78 research outputs found

    Anuloplastia mitral com tira de pericárdio bovino resultados de 18 anos

    Get PDF
    PURPOSE: Prosthetic annuloplasty rings are currently used in mitral reconstruction. Posterior annuloplasty with a bovine pericardial strip is a technique largely used in the Heart Institute of University of São Paulo Medical School. The purpose of the study was to analyze the late results of mitral valve repair with posterior annuloplasty using a bovine pericardial strip. METHODS: Between January 1984 and December 2002, 273 patients underwent mitral valve repair with posterior pericardial annuloplasty in the Heart Institute of University of São Paulo Medical School. One hundred and forty four (52.7%) were women and ages ranged between 1 and 76 years (38.3 ± 21.1). Rheumatic fever was present in 52.0% of the patients. Associated techniques were employed in 26.0% of the patients, and the most frequent was chordal shortening (9.2%). RESULTS: Hospital mortality was 3.3% (9 patients), with the major cause being low cardiac output (6 patients). Actuarial survival was 55.1% ± 16.8% in 18 years. During the 18-year follow-up: patients were free from the following: reoperation (59.1% ±± 13.9%, (percent +/- Standard Error), thromboembolism (97.4% ± 2.3%), hemolysis (99.2% ± 0.2%), and endocarditis (99.6% ± 1.0%). In the late follow-up period, 83.9% were classified as New York Heart Association functional class I. CONCLUSIONS: Late results with mitral valve repair with posterior annuloplasty using a bovine pericardial strip were satisfactory. The technique is feasible, reproducible, and cost effective.OBJETIVO: Anéis protéticos para anuloplastia são usados nas plásticas da valva mitral de forma rotineira. A anuloplastia posterior com tira de pericárdio bovino é uma técnica largamente utilizada no Instituto do Coração - HC - FMUSP. O objetivo deste estudo foi analisar os resultados tardios da plástica da valva mitral com a utilização desta técnica na nossa instituição. MÉTODOS: Entre janeiro de 1984 e dezembro de 2002, 273 pacientes foram submetidos a plástica da valva mitral com anuloplastia posterior no Instituto do Coração. Foram excluídos os pacientes submetidos a outros procedimentos no anel posterior. Cento e quarenta e quatro (52,7%) eram do sexo feminino e a idade variou entre 1 e 76 anos (média: 38,3 ± 21,1 anos). Em 52% dos pacientes, havia história de febre reumática. Técnicas associadas para reconstrução valvar foram empregadas em 26% dos casos, sendo a mais utilizada, o encurtamento de cordas (9,2%). RESULTADOS: A mortalidade hospitalar foi de 3,3% (9 casos). A principal causa de óbito foi baixo débito cardíaco (6 pacientes). A sobrevida actuarial foi de 55,1 ± 16,8% (percent +/- Standard Error) em 18 anos, sobrevida livre de reoperação, tromboembolismo, hemólise e endocardite foram respectivamente de 59,1 ± 13,9%, 97,4 ± 2,3%, 99,2 ± 0,2%, 99,6 ± 1,0% em 18 anos. No seguimento tardio, 83,9% dos pacientes se encontravam em classe funcional I (NYHA). CONCLUSÕES: Concluímos que os resultados tardios foram satisfatórios. A técnica é fácil, reprodutível e de baixo custo

    Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis

    Get PDF
    ABSTRACT Objective: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). Methods: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with symptomatic, moderate, or severe valve disease who underwent BVP implants in the timeframe from 2013 to 2020 at three Brazilian institutions. Death, valve-related adverse events (AEs), functional recovery, and hemodynamic performance were evaluated at the hospital, at discharge, and six months and one year later. Primary analysis compared late (> 30 days after implant) linearized rates of valve-related AEs, such as thromboembolism, valve thrombosis, major hemorrhage, major paravalvular leak, and endocarditis, following objective performance criteria (OPC). Analysis was performed to include at least 400 valve-years for each valve position (aortic and mitral) for complete comparisons to OPC. Kaplan-Meier survival and major adverse cardiovascular and cerebrovascular event analyses were also performed. Results: This retrospective study analyzed follow-up data collected from 903 patients (834.2 late patient-years) who have undergone surgery for 455 isolated aortic valve replacement (50.4%), 382 isolated mitral valve replacement (42.3%), and 66 combined valve replacement or other intervention (7.3%). The linearized rates of valve-related AEs were < 2 × OPC. One-year survival rates were 95.1% and 92.7% for aortic and mitral valve replacement, respectively. This study demonstrated an improvement in the New York Heart Association classification from baseline and hemodynamic performance within an expected range. Conclusion: According to this analysis, BVP meets world standards for safety and clinical efficacy

