516 research outputs found
Properties of the spokes in coaxial and parallel - Plate plasma accelerator
Photographic, magnetic, and spectroscopic study of vortex spokes in coaxial and parallel-plate plasma accelerator
Modern Electronic Techniques Applied to Physics and Engineering
Contains reports on two research projects
A simple soil organic-matter model for biomass data assimilation in community-level carbon contracts
Soil carbon (C) sequestration has been proposed as a transitional win-win strategy to help replenish organic-matter content in depleted agricultural soils and counter increases in atmospheric greenhouse gases. Data assimilation and remote sensing can reduce uncertainty in sequestered C mass estimates, but simple soil organic carbon (SOC) models are required to make operational predictions of tradeable amounts over large, heterogenous areas. Our study compared the performance of RothC26.3 and a reduced compartmental model on an 11-year fertilizer trial in subhumid West Africa. Root mean square error (RMSE) differences of 0.05 Mg C/ha between models on total SOC predictions suggest that for contractual purposes, SOC dynamics can be simulated by a two-pool structure with labile and stable components. Faster (seasonal) and slower (semicentennial and beyond) rates can be approximated by constants as instantaneous and infinite decay. In these systems, simulations indicate that cereal residue incorporation holds most potential for mitigation of transient C loss associated with recent land conversion to agriculture
Modern Electronic Techniques Applied to Physics and Engineering
Contains reports on three research projects
Characterization and adaptation of Caldicellulosiruptor strains to higher sugar concentrations, targeting enhanced hydrogen production from lignocellulosic hydrolysates
Abstract
Background
The members of the genus Caldicellulosiruptor have the potential for future integration into a biorefinery system due to their capacity to generate hydrogen close to the theoretical limit of 4 mol H2/mol hexose, use a wide range of sugars and can grow on numerous lignocellulose hydrolysates. However, members of this genus are unable to survive in high sugar concentrations, limiting their ability to grow on more concentrated hydrolysates, thus impeding their industrial applicability. In this study five members of this genus, C. owensensis, C. kronotskyensis, C. bescii, C. acetigenus and C. kristjanssonii, were developed to tolerate higher sugar concentrations through an adaptive laboratory evolution (ALE) process. The developed mixed population C. owensensis CO80 was further studied and accompanied by the development of a kinetic model based on Monod kinetics to quantitatively compare it with the parental strain.
Results
Mixed populations of Caldicellulosiruptor tolerant to higher glucose concentrations were obtained with C. owensensis adapted to grow up to 80 g/L glucose; other strains in particular C. kristjanssonii demonstrated a greater restriction to adaptation. The C. owensensis CO80 mixed population was further studied and demonstrated the ability to grow in glucose concentrations up to 80 g/L glucose, but with reduced volumetric hydrogen productivities (
Q
H
2
) and incomplete sugar conversion at elevated glucose concentrations. In addition, the carbon yield decreased with elevated concentrations of glucose. The ability of the mixed population C. owensensis CO80 to grow in high glucose concentrations was further described with a kinetic growth model, which revealed that the critical sugar concentration of the cells increased fourfold when cultivated at higher concentrations. When co-cultured with the adapted C. saccharolyticus G5 mixed culture at a hydraulic retention time (HRT) of 20 h, C. owensensis constituted only 0.09–1.58% of the population in suspension.
Conclusions
The adaptation of members of the Caldicellulosiruptor genus to higher sugar concentrations established that the ability to develop improved strains via ALE is species dependent, with C. owensensis adapted to grow on 80 g/L, whereas C. kristjanssonii could only be adapted to 30 g/L glucose. Although C. owensensis CO80 was adapted to a higher sugar concentration, this mixed population demonstrated reduced
Q
H
2
with elevated glucose concentrations. This would indicate that while ALE permits adaptation to elevated sugar concentrations, this approach does not result in improved fermentation performances at these higher sugar concentrations. Moreover, the observation that planktonic mixed culture of CO80 was outcompeted by an adapted C. saccharolyticus, when co-cultivated in continuous mode, indicates that the robustness of CO80 mixed culture should be improved for industrial application
Recommended from our members
Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS
The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatially resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different {sup 235}U to {sup 238}U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing {sup 235}U in depleted, natural, and enriched abundances were analyzed as particle aggregates immobilized in a collodion substrate. The uranium oxide samples were nuclear reference materials (CRMs U0002, U005-A, 129-A, U015, U030-A, and U050) obtained from New Brunswick Laboratory-USDOE
Modern Electronic Techniques Applied to Physics and Engineering
Contains reports on five research projects
PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery
<p>Abstract</p> <p>Background</p> <p>The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH<sub>2</sub>O (ZEEP), associated to a manual bilateral thoracic compression.</p> <p>Aim</p> <p>To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients.</p> <p>Methods</p> <p>15 patients submitted to a coronary artery bypass graft surgery (CABG) were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH<sub>2</sub>O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH<sub>2</sub>O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished.</p> <p>Results</p> <p>The inspiratory peak and plateau pressures increased during the procedure (p < 0.001) compared with other pressures during the assessment periods; however, they were within lung safe limits. The expiratory flow before the procedure were 33 ± 7.87 L/min, increasing significantly during the procedure to 60 ± 6.54 L/min (p < 0.001), diminishing to 35 ± 8.17 L/min at 10 minutes and to 36 ± 8.48 L/min at 30 minutes. Hemodynamic and oxygenation variables were not altered.</p> <p>Conclusion</p> <p>The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.</p
- …