90,477 research outputs found

    Computer aids and human second reading as interventions in screening mammography: two systematic reviews to compare effects on cancer detection and recall rate

    Get PDF
    Background: There are two competing methods for improving the accuracy of a radiologist interpreting screening mammograms: computer aids (CAD) or independent second reading. Methods: Bibliographic databases were searched for clinical trials. Meta-analyses estimated impacts of CAD and double reading on odds ratios for cancer detection and recall rates. Sub-group analyses considered double reading with arbitration. Results: Ten studies compared single reading with CAD to single reading. Seventeen compared double to single reading. Double reading increases cancer detection and recall rates. Double reading with arbitration increases detection rate (CI: 1.02-1.15) and decreases recall rate (CI: 0.92-0.96). CAD does not have a significant effect on cancer detection rate (CI: 0.96-1.13) and increases recall rate (95% CI: 1.09-1.12). However, there is considerable heterogeneity in the impact on recall rate in both sets of studies. Conclusion: The evidence that double reading with arbitration enhances screening is stronger than that for single reading with CAD

    Variational approximations to homoclinic snaking

    Full text link
    We investigate the snaking of localised patterns, seen in numerous physical applications, using a variational approximation. This method naturally introduces the exponentially small terms responsible for the snaking structure, that are not accessible via standard multiple-scales asymptotic techniques. We obtain the symmetric snaking solutions and the asymmetric 'ladder' states, and also predict the stability of the localised states. The resulting approximate formulas for the width of the snaking region show good agreement with numerical results.Comment: 4 pages, 3 figures, submitte

    Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

    Get PDF
    A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission

    Workshop on Moon in Transition: Apollo 14, KREEP, and Evolved Lunar Rocks

    Get PDF
    Lunar rocks provide material for analyzing lunar history and now new evaluation procedures are available for discovering new information from the Fra Mauro highlands rocks, which are different from any other lunar samples. These and other topics were discussed at this workshop, including a new evaluation of the nature and history of KREEP, granite, and other evolved lunar rock types, and ultimately a fresh evaluation of the transition of the moon from its early anorthosite-forming period to its later stages of KREEPy, granitic, and mare magmatism. The summary of presentations and discussion is based on notes taken by the respective summarizers during the workshop

    Selection of neutralizing antibody escape mutants with type A influenza virus HA-specific polyclonal antisera: possible significance for antigenic drift

    Get PDF
    Ten antisera were produced in rabbits by two or three intravenous injections of inactivated whole influenza type A virions. All contained haemagglutination-inhibition (HI) antibody directed predominantly to an epitope in antigenic site B and, in addition, various amounts of antibodies to an epitope in site A and in site D. The ability of untreated antisera to select neutralization escape mutants was investigated by incubating virus possessing the homologous haemagglutinin with antiserum adjusted to contain anti-B epitope HI titres of 100, 1000 and 10000 HIU/ml. Virus-antiserum mixtures were inoculated into embryonated hen's eggs, and progeny virus examined without further selection. Forty percent of the antisera at a titre of 1000 HIU/ml selected neutralizing antibody escape mutants as defined by their lack of reactivity to Mab HC10 (site B), and unchanged reactivity to other Mabs to site A and site D epitopes. All escape mutant-selecting antisera had a ratio of anti-site B (HC10)-epitope antibody[ratio]other antibodies of [gt-or-equal, slanted]2·0[ratio]1. The antiserum with the highest ratio (7·4[ratio]1) selected escape mutants in all eggs tested in four different experiments. No antiserum used at a titre of 10000 HIU/ml allowed multiplication of any virus. All antisera used at a titre of 100 HIU/ml permitted virus growth, but this was wild-type (wt) virus. We conclude that a predominant epitope-specific antibody response, a titre of [gt-or-equal, slanted]1000 HIU/ml, and a low absolute titre of other antibodies ([less-than-or-eq, slant]500 HIU/ml) are three requirements for the selection of escape mutants. None of the antisera in this study could have selected escape mutants without an appropriate dilution factor, so the occurrence of an escape mutant-selecting antiserum in nature is likely to be a rare event

    A microcontroller system for investigating the catch effect: Functional electrical stimulation of the common peroneal nerve

    No full text
    Correction of drop foot in hemiplegic gait is achieved by electrical stimulation of the common peroneal nerve with a series of pulses at a fixed frequency. However, during normal gait, the electromyographic signals from the tibialis anterior muscle indicate that muscle force is not constant but varies during the swing phase. The application of double pulses for the correction of drop foot may enhance the gait by generating greater torque at the ankle and thereby increase the efficiency of the stimulation with reduced fatigue. A flexible controller has been designed around the Odstock Drop Foot Stimulator to deliver different profiles of pulses implementing doublets and optimum series. A peripheral interface controller (PIC) microcontroller with some external circuits has been designed and tested to accommodate six profiles. Preliminary results of the measurements from a normal subject seated in a multi-moment chair (an isometric torque measurement device) indicate that profiles containing doublets and optimum spaced pulses look favourable for clinical use

    Investigation of the influence of a step change in surface roughness on turbulent heat transfer

    Get PDF
    The use is studied of smooth heat flux gages on the otherwise very rough SSME fuel pump turbine blades. To gain insights into behavior of such installations, fluid mechanics and heat transfer data were collected and are reported for a turbulent boundary layer over a surface with a step change from a rough surface to a smooth surface. The first 0.9 m length of the flat plate test surface was roughened with 1.27 mm hemispheres in a staggered, uniform array spaced 2 base diameters apart. The remaining 1.5 m length was smooth. The effect of the alignment of the smooth surface with respect to the rough surface was also studied by conducting experiments with the smooth surface aligned with the bases or alternatively with the crests of the roughness elements. Stanton number distributions, skin friction distributions, and boundary layer profiles of temperature and velocity are reported and are compared to previous data for both all rough and all smooth wall cases. The experiments show that the step change from rough to smooth has a dramatic effect on the convective heat transfer. It is concluded that use of smooth heat flux gages on otherwise rough surfaces could cause large errors
    corecore