22,150 research outputs found

    Nanocrystalline diamond film for biosensor applications

    Get PDF
    In this study, we have developed a novel capacitive biosensor based oil interdigitated gold nanodiamond (GID-NCD) electrode for detection of C-reactive protein (CRP) antigen. CRP is one of the plasma proteins known as acute-phase proteins and its levels rise dramatically during inflammatory processes occurring in the body. It has been reported that CRP in serum can be used for risk assessment of cardiovascular diseases. The antibodies immobilization were confirmed by Fourier transform spectroscopy (FTIR) and contact angle measurements. In this capacitive biosensor, nanocrystalline diamond acting as a dielectric layer between the electrodes. The CRP antigen detection was performed by capacitive/dielectric-constant measurements. Our results showed that the response of NCD-based capacitive-based biosensor for CRP antigen was dependent on both concentration (25-800 ng/ml) as well as frequency (50-350 MHz). Furthermore, using optimized conditions, the biosensors developed in this study can be potentially used for detection of elevated level of risk markers protein in suspected subjects for early diagnosis of disease

    A novel interdigitated capacitor based biosensor for detection of cardiovascular risk marker

    Get PDF
    C-reactive protein (CRP) is a potential biomarker whose elevated levels in humans determine cardiovascular disease risk and inflammation. In this study, we have developed a novel capacitive biosensor for detection of CRP-antigen using capacitor with interdigitated gold (GID) electrodes on nanocrystalline diamond (NCD) surface. The NCD surface served as a dielectric layer between the gold electrodes. GID-surface was functionalized by antibodies and the immobilization was confirmed by Fourier transform spectroscopy (FT-IR) and contact angle measurements. The CRP-antigen detection was performed by capacitive/dielectric-constant measurements. The relaxation time and polarizability constants were estimated using Cole-Cole model. Our results showed that the relaxation time constant (tau) of only CRP-antibody was within 10(-16)-10(-13) s, which was increased to 10(-11) s after the incubation with CRP-antigen, suggesting that the CRP-antigen was captured by the antibodies on GID-surface. In addition, polarizability constant(m) of CRP was also increased upon incubation with increasing concentration of CRP-antigen. Our results showed that the response of GID-NCD-based capacitive biosensor for CRP-antigen was dependent on both concentration (25-800 ng/ml) as well as frequency (50-350 MHz). Furthermore, using optimized conditions, the GID-NCD based capacitive biosensor developed in this study can potentially be used for detection of elevated levels of protein risk markers in suspected subjects for early diagnosis of disease

    More similarities than differences: An international comparison of CVD mortality and risk factors in women

    Full text link
    In this article we describe global cardiovascular risk factor trends in women, both physiological and behavioral, in order to improve the understanding of cardiovascular health of women. Our aim in presenting this information is to inform interventions and policies to improve the cardiovascular health of women. Although differences are apparent between developing and developed countries, a range of commonalities exist that allow a global approach to improving women's health. A multifaceted approach considering physiological, social, economic, and political determinants is critical to improve the cardiovascular health outcomes of women

    Machine Learning and Irresponsible Inference: Morally Assessing the Training Data for Image Recognition Systems

    Get PDF
    Just as humans can draw conclusions responsibly or irresponsibly, so too can computers. Machine learning systems that have been trained on data sets that include irresponsible judgments are likely to yield irresponsible predictions as outputs. In this paper I focus on a particular kind of inference a computer system might make: identification of the intentions with which a person acted on the basis of photographic evidence. Such inferences are liable to be morally objectionable, because of a way in which they are presumptuous. After elaborating this moral concern, I explore the possibility that carefully procuring the training data for image recognition systems could ensure that the systems avoid the problem. The lesson of this paper extends beyond just the particular case of image recognition systems and the challenge of responsibly identifying a person’s intentions. Reflection on this particular case demonstrates the importance (as well as the difficulty) of evaluating machine learning systems and their training data from the standpoint of moral considerations that are not encompassed by ordinary assessments of predictive accuracy

    Shannon entropies of atomic structure factors, off-diagonal order and electron correlation

    Full text link
    Shannon entropies of one- and two-electron atomic structure factors in the position and momentum representations are used to examine the behavior of the off-diagonal elements of density matrices with respect to the uncertainty principle and to analyze the effects of electron correlation on off-diagonal order. We show that electron correlation induces off-diagonal order in position space which is characterized by larger entropic values. Electron correlation in momentum space is characterized by smaller entropic values as information is forced into regions closer to the diagonal. Related off-diagonal correlation functions are also discussed

    Review on carbon-derived, solid-state, micro and nano sensors for electrochemical sensing applications

