28 research outputs found
Characterization of Siloxane-poly(methyl methacrylate) Hybrid Films Obtained on a Tinplate Substrate Modified by the Addition of Organic and Inorganic Acids
Tinplate is used to food packaging and other types of packages. The corrosion resistance of the tinplate has been study due the necessity of an alternative to high environmental impact of chromatization process. Therefore protective coatings as hybrid films base elaborations with different acids are studied to improve the barrier effect against corrosion. The objective of this work is characterize hybrid films deposited on a tinplate from a sol made up of the alkoxide precursors 3-(trimethoxysilylpropyl) methacrylate (TMSM), tetraethoxysilane (TEOS) and poly(methyl methacrylate) (PMMA) together with one of three acids (acetic, hydrochloric or nitric acid) and to verify their action against the corrosion of the substrate. The films were obtained by a dip-coating process and cured for 3 hours at 160 °C. The film hydrophobicity was determined by contact angle measurements, and the morphology was evaluated by SEM. FTIR measurements were performed to characterize the chemical structures of the films. The electrochemical behavior of the coatings was evaluated by techniques open circuit potential monitoring (OCP), potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The results demonstrate that the siloxane-PMMA films improve the protective properties of the tinplate, with the films obtained by acetic acid addition exhibiting the greatest improvement
Electrochemical and spectroscopic characterization of screen-printed gold-based electrodes modified with self-assembled monolayers and Tc85 protein
This work investigates the formation of self-assembled monolayers (SAMs) of cystamine and cystamine-glutaraldehyde on a screen-printed electrode, and the immobilization of the Tc85 protein (from Trypanosoma cruzi) on these monolayers. The methods used included infrared techniques, cyclic voltammetry, and electrochemical impedance spectroscopy. The electrochemical studies were performed at pH 6.9 in 0.1 mol L(-1) phosphate buffer solution containing Fe(CN)(6)(-3/-4) redox species. The surface coverage (0) of the electrode was 0.10 (cystamine), 0.35 (cystamine-glutaraldehyde) and 0.84 (Tc85). Interpretation of electrochemical impedance spectroscopy results was based on a charge-transfer reaction involving Fe(CN)(6)(-3/-4) species at high frequencies, followed by a diffusion through the monolayers at lower frequencies. Estimates of the electrode surface coverage, active site radius, and distance between two adjacent sites assumed that charge transfer occurred at the active sites, and that there was a planar diffusion of redox species to these sites. (C) 2009 Elsevier B.V. All rights reserved.FAPESP[05/50574-4]CNPq[150670/2007-9]CNPq[300728/2007-7]FUNDUNESP[01093/05-DFP
Como polir uma montanha
Esta reflexão visa contextualizar o processo criativo da componente prática do Trabalho de Projecto – Objecto conferente do grau de Mestre em Teatro, especialização em Artes Performativas – Interpretação, e que consiste no solo Como polir uma montanha que teve lugar no Lavadouro Público de Carnide com Acolhimento do Teatro do Silêncio em Maio de 2014. O objectivo foi criar um espectáculo com base em acções de limpeza, utilizando os gestos quotidianos como elemento catalisador do processo criativo. Procurei, desta forma, espelhar algumas rotinas do dia-a-dia no campo abstracto das artes performativas, desconstruindo o espaço privado e servindo-me do corpo como ferramenta primordial na comunicação destas acções através do movimento. A premissa para este solo partiu da limpeza enquanto acção passível de gerar transformação no espaço e no tempo, e também no corpo e na mente. Inicialmente pensei que a limpeza era fundamental para a organização destes elementos, contudo o resultado levou-me a compreender que limpeza e organização podem ter pressupostos muito distintos.
Fundamentei a minha pesquisa observando acções quotidianas de limpeza em contextos diversificados como a vivência rural, a vivência urbana e ao nível da memória – a minha e a de outros indivíduos – de como processamos determinados comportamentos observados desde a infância. Durante o processo de criação de Como polir uma montanha, surgiram diversas inquietações que me levaram a reflectir também sobre a problemática de ser criadora e intérprete a solo, e de como esta questão é transversal à noção de si mesmo perante o outro. Esta noção leva-me a questionar o limiar que separa, mas também une, o palco e a plateia. Por isso integrei o público na acção cénica, através de elementos que propunham uma observação participativa do espectáculo.ABSTRACT - This refection as the porpose of contextualize the creative process of the practical componet of Project Work – Lecture subject of the Master degree of Theatre, specialization Performing Arts – Interpretation, and consists on the solo performance Como polir uma montanha that happened at the public laudry washer of Carnide ( Lavadouro público de Carnide) with reception by Teatro do Silêncio in May 2014. The goal was to create a performance based on cleaning actions, using quotidian gestures as a catalyst element for the creative process. Sought, this way, mirror some of the daily rotines in the abstrac field of performing arts, desconstructing the private space and using the body as a fundamental tool in comunicating this actions through out movement. The principle-based aproach to this solo, was cleaning as an action that may generate in space and time transformation but also in the body and mind. Initially I though that cleaning was essencial to organize this elements, but the result led me tounderstand that cleaning and organization may have many different assumptions.
