteriores. A evolução das resinas compostas tem sido constatada na melhoria do seu comportamento estético e no aumento da sua resistência à compressão e à abrasão. Apesar dos avanços mencionados, a contração de polimerização, inerente a esse material, continua sendo uma grande deficiência e, por enquanto, impossível de ser evitada. Nesta pesquisa a contração de polimerização de três resinas compostas compactáveis, Filtek P60 (3M), Prodigy Condensável (Kerr) e SureFil (Dentsply/Caulk), variando-se a distância entre a fonte de luz e a superfície das resinas em 2 mm e 10 mm, foi avaliada pelo método da picnometria a gás. O aparelho picnômetro Accupyc 1330 (Micromeritics, EUA) mede o deslocamento de gás hélio com grande precisão, permitindo medições rápidas e fiéis do volume das resinas compostas antes e após a polimerização, sem interferência da temperatura e da umidade. Os resultados mostraram que não houve diferenças estatisticamente significantes entre as três resinas avaliadas. Independentemente do tipo de resina composta, também não houve diferenças significantes para as distâncias de polimerização de 2 mm e 10 mm

    Avaliação in vitro da resistência adesiva ao cisalhamento entre a dentina bovina, cimentos resinosos e materiais restauradores indiretos, tratados ou não com jato de óxido de alumínio, ácido fluorídrico e silano

    No full text
    The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 daysNeste trabalho avaliamos in vitro a resistência adesiva aos testes de cisalhamento na dentina bovina, com as seguintes variáveis: cimentos resinosos Enforce e Panavia F; materiais restauradores Art Glass, IPS Empress 2 e Targis e o tratamento das superfícies destes materiais com jato de óxido de alumínio, ácido fluorídrico e silano, nos períodos de 24h e 30 dias. Foram utilizados 288 dentes bovinos hígidos de animais com três anos de idade, com os quais foram confeccionados os corpos-de-prova, em caixas de resina poliéster. Os testes foram executados em máquina de ensaios mecânicos lnstron, modelo 430, com célula de 500kg de carga e com velocidade da ponta de 0,5 mm/min. Os resultados obtidos em kgf foram transformados em MPa e analisados estatisticamente pelo ANOVA, teste de Tukey e Box-Whisker Plot. O material IPS Empress 2 tratado com jato de óxido de alumínio, ácido fluorídrico e silano, cimentado com Panavia F e estocado em água destilada a 37°C, durante trinta dias, quando submetido aos testes de resistência ao cisalhamento, mostrou os melhores resultado

    Influence of bleaching treatment on flexural resistance of hybrid materials.

    No full text
    The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials

    A comparison of microhardness of indirect composite restorative materials

    No full text
    The purpose of this study was to compare the microhardness of four indirect composite resins. Forty cylindrical samples were prepared according to the manufacturerÂ’s recommendations using a Teflon mold. Ten specimens were produced from each tested material, constituting four groups (n=10) as follows: G1 - Artglass; G2 - Sinfony; G3 - Solidex; G4 - Targis. Microhardness was determined by the Vickers indentation technique with a load of 300g for 10 seconds. Four indentations were made on each sample, determining the mean microhardness values for each specimen. Descriptive statistics data for the experimental conditions were: G1 - Artglass (mean ±standard deviation: 55.26 ± 1.15HVN; median: 52.6); G2 - Sinfony (31.22 ± 0.65HVN; 31.30); G3 - Solidex (52.25 ± 1.55HVN; 52.60); G4 - Targis (72.14 ± 2.82HVN; 73.30). An exploratory data analysis was performed to determine the most appropriate statistical test through: (I) Levene's for homogeneity of variances; (II) ANOVA on ranks (Kruskal-Wallis); (III) Dunn's multiple comparison test (0.05). Targis presented the highest microhardness values while Sinfony presented the lowest. Artglass and Solidex were found as intermediate materials. These results indicate that distinct mechanical properties may be observed at specific materials. The composition of each material as well as variations on polymerization methods are possibly responsibles for the difference found in microhardness. Therefore, indirect composite resin materials that guarantee both good esthetics and adequate mechanical properties may be considered as substitutes of natural teeth

    Surface roughness of packable composite resins polished with various systems

    No full text
    Purpose: The aim of this study was to evaluate the surface roughness of four packable composite resins, SureFil™ (Dentsply, Petrópolis, Rio de Janeiro, Brazil), Prodigy Condensable™ (Kerr Co., Orange, CA, USA), Filtek P60™ (3M do Brasil, São Paulo, Brazil), and ALERT® (Jeneric/Pentron, Inc., Wallingford, CT, USA) and one microhybrid composite resin (Filtek Z250™, 3M do Brasil) after polishing with four finishing systems. Materials and Methods: Twenty specimens were made of each material (5 mm in diameter and 4 mm high) and were analyzed with a profilometer (Perthometer® S8P, Perthen, Mahr, Germany) to measure the mean surface roughness (Ra). The specimens were then divided into four groups according to the polishing system: group 1 - Sof-Lex™ (3M do Brasil), group 2 - Enhance™ (Dentsply), group 3 - Composite Finishing Kit (KG Sorensen, Barueri, São Paulo, Brazil), and group 4 - Jiffy Polisher Cups® (Ultradent Products, Inc., South Jordan, UT, USA). The specimens were polished and then evaluated for Ra, and the data were subjected to analysis of variance, analysis of covariance, and Tukey's test (p = .05). Results: The mean Ra of SureFil polished with Sof-Lex was significantly lower than that of KG points. Prodigy Condensable polished with Enhance showed a significantly less rough surface than when polished with Sof-Lex. Filtek P60 did not exhibit a significant difference with the various polishing systems. For ALERT the lowest mean Ra was obtained with Sof-Lex and the highest mean Ra with KG points. Regarding Filtek Z250, polishing with KG and Jiffy points resulted in a significantly lower mean Ra than when polished with Enhance. Conclusions: Packable composite resins display variable roughness depending on the polishing system used; the Sof-Lex disks and Jiffy points resulted in the best Ra values for the majority of the materials tested
    corecore