    Estudo da resistência à tração das cordas da valva mitral

    Get PDF
    OBJECTIVE: To determinate the extension and the resistance of the primary mitral valve chordae tendineae when submitted to traction. The importance of keeping the integrity of papillary muscle, chordae tendineae, and mitral valve cuspid when the replacement of this valve occurs is clear, but the knowledge of the maximum resistance that a primary tendinea chorda can withstand is not known. METHODS: Eight hearts were dissected, and one hundred and thirty two primary human chordae tendineae were measured (length and thickness) and submitted to traction under controlled conditions so that the absolute resistance, resistance relative to thickness (relative resistance), and elongation could be measured. RESULTS: The correlation between the elongation at the moment of rupture and the thickness was equal to 1.54 + 17.02 x thickness (P = 0.026); and to absolute resistance was equal to 0.95 + 1.42 x resistance (P < 0.001); and to the resistance relative to thickness (relative resistance) was equal to 1.95 + 0.08 x relative resistance (P = 0.009). The correlation between the absolute resistance and the thickness was equal to 0.26 + 14.53 x thickness (P < 0.001). CONCLUSION: The resistance of primary mitral valve chordae tendineae is associated with its thickness and elongation at the moment of rupture, but is not associated with the length. The elongation at the moment of rupture shows a relationship with the resistance relative to thickness (relative resistance) and with the thickness of the primary chordae tendineae, but not with the length of the chordae tendineae.OBJETIVO: Determinar o alongamento e a resistência à tração das cordas tendíneas primárias humanas da valva mitral cardíaca. Sabe-se da importância de se manter a integridade do músculo papilar, corda tendínea e cúspide da valva mitral, quando da substituição desta valva, mas não se tem conhecimento da resistência máxima que uma corda tendínea primaria pode sofrer resistência máxima que uma corda tendínea apresenta. MÉTODO: Foram dissecados 8 corações que permitiram a tração de cento e trinta e duas cordas tendíneas primárias humanas. Foram dissecados 8 corações que permitiram a tração de cento e trinta e duas cordas tendíneas primárias humanas, as quais foram medidas (comprimento e espessura) e submetidas a trações em condições controladas, e assim a resistência absoluta, a resistência relativa a espessura (resistência relativa) e o alongamento puderam ser medidos. RESULTADOS: A correlação entre alongamento no momento da ruptura e espessura foi igual a 1,54 + 17,02*espessura (p=0,026); e à resistência absoluta foi igual a 0,95 + 1,42*resistência (

    Does the coronary disease increase the hospital mortality in patients with aortic stenosis undergoing valve replacement?