I based my research observing quotidian cleaning actions in different environments such as rural experiences, urban experiences and at memory levels – mine and from others – of how we process certain behaviors observed since childhood. During the creation process of Como polir uma montanha, several concerns emerged that led me to also refect about the problematic of being a solo creator and interpreter, and how this question cross the notion of self before the other. This notion takes me to question the threshold that separates, but also unifies, stage and audience. For this reason, I joined the public in the scenic action, through elements that proposed a participative observation of the performance
Comparative study of Cr3C2-NiCr coatings obtained by HVOF and hard chromium coatings
In the present work the corrosion resistance of micro-cracked hard chromium and Cr3C2-NiCr (HVOF) coatings applied on a steel substrate have been compared using open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarization curves. The coatings surfaces and cross-section were characterized before and after corrosion tests using optical microscopy (OM) and scanning electron microscopy (SEM). After 18 h of immersion, the open-circuit potential values were around -0.50 and -0.25V/(Ag vertical bar AgCl vertical bar KClsat) for hard chromium and Cr3C2- NiCr, respectively. The surface analysis done after 12 h of immersion showed iron on the hard chromium surface inside/near surface cracks, while iron was not detected on the Cr3C2-NiCr surface even after 18 h. For longer immersion time hard chromium was more degraded than thermal sprayed coating. For hard chromium coating a total resistance values between 50 and 80 k Omega cm(2) were measured and two well-defined time constants were observed, without significant change with the immersion time. For Cr3C2-NiCr coating the total impedance diminished from around 750 to 25 k Omega cm(2) as the immersion time increased from 17 up to 132 h and two overlapped time constants were also observed. Polarization curves recorded after 18 h of immersion showed a lower current and higher corrosion potential for Cr3C2-NiCr coating than other samples studied. (c) 2005 Elsevier Ltd. All rights reserved
Funcionalidade e aptidão física funcional em idosos independentes residentes na comunidade no concelho de Loures
Objectivo do estudo - Caracterizar a aptidão física funcional e outros parâmetros da funcionalidade em idosos residentes na comunidade. Relevância do estudo - A população portuguesa apresenta um risco elevado de declínio funcional e fragilidade. Esta tendência, em conjunto um índice de envelhecimento crescente, coloca um grande desafio à sociedade, nomeadamente a nível económico, mas sobretudo no que se refere ao estado de saúde dos idosos, tendo a fisioterapia um papel importante na prevenção do declínio funcional e na manutenção da capacidade funcional destes indivíduos
Corrosion behavior of carbon steel protected with single and bi-layer of silane films filled with silica nanoparticles
The electrochemical behaviour of carbon steel coated with bis-[trimethoxysilylpropyl]amine (BTSPA) filled with silica nanoparticles in naturally aerated 0.1 mol L-1 NaCl solutions was evaluated. The coating was prepared by adding different concentrations of silica nanoparticles (100, 200, 300, 400 and 500 ppm) to the hydrolysis solution and then a second layer without silica nanoparticles was applied. The electrochemical behavior of the coated steel was evaluated by means of open-circuit potential (E-OC), electrochemical impedance spectroscopy (EIS) and polarization curves. Surface characterization was made by atomic force microscopy (AFM), and its hydrophobicity assessed by contact angle measurements. EIS diagrams have shown an improvement of the barrier properties of the silane layer with the silica addition, which was further improved on the bi-layer system. However, a dependence on the filler concentration was verified, and the best electrochemical response was obtained for samples modified with 300 ppm of silica nanoparticles. AFM images have shown a homogeneous distribution of the silica nanoparticles on the sample surface; however particles agglomeration was detected, which degraded the corrosion protection performance. The results were explained on the basis of the improvement of the barrier properties of the coating due to the filler addition and on the onset of defective regions on the more heavily filled coatings allowing easier electrolyte penetration. (C) 2007 Elsevier B.V. All rights reserved
Influence of spraying parameters on the electrochemical behaviour of HVOF thermally sprayed stainless steel coatings in 3.4% NaCl
Stainless steel coatings obtained by High Velocity Oxygen Fuel (HVOF) were characterized using optical (OM) and scanning electron microscopy (SEM), electron probe micro-analysis, X-ray diffraction (XRD), open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarisation tests. Differences among coated steels were mainly related with the gun-substrate distance parameter (310 nm for samples A and B and 260 min for C and D). The open-circuit potential values measured for all the samples after 18 h of immersion in aerated and unstirred 3.4% NaCl solution were: - 0.334, - 0.360, - 0.379 and - 0.412 V vs. Ag/AgCl,KClsat. for samples A to D, respectively. For EIS measurements, Nyquist plots showed higher capacitive semi-circle for samples sprayed at longer distance, indicating higher corrosion resistance in NaCl solution. (c) 2005 Elsevier B.V. All rights reserved
High-velocity oxyfuel Cr3C2-NiCr replacing hard chromium coatings
Comparative wear and corrosion properties of Cr3C2-NiCr (CC-TS) (a high-velocity oxyfuel [HVOF]) and hard chromium (HC) coating's obtained on a steel substrate have been studied. The structural characterization was done before and after measurements by optical microscopy, scanning electron microscopy, and scanning white light interferometry. Wear and corrosion properties were evaluated by ball on disk (ASTM G99-90), rubber wheel (ASTM G65-91), and electrochemical measurements of open circuit and polarization curves. The best corrosion and wear resistance was for the CC-TS obtained by HVOF. The open-circuit potential values measured for both samples after 18 h of immersion we're: -0.240 and -0.550 V, respectively, for CC-TS and HC, versus Ag/AgCl,KClsat. Three orders of magnitude lower volume loss were found for CC-TS (HVOF) after friction tests compared with HC