164 research outputs found
Effect of temperature on the mechanical properties of X5CrNi18-9 steel
The results of static tensile tests conducted on a selected steel grade with austenitic matrix are discussed in this paper. The tensile tests were carried out at the following temperatures: 200°, 400° and 700 °C. Under the conditions of the static tensile test, all the samples failed with a characteristic “necking” forming a cup-conical shape. It has been found that with increasing temperature the strength properties decrease and the elongation increases. The microscopic examinations of the fractures showed that they were mostly plastic, and numerous “dimples” were filled with non-metallic inclusions characterized by a globular shape and a size of up to 8 µm
System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector
Reconstruction of the image in Positron Emission Tomographs (PET) requires
the knowledge of the system response kernel which describes the contribution of
each pixel (voxel) to each tube of response (TOR). This is especially important
in list-mode reconstruction systems, where an efficient analytical
approximation of such function is required. In this contribution, we present a
derivation of the system response kernel for a novel 2D strip PET.Comment: 10 pages, 2 figures; Presented at Symposium on applied nuclear
physics and innovative technologies, Cracow, 03-06 June 201
Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators
Compressive Sensing theory says that it is possible to reconstruct a measured
signal if an enough sparse representation of this signal exists in comparison
to the number of random measurements. This theory was applied to reconstruct
signals from measurements of plastic scintillators. Sparse representation of
obtained signals was found using SVD transform.Comment: 7 pages, 3 figures; Presented at Symposium on applied nuclear physics
and innovative technologies, Cracow, 03-06 June 201
A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays
All of the present methods for calibration and monitoring of TOF-PET scanner
detectors utilize radioactive isotopes such as e.g. Na or Ge,
which are placed or rotate inside the scanner. In this article we describe a
novel method based on the cosmic rays application to the PET calibration and
monitoring methods. The concept allows to overcome many of the drawbacks of the
present methods and it is well suited for newly developed TOF-PET scanners with
a large longitudinal field of view. The method enables also monitoring of the
quality of the scintillator materials and in general allows for the continuous
quality assurance of the PET detector performance.Comment: 10 pages, 7 figure
Determination of the map of efficiency of the J-PET detector with the GATE package
A novel PET detector consisting of strips of polymer scintillators is being
developed by the J-PET Collaboration. The map of efficiency and the map of
geometrical acceptance of the 2-strip J-PET scanner are presented. Map of
efficiency was determined using the Monte Carlo simulation software GATE based
on GEANT4. Both maps were compared using method based on the chi2 test.Comment: 14 pages, 9 figures, proceeding from conference Symposium on Positron
Emission Tomography: http://koza.if.uj.edu.pl/pet-symposium-2013
- …