    Get PDF
    OBJETIVOS: Com o aumento da expectativa de vida nas últimas décadas, tem-se um aumento concomitante da prevalência da estenose aórtica degenerativa e da doença aterosclerótica arterial coronária. O presente estudo visa avaliar a influência da doença aterosclerótica arterial coronária crítica em pacientes portadores de estenose aórtica submetidos ao implante isolado de prótese valvar ou combinado à revascularização do miocárdio. MÉTODOS: No período de janeiro de 2001 a março de 2006, foram analisados 448 pacientes submetidos ao implante isolado de prótese valvar aórtica (Grupo I) e 167 pacientes submetidos à substituição valvar aórtica combinada à revascularização do miocárdio (Grupo II). As variáveis pré e intra-operatórias eleitas para análise foram: sexo, idade, índice de massa corpórea, acidente vascular cerebral, diabete melito, doença pulmonar obstrutiva crônica, febre reumática, hipertensão arterial sistêmica, endocardite, infarto agudo do miocárdio e tabagismo, fração de ejeção do ventrículo esquerdo, doença aterosclerótica arterial coronária crítica, fibrilação atrial crônica, operação valvar aórtica prévia (conservadora), classe funcional de insuficiência cardíaca congestiva, valor sérico de creatinina, colesterol total, tamanho da prótese utilizada, extensão e número de anastomoses distais da revascularização do miocárdio realizada, tempos de circulação extracorpórea de pinçamento aórtico. No estudo estatístico empregou-se análise univariada multivariada. RESULTADOS: A mortalidade hospitalar foi 14,3% (64 óbitos) no Grupo I, sendo 14,5% (58 óbitos) nos pacientes sem doença aterosclerótica arterial coronária crítica associada (Grupo IB) e 12,8% (6 óbitos) nos que apresentavam essa associação (Grupo IA). A mortalidade hospitalar no Grupo II foi 17,6% (29 óbitos), sendo 16,1% (20 óbitos) nos pacientes submetidos à substituição valvar aórtica combinada à revascularização completa do miocárdio (Grupo IIA) e 20,9% (nove óbitos) nos com revascularização incompleta do miocárdio (Grupo IIB). CONCLUSÕES: Nos pacientes submetidos à substituição valvar aórtica isolada, a presença de doença aterosclerótica arterial coronária crítica associada, em pelo menos duas artérias, influenciou a mortalidade hospitalar. Nos pacientes submetidos ao tratamento cirúrgico combinado, o número de artérias coronárias com doença aterosclerótica crítica e a extensão da revascularização do miocárdio (RM completa ou incompleta), não influenciaram a mortalidade hospitalar, mas a realização de mais de três anastomoses distais interferiu.OBJECTIVES: With the increase in life expectancy occurred in recent decades, it has been noted the concomitant increase in the prevalence of aortic stenosis and degenerative disease of atherosclerotic coronary artery. This study aims to evaluate the influence of atherosclerotic coronary artery disease in patients with critical aortic stenosis undergoing isolated or combined implant valve prosthesis and coronary artery by pass grafting. METHODS: In the period of January 2001 to March 2006, there were analyzed 448 patients undergoing isolated implant aortic valve prosthesis (Group I) and 167 patients undergoing aortic valve prosthesis implant combined with coronary artery bypass grafting (Group II). Pre- and intra-operative variables elected for analysis were: age, gender, body mass index, stroke, diabetes mellitus, chronic obstructive pulmonary disease, rheumatic fever, hypertension, endocarditis, acute myocardial infarction, smoking, Fraction of the left ventricular ejection, critical atherosclerotic coronary artery disease, chronic atrial fibrillation, aortic valve operation prior (conservative), functional class of congestive heart failure, value serum creatinine, total cholesterol, size of the prosthesis used, length and number of distal anastomoses held in myocardial revascularization, duration of cardiopulmonary bypass and aortic clamping time. The statistical study employed invariant and multivariate analysis. RESULTS: Hospital mortality was 14.3% (64 deaths) in Group I, and 14.5% (58 deaths) in patients with atherosclerotic coronary artery disease associated criticism (Group IB) and 12.8% (six deaths) in which had this association (Group IA). Hospital mortality in Group II was 17.6% (29 deaths), and 16.1% (20 deaths) in patients undergoing implantation of prosthetic aortic valve combined to complete myocardial revascularization (Group II) and 20.9% (nine deaths) in the myocardial revascularization with incomplete (Group IIB). CONCLUSIONS: In patients undergoing implant isolated from aortic valve prosthesis, the presence of atherosclerotic coronary artery disease associated critical in at least two arteries, influenced the hospital mortality. In patients undergoing surgical treatment combined the number of coronary arteries with critical atherosclerotic disease and extent of coronary artery bypass grafting (complete or incomplete), did not affect the hospital mortality, but the realization of more than three anastomoses in the distal myocardial revascularization interfered

    Raman spectroscopy for diagnosis of calcification in human heart valves 1

    Get PDF
    Abstract. Near-Infrared Raman Spectroscopy (NIRS) has an excellent potential for a rapid, a less invasive and real time diagnosis of various human diseases. The objective of the present study was to apply NIRS for diagnosis of human heart valves and to develop a feasible algorithm to classify the valvular lesions. For Raman studies, a Ti:sapphire laser pumped by an argon laser provided 830 nm excitation. A spectrograph in conjunction with a liquid N2-cooled CCD detected Raman spectra. A total of 97 fragments of human heart valves were scanned and Raman results were compared with histopathology. Spectra were randomly separated into training and prospective groups. Raman data along with Principal Components Analysis (PCA) and Mahalanobis distance were used to model an algorithm for tissue classification, into two categories: normal (N), and calcified (C) heart valves. It has been found that, for N valves, the algorithm has sensitivities of 95%, 100% and specificities of 100%, 100% for training and prospective groups, respectively. For C valves the algorithm provided sensitivities of 100 and 100% and specificities of 95 and 100% for training and prospective groups, respectively. In conclusion, an algorithm has been developed and successfully applied for NIRS diagnosis of human heart valves with high sensitivities and specificities

    Mitral valve repair in rheumatic patients with mitral insuficiency: twenty years of techniques and results

