122 research outputs found

    Morphometric versus densitometric assessment of coronary vasomotor tone-an overview

    Get PDF
    The main advantage of the morphometric approach is that the spatial orientation of the vessel with respect to the image intensifier is not very important. Its most severe limitations are that reasonable accuracy can only be obtained with circular lumina, and that accuracy decreases rapidly with the vessel diameter. The densitometric approach is much less dependent on the shape of the lumen and on the correct identification of the vessel wall in the image. A further essential advantage is that one measures directly the cross-sectional area of the vessel instead of a ‘diameter' of low haemodynamic relevance. Severe requirements must however be met if the potential accuracy of densitometry is to be fully exploited. The morphometric approach seems thus preferable for absolute or relative diameter measurements on intact vessels, while densitometry is superior in case of irregular or small lumina. Morphometric calibration using the injection catheter can induce non-negligible errors in both approaches. Grid calibration is probably more accurate, but also more tedious. In the densitometric approach, ‘3D-calibration' by help of a cube of known size allows also determination of the spatial orientation of the vessel in space. This solution requires however biplane imagin

    Cavitation Bubble Dynamics inside Liquid Drops in Microgravity

    Get PDF
    We studied spark-generated cavitation bubbles inside water drops produced in microgravity. High-speed visualizations disclosed unique effects of the spherical and nearly isolated liquid volume. In particular, (1) toroidally collapsing bubbles generate two liquid jets escaping from the drop, and the "splash jet" discloses a remarkable broadening. (2) Shockwaves induce a strong form of secondary cavitation due to the particular shockwave confinement. This feature offers a novel way to estimate integral shockwave energies in isolated volumes. (3) Bubble lifetimes in drops are shorter than in extended volumes in remarkable agreement with herein derived corrective terms for the Rayleigh-Plesset equation

    New insight into cataract formation -- enhanced stability through mutual attraction

    Get PDF
    Small-angle neutron scattering experiments and molecular dynamics simulations combined with an application of concepts from soft matter physics to complex protein mixtures provide new insight into the stability of eye lens protein mixtures. Exploring this colloid-protein analogy we demonstrate that weak attractions between unlike proteins help to maintain lens transparency in an extremely sensitive and non-monotonic manner. These results not only represent an important step towards a better understanding of protein condensation diseases such as cataract formation, but provide general guidelines for tuning the stability of colloid mixtures, a topic relevant for soft matter physics and industrial applications.Comment: 4 pages, 4 figures. Accepted for publication on Phys. Rev. Let

    A Universal Scaling Law for Jets of Collapsing Bubbles

    Full text link
    Cavitation bubbles collapsing and rebounding in a pressure gradient grad(p) form a "micro-jet" enveloped by a "vapor jet". This letter presents unprecedented observations of the vapor jets formed in a uniform gravity-induced grad(p), modulated aboard parabolic flights. The data uncovers that the normalized jet volume is independent of the liquid density and viscosity and proportional to zeta=grad(p)*R0/p, where R0 is the maximal bubble radius and p is the driving pressure. A derivation inspired by "Kelvin-Blake" considerations confirms this law and reveals its negligible dependence of surface tension. We further conjecture that the jet only pierces the bubble boundary if zeta>0.0004.Comment: 4 page letter, 4 figure

    Could increased axial wall stress be responsible for the development of atheroma in the proximal segment of myocardial bridges?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A recent model describing the mechanical interaction between a stenosis and the vessel wall has shown that axial wall stress can considerably increase in the region immediately proximal to the stenosis during the (forward) flow phases, so that abnormal biological processes and wall damages are likely to be induced in that region. Our objective was to examine what this model predicts when applied to myocardial bridges.</p> <p>Method</p> <p>The model was adapted to the hemodynamic particularities of myocardial bridges and used to estimate by means of a numerical example the cyclic increase in axial wall stress in the vessel segment proximal to the bridge. The consistence of the results with reported observations on the presence of atheroma in the proximal, tunneled, and distal vessel segments of bridged coronary arteries was also examined.</p> <p>Results</p> <p>1) Axial wall stress can markedly increase in the entrance region of the bridge during the cardiac cycle. 2) This is consistent with reported observations showing that this region is particularly prone to atherosclerosis.</p> <p>Conclusion</p> <p>The proposed mechanical explanation of atherosclerosis in bridged coronary arteries indicates that angioplasty and other similar interventions will not stop the development of atherosclerosis at the bridge entrance and in the proximal epicardial segment if the decrease of the lumen of the tunneled segment during systole is not considerably reduced.</p

    Microcavity-integrated graphene photodetector

    Get PDF
    The monolithic integration of novel nanomaterials with mature and established technologies has considerably widened the scope and potential of nanophotonics. For example, the integration of single semiconductor quantum dots into photonic crystals has enabled highly efficient single-photon sources. Recently, there has also been an increasing interest in using graphene - a single atomic layer of carbon - for optoelectronic devices. However, being an inherently weak optical absorber (only 2.3 % absorption), graphene has to be incorporated into a high-performance optical resonator or waveguide to increase the absorption and take full advantage of its unique optical properties. Here, we demonstrate that by monolithically integrating graphene with a Fabry-Perot microcavity, the optical absorption is 26-fold enhanced, reaching values >60 %. We present a graphene-based microcavity photodetector with record responsivity of 21 mA/W. Our approach can be applied to a variety of other graphene devices, such as electro-absorption modulators, variable optical attenuators, or light emitters, and provides a new route to graphene photonics with the potential for applications in communications, security, sensing and spectroscopy.Comment: 19 pages, 4 figure

    Patterns of paediatric end-of-life care: a chart review across different care settings in Switzerland.

    Get PDF
    Paediatric end-of-life care is challenging and requires a high level of professional expertise. It is important that healthcare teams have a thorough understanding of paediatric subspecialties and related knowledge of disease-specific aspects of paediatric end-of-life care. The aim of this study was to comprehensively describe, explore and compare current practices in paediatric end-of-life care in four distinct diagnostic groups across healthcare settings including all relevant levels of healthcare providers in Switzerland. In this nationwide retrospective chart review study, data from paediatric patients who died in the years 2011 or 2012 due to a cardiac, neurological or oncological condition, or during the neonatal period were collected in 13 hospitals, two long-term institutions and 10 community-based healthcare service providers throughout Switzerland. Ninety-three (62%) of the 149 reviewed patients died in intensive care units, 78 (84%) of them following withdrawal of life-sustaining treatment. Reliance on invasive medical interventions was prevalent, and the use of medication was high, with a median count of 12 different drugs during the last week of life. Patients experienced an average number of 6.42 symptoms. The prevalence of various types of symptoms differed significantly among the four diagnostic groups. Overall, our study patients stayed in the hospital for a median of six days during their last four weeks of life. Seventy-two patients (48%) stayed at home for at least one day and only half of those received community-based healthcare. The study provides a wide-ranging overview of current end-of-life care practices in a real-life setting of different healthcare providers. The inclusion of patients with all major diagnoses leading to disease- and prematurity-related childhood deaths, as well as comparisons across the diagnostic groups, provides additional insight and understanding for healthcare professionals. The provision of specialised palliative and end-of-life care services in Switzerland, including the capacity of community healthcare services, need to be expanded to meet the specific needs of seriously ill children and their families
    corecore