    Get PDF
    The aim of this review is to summarize the most relevant contributions in the development of electrochemical sensors based on carbon materials in the recent years. There have been increasing numbers of reports on the first application of carbon derived materials for the preparation of an electrochemical sensor. These include carbon nanotubes, diamond like carbon films and diamond film-based sensors demonstrating that the particular structure of these carbon material and their unique properties make them a very attractive material for the design of electrochemical biosensors and gas sensors. Carbon nanotubes (CNT) have become one of the most extensively studied nanostructures because of their unique properties. CNT can enhance the electrochemical reactivity of important biomolecules and can promote the electron-transfer reactions of proteins (including those where the redox center is embedded deep within the glycoprotein shell). In addition to enhanced electrochemical reactivity, CNT-modified electrodes have been shown useful to be coated with biomolecules (e.g., nucleic acids) and to alleviate surface fouling effects (such as those involved in the NADH oxidation process). The remarkable sensitivity of CNT conductivity with the surface adsorbates permits the use of CNT as highly sensitive nanoscale sensors. These properties make CNT extremely attractive for a wide range of electrochemical sensors ranging from amperometric enzyme electrodes to DNA hybridization biosensors. Recently, a CNT sensor based fast diagnosis method using non-treated blood assay has been developed for specific detection of hepatitis B virus (HBV) (human liver diseases, such as chronic hepatitis, cirrhosis, and hepatocellular carcinoma caused by hepatitis B virus). The linear detection limits for HBV plasma is in the range 0.5–3.0 μL−1 and for anti- HBVs 0.035–0.242 mg/mL in a 0.1 M NH4H2PO4 electrolyte solution. These detection limits enables early detection of HBV infection in suspected serum samples. Therefore, non-treated blood serum can be directly applied for real-time sensitive detection in medical diagnosis as well as in direct in vivo monitoring. Synthetic diamond has been recognized as an extremely attractive material for both (bio-) chemical sensing and as an interface to biological systems. Synthetic diamond have outstanding electrochemical properties, superior chemical inertness and biocompatibility. Recent advances in the synthesis of highly conducting nanocrystalline-diamond thin films and nano wires have lead to an entirely new class of electrochemical biosensors and bio-inorganic interfaces. In addition, it also combines with development of new chemical approaches to covalently attach biomolecules on the diamond surface also contributed to the advancement of diamond-based biosensors. The feasibility of a capacitive field-effect EDIS (electrolyte-diamond-insulatorsemiconductor) platform for multi-parameter sensing is demonstrated with an O-terminated nanocrystalline-diamond (NCD) film as transducer material for the detection of pH and penicillin concentration. This has also been extended for the label-free electrical monitoring of adsorption and binding of charged macromolecules. One more recent study demonstrated a novel bio-sensing platform, which is introduced by combination of a) geometrically controlled DNA bonding using vertically aligned diamond nano-wires and b) the superior electrochemical sensing properties of diamond as transducer material. Diamond nanowires can be a new approach towards next generation electrochemical gene sensor platforms. This review highlights the advantages of these carbon materials to promote different electron transfer reactions specially those related to biomolecules. Different strategies have been applied for constructing carbon material-based electrochemical sensors, their analytical performance and future prospects are discussed

    On the formation of cyclones and anticyclones in a rotating fluid

    Get PDF
    It is commonly observed that the columnar vortices that dominate the large scales in homogeneous, rapidly rotating turbulence are predominantly cyclonic. This has prompted us to ask how this asymmetry arises. To provide a partial answer to this we look at the process of columnar vortex formation in a rotating fluid and, in particular, we examine how a localized region of swirl (an eddy) can convert itself into a columnar structure by inertial wave propagation. We show that, when the Rossby number (Ro) is small, the vortices evolve into columnar eddies through the radiation of linear inertial waves. When the Rossby number is large, on the other hand, no such column is formed. Rather, the eddy bursts radially outward under the action of the centrifugal force. There is no asymmetry between cyclonic and anticyclonic eddies for these two regimes. However, cyclones and anticyclones behave differently in the intermediate regime of Ro~1. Here we find that the transition from columnar vortex formation to radial bursting occurs at lower values of Ro for anticyclones, with the transition for anticyclones occurring at Ro~0.5, and that for cyclones at Ro~2. Thus, in a homogeneous turbulence experiment conducted at, say, Ro=1, we would expect to see more cyclones than anticyclones. The reason for this asymmetry at Ro~1 is explained

    Non-equilibrium dynamics of gene expression and the Jarzynski equality

    Full text link
    In order to express specific genes at the right time, the transcription of genes is regulated by the presence and absence of transcription factor molecules. With transcription factor concentrations undergoing constant changes, gene transcription takes place out of equilibrium. In this paper we discuss a simple mapping between dynamic models of gene expression and stochastic systems driven out of equilibrium. Using this mapping, results of nonequilibrium statistical mechanics such as the Jarzynski equality and the fluctuation theorem are demonstrated for gene expression dynamics. Applications of this approach include the determination of regulatory interactions between genes from experimental gene expression data

    Preliminary report on IUE spectra of the Crab Nebula

    Get PDF
    The Crab Nebula is marginally observable with the IUE. Observations of the optically brightest filamentary regions, made with IUE in August 1979, show the C IV lambda 1549, He II lambda 1640, and C III lambda 1909 emission lines. The intensities of these lines were compared with the visual wavelength data. It appears that carbon is not overabundant in the Crab; carbon/oxygen is approximately normal and oxygen is slightly scarcer than normal as a fraction of the total mass
    • …
    corecore