6,854 research outputs found
An a posteriori error analysis of a mixed finite element Galerkin approximation to second order linear parabolic problems
In this article, a posteriori error estimates are derived for a mixed finite element Galerkin approximation to second order linear parabolic initial and boundary value problems. Using mixed elliptic reconstruction method, a posteriori error estimates in and -norms with optimal order of convergence for the solution as well as its flux are proved for the semidiscrete scheme. Finally, based on backward Euler method, a completely discrete scheme is analyzed and a posteriori bounds are derived, which improves earlier results on a posteriori estimates for mixed parabolic problems
A priori error estimates for the optimal control of laser surface hardening of steel
A priori error estimates for the optimal control of laser surface hardening of stee
An hp-Local Discontinuous Galerkin method for Parabolic\ud Integro-Differential Equations
In this article, a priori error analysis is discussed for an hp-local discontinuous Galerkin (LDG) approximation to a parabolic integro-differential equation. It is shown that the L2 -norm of the gradient and the L2 -norm of the potential are optimal in the discretizing parameter h and suboptimal in the degree of polynomial p. Due to the presence of the integral term, an introduction of an expanded mixed type Ritz-Volterra projection helps to achieve optimal estimates. Further, it is observed that a negative norm estimate of the gradient plays a crucial role in our convergence analysis. As in the elliptic case, similar results on order of convergence are established for the semidiscrete method after suitably modifying the numerical fluxes. The optimality of these theoretical results is tested in a series of numerical experiments on two dimensional domains
Optimal error estimates of a mixed finite element method for\ud parabolic integro-differential equations with non smooth initial data
In this article, a new mixed method is proposed and analyzed for parabolic integro-differential equations (PIDE) with nonsmooth initial data. Compared to mixed methods for PIDE, the present method does not bank on a reformulation using a resolvent operator. Based on energy arguments and without using parabolic type duality technique, optimal L2-error estimates are derived for semidiscrete approximations, when the initial data is in L2. Due to the presence of the integral term, it is, further, observed that estimate in dual of H(div)-space plays a role in our error analysis. Moreover, the proposed analysis follows the spirit of the proof technique used for deriving optimal error estimates of finite element approximations to PIDE with smooth data and therefore, it unifies both the theories, i.e., one for smooth data and other for nonsmooth data. Finally, the proposed analysis can be easily extended to other mixed method for PIDE with rough initial data and provides an improved result
Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays
We have studied the performance of two different types of front-end systems
for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels
multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64
pixels of which corresponds to the anode pixels of
H8500. One of the system is based on commercial ASIC chips in order to readout
every anode. The others are based on resistive charge divider network between
anodes to reduce readout channels. In both systems, each pixel (6mm) was
clearly resolved by flood field irradiation of Cs. We also investigated
the energy resolution of these systems and showed the performance of the
cascade connection of resistive network between some PMTs for large area
detectors.Comment: 9 pages, 6 figures, proceedings of the 7th International Workshop on
Radiation Imaging Detectors (IWORID7), submitted to NIM
Cholesterol homeostasis: a key to prevent or slow down neurodegeneration
Neurodegeneration, a common feature for many brain disorders, has severe consequences on the mental and physical health of an individual. Typically human neurodegenerative diseases are devastating illnesses that predominantly affect elderly people, progress slowly, and lead to disability and premature death; however they may occur at all ages. Despite extensive research and investments, current therapeutic interventions against these disorders treat solely the symptoms. Therefore, since the underlying mechanisms of damage to neurons are similar, in spite of etiology and background heterogeneous, it will be of interest to identify possible trigger point of neurodegeneration enabling development of drugs and/or prevention strategies that target many disorders simultaneously. Among the factors that have been identified so far to cause neurodegeneration, failures in cholesterol homeostasis are indubitably the best investigated. The aim of this review is to critically discuss some of the main results reported in the recent years in this field mainly focusing on the mechanisms that, by recovering perturbations of cholesterol homeostasis in neuronal cells, may correct clinically relevant features occurring in different neurodegenerative disorders and, in this regard, also debate the current potential therapeutic interventions
Black-Hole Bombs and Photon-Mass Bounds
Generic extensions of the standard model predict the existence of ultralight
bosonic degrees of freedom. Several ongoing experiments are aimed at detecting
these particles or constraining their mass range. Here we show that massive
vector fields around rotating black holes can give rise to a strong
superradiant instability which extracts angular momentum from the hole. The
observation of supermassive spinning black holes imposes limits on this
mechanism. We show that current supermassive black hole spin estimates provide
the tightest upper limits on the mass of the photon (mv<4x10^{-20} eV according
to our most conservative estimate), and that spin measurements for the largest
known supermassive black holes could further lower this bound to mv<10^{-22}
eV. Our analysis relies on a novel framework to study perturbations of rotating
Kerr black holes in the slow-rotation regime, that we developed up to second
order in rotation, and that can be extended to other spacetime metrics and
other theories.Comment: 5 pages, 2 figures. References added. Matches published versio
Development of Large area Gamma-ray Camera with GSO(Ce) Scintillator Arrays and PSPMTs
We have developed a position-sensitive scintillation camera with a large area
absorber for use as an advanced Compton gamma-ray camera. At first we tested
GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under
various conditions: the method of surface polishing, the concentration of Ce,
and co-doping Zr. As a result, we chose the GSO(Ce) crystals doped with only
0.5 mol% Ce, and its surface polished by chemical etching as the scintillator
of our camera. We also made a 1616 cm scintillation camera which
consisted of 9 position-sensitive PMTs (PSPMTs Hamamatsu flat-panel H8500), the
each of which had 88 anodes with a pitch of 6 mm and coupled to
88 arrays of pixelated 613 mm GSO(Ce) scintillators.
For the readout system of the 576 anodes of the PMTs, we used chained resistors
to reduce the number of readout channels down to 48 to reduce power
consumption. The camera has a position resolution of less than 6mm and a
typical energy resolution of 10.5% (FWHM) at 662 keV at each pixel in a large
area of 1616 cm. %to choose the best scintillator for our project.
Furthermore we constructed a 1616 array of 313 mm
pixelated GSO(Ce) scintillators, and glued it to a PMT H8500. This camera had
the position resolution of less than 3mm, over an area of 55 cm,
except for some of the edge pixels; the energy resolution was typically 13%
(FWHM) at 662 keV.Comment: Proceedings of PSD7 appear in NIM
A multi-layer edge-on single photon counting silicon microstrip detector for innovative techniques in diagnostic radiology
A three-layer detector prototype, obtained by stacking three edge-on single photon counting silicon microstrip detectors, has been developed and widely tested. This was done in the framework of the Synchrotron Radiation for Medical Physics/Frontier Radiology (SYRMEP/FRONTRAD) collaboration activities, whose aim is to improve the quality of mammographic examinations operating both on the source and on the detector side. The active surface of the device has been fully characterized making use of an edge-scanning technique and of a well-collimated laminar synchrotron radiation beam. The obtained data (interlayer distances, channel correspondence, etc.) have then been used to combine information coming from each detector layer, without causing any loss in spatial and contrast resolution of the device. Contrast and spatial resolution have also been separately evaluated for each detector layer. Moreover, imaging techniques (phase contrast, refraction, and scatter imaging), resulting in an increased visibility of low absorbing details, have been implemented, and their effectiveness has been tested on a biological sample. Finally, the possibility of simultaneously acquiring different kind of images with the different detector layers is discussed. This would result in maximizing the information extracted from the sample, while at the same time the high absorption efficiency of the detector device would allow a low dose delivery
- …
