125 research outputs found

    Multimodal X-ray imaging of nanocontainer-treated macrophages and calcium distribution in the perilacunar bone matrix

    Get PDF
    Studies of biological systems typically require the application of several complementary methods able to yield statistically-relevant results at a unique level of sensitivity. Combined X-ray fluorescence and ptychography offer excellent elemental and structural imaging contrasts at the nanoscale. They enable a robust correlation of elemental distributions with respect to the cellular morphology. Here we extend the applicability of the two modalities to higher X-ray excitation energies, permitting iron mapping. Using a long-range scanning setup, we applied the method to two vital biomedical cases. We quantified the iron distributions in a population of macrophages treated with Mycobacterium-tuberculosis-targeting iron-oxide nanocontainers. Our work allowed to visualize the internalization of the nanocontainer agglomerates in the cytosol. From the iron areal mass maps, we obtained a distribution of antibiotic load per agglomerate and an average areal concentration of nanocontainers in the agglomerates. In the second application we mapped the calcium content in a human bone matrix in close proximity to osteocyte lacunae (perilacunar matrix). A concurrently acquired ptychographic image was used to remove the mass-thickness effect from the raw calcium map. The resulting ptychography-enhanced calcium distribution allowed then to observe a locally lower degree of mineralization of the perilacunar matrix

    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    Multilevel factors are associated with immunosuppressant nonadherence in heart transplant recipients: The international BRIGHT study

    Get PDF
    Factors at the level of family/healthcare worker, organization, and system are neglected in medication nonadherence research in heart transplantation (HTx). The 4-continent, 11-country cross-sectional Building Research Initiative Group: Chronic Illness Management and Adherence in Transplantation (BRIGHT) study used multistaged sampling to examine 36 HTx centers, including 36 HTx directors, 100 clinicians, and 1397 patients. Nonadherence to immunosuppressants\u2014defined as any deviation in taking or timing adherence and/or dose reduction\u2014was assessed using the Basel Assessment of Adherence to Immunosuppressive Medications Scale \ua9 (BAASIS \ua9 ) interview. Guided by the Integrative Model of Behavioral Prediction and Bronfenbrenner's ecological model, we analyzed factors at these multiple levels using sequential logistic regression analysis (6 blocks). The nonadherence prevalence was 34.1%. Six multilevel factors were associated independently (either positively or negatively) with nonadherence: patient level: barriers to taking immunosuppressants (odds ratio [OR]: 11.48); smoking (OR: 2.19); family/healthcare provider level: frequency of having someone to help patients read health-related materials (OR: 0.85); organization level: clinicians reporting nonadherent patients were targeted with adherence interventions (OR: 0.66); pickup of medications at physician's office (OR: 2.31); and policy level: monthly out-of-pocket costs for medication (OR: 1.16). Factors associated with nonadherence are evident at multiple levels. Improving medication nonadherence requires addressing not only the patient, but also family/healthcare provider, organization, and policy levels

    Clinical impact and 'natural' course of uncorrected tricuspid regurgitation after implantation of a left ventricular assist device: an analysis of the European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation. METHODS: The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. RESULTS: A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06-1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. CONCLUSIONS: Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progr

    Validation of the patient assessment of chronic illness care (PACIC) short form scale in heart transplant recipients: The international cross-sectional bright study

    Get PDF
    Background: Transplant recipients are chronically ill patients, who require lifelong follow-up to manage co-morbidities and prevent graft loss. This necessitates a system of care that is congruent with the Chronic Care Model. The eleven-item self-report Patient Assessment of Chronic Illness Care (PACIC) scale assesses whether chronic care is congruent with the Chronic Care Model, yet its validity for heart transplant patients has not been tested. Methods: We tested the validity of the English version of the PACIC, and compared the similarity of the internal structure of the PACIC across English-speaking countries (USA, Canada, Australia and United Kingdom) and across six languages (French, German, Dutch, Spanish, Italian and Portuguese). This was done using data from the cross-sectional international BRIGHT study that included 1378 heart transplant patients from eleven countries across 4 continents. To test the validity of the instrument, confirmatory factor analyses to check the expected unidimensional internal structure, and relations to other variables, were performed. Results: Main analyses confirmed the validity of the English PACIC version for heart transplant patients. Exploratory analyses across English-speaking countries and languages also confirmed the single factorial dimension, except in Italian and Spanish. Conclusion: This scale could help healthcare providers monitor level of chronic illness management and improve transplantation care. Trial registration: Clinicaltrials.gov ID: NCT01608477, first patient enrolled in March 2012, registered retrospectively: May 30, 2012

    2019 EACTS Expert Consensus on long-term mechanical circulatory support

    Get PDF
    Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many-sometimes contradictory-observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device

    Die Herzleistungsschwäche ist des Teufels

    No full text
    • …
    corecore