    Get PDF
    OBJETIVO: A plástica da valva mitral em pacientes reumáticos permanece um desafio. O objetivo deste estudo é analisar a técnica e os resultados da plástica da valva mitral em pacientes com insuficiência mitral reumática. MÉTODOS: Foram analisados, retrospectivamente, 330 pacientes portadores de insuficiência mitral reumática submetidos à plástica da valva mitral no Instituto do Coração do HC-FMUSP, entre 1985 e 2005. A idade média foi de 26,9 ± 15,4 anos e 57,6% dos pacientes eram do sexo feminino. No pré-operatório, 39,5% dos pacientes estavam em classe funcional IV. As técnicas de plástica mais comumente utilizadas foram a anuloplastia posterior com tira de pericárdio bovino em 48,4% dos pacientes e a anuloplastia com anel de Carpentier em 22,6%. As técnicas associadas foram empregadas em 55,2% dos pacientes, sendo as mais comuns: encurtamento de cordas (20%) e papilarotomias múltiplas (17,8%). Plástica da valva tricúspide (26,7%) e substituição da valva aórtica (27,2%) foram os procedimentos associados mais frequentes. RESULTADOS: A mortalidade hospitalar foi 0,9% (três pacientes), sendo dois deles crianças em atividade reumática. As taxas linearizadas de tromboembolismo, endocardite, reoperação e óbito tardio foram de 0,2%, 0,2%, 3,5% e 0,5% pacientes-ano, respectivamente. A sobrevida actuarial foi de 86,4 ± 6,6% em 20 anos. A curva livre de reoperação foi de 30,3 ± 11,1% em 20 anos. CONCLUSÕES: A plástica da valva mitral em pacientes reumáticos é uma técnica factível na correção da insuficiência mitral, com baixa mortalidade operatória.OBJECTIVE: Mitral valve repair in rheumatic patients is still a challenge. The purpose of this study is to analyze the results of mitral valve repair in rheumatic patients in the Heart Institute University of Sao Paulo Medical School. METHODS: Were analyzed retrospectively, between 1985 and 2005, 330 patients submitted to mitral valve repair in the Heart Institute of São Paulo. The mean age was 26.9 ± 15.4 years and 57.6% were female. According do clinical evaluation, 39.5% of patients were in NYHA functional class IV. The most common techniques employed were bovine pericardial strip annuloplasty in 48.4% patients and Carpentier ring annuloplasty in 22.6%. Shortening of chordae (20%) and papillary muscle splitting (17.8%) were the most common associated techniques performed. Tricuspid valve repair (26.7%) and aortic valve replacement (27.2%) were the most common associated procedures. RESULTS: The hospital mortality was 0.9% (three patients), two of them in children with active rheumatic fever. Linearized rates of thromboembolism, endocardite, reoperation and late death were 0.2%, 0.2%, 3.5% and 0.5% patients-year, respectively. Actuarial survival in 20 years was 86.4 ± 6.6%. Freedom from reoperation in 20 years was 30.3 ± 11.1%. CONCLUSION: Mitral valve conservative surgery in rheumatic patients is a feasible procedure with low operative mortality

    Mitral valve repair by Double Teflon technique: cardiac remodeling analysis by tridimensional echocardiography

    Get PDF
    INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a insuficiência mitral, porém a literatura é escassa em relação ao comportamento do átrio e ventrículo esquerdos após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, por meio da ecocardiografia tridimensional. MÉTODOS: Foram incluídos 14 pacientes com insuficiência mitral mixomatosa, submetidos à plastia mitral pela técnica de Duplo Teflon. Treze pacientes encontravam-se em classe III/IV. Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante P<0,05. RESULTADOS: A análise dos volumes sistólicos, atrial e ventricular demonstrou redução volumétrica significativa entre POI e 1 ano (P=0,028 e P=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram redução significativa no POI (P<0,001 e P=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (P<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: Os pacientes submetidos à plastia valvar mitral por meio da técnica de Duplo Teflon apresentaram remodelamento reverso do átrio esquerdo e do ventrículo esquerdo. Esta redução nos volumes cavitários esteve associada à melhora da função atrial esquerda durante o estudo.INTRODUCTION: Mitral valve repair is the treatment of choice to correct mitral insufficiency. Although the literature related to left atrial and ventricular behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: To analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. METHODS: Were included 14 patients with mixomatous mitral valve insufficiency that were submitted to mitral valve repair with the Double Teflon technique. Of them, 13 patients were in class III/IV. Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant P < 0.05. RESULTS: The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (P=0.028 and P=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (P <0.001 and P =0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (P<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Patients submitted to mitral valve repair by the Double Teflon technique demonstrated a left atrial and ventricle reverse remodeling. These reductions were associated with an improvement in left atrial function during the study.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP
    corecore