1,624 research outputs found

    A system for online beam emittance measurements and proton beam characterization

    Full text link
    A system for online measurement of the transverse beam emittance was developed. It is named 4^{4}PrOBε\varepsilonaM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way using the multiple beam profiler method. The core of the system is constituted by four consecutive UniBEaM profilers, which are based on silica fibers passing across the beam. The 4^{4}PrOBε\varepsilonaM system was deployed for characterization studies of the 18~MeV proton beam produced by the IBA Cyclone 18 MeV cyclotron at Bern University Hospital (Inselspital). The machine serves daily radioisotope production and multi-disciplinary research, which is carried out with a specifically conceived Beam Transport Line (BTL). The transverse RMS beam emittance of the cyclotron was measured as a function of several machine parameters, such as the magnetic field, RF peak voltage, and azimuthal angle of the stripper. The beam emittance was also measured using the method based on the quadrupole strength variation. The results obtained with both techniques were compared and a good agreement was found. In order to characterize the longitudinal dynamics, the proton energy distribution was measured. For this purpose, a method was developed based on aluminum absorbers of different thicknesses, a UniBEaM detector, and a Faraday cup. The results were an input for a simulation of the BTL developed in the MAD-X software. This tool allows machine parameters to be tuned online and the beam characteristics to be optimized for specific applications.Comment: published in Journal of Instrumentatio

    An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles

    Get PDF
    A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.Comment: published in JINST (4th Feb 2013

    Significant enhancement of irreversibility field in clean-limit bulk MgB2

    Full text link
    Low resistivity ("clean") MgB2 bulk samples annealed in Mg vapor show an increase in upper critical field Hc2(T) and irreversibility field Hirr(T) by a factor of 2 in both transport and magnetic measurements. The best sample displayed Hirr above 14 T at 4.2 K and 6 T at 20 K. These changes were accompanied by an increase of the 40 K resistivity from 1.0 to 18 microohm-cm and a lowering of the resistivity ratio from 15 to 3, while the critical temperature Tc decreased by only 1-2 K. These results point the way to make prepare MgB2 attractive for magnet applications.Comment: 3 pages, 4 figures, submitted to Applied Physics Letter

    Angular dependence of magnetoresistivity in c-oriented MgB2 thin film

    Full text link
    The anisotropy of MgB2 is still under debate: its value, strongly dependent on the sample and on the measuring method, ranges between 1.2 and 13. In this work we present our results on a MgB2 c-oriented superconducting thin film. To evaluate the anisotropy, we followed two different approaches. Firstly, magnetoresistivity was measured as a function of temperature at selected magnetic fields applied both parallel and perpendicular to the c-axis; secondly, we measured magnetoresistivity at selected temperatures and magnetic fields, varying the angle q between the magnetic field and the c-axis. The anisotropy estimated from the ratio between the upper critical fields parallel and perpendicular to the c-axis and the one obtained in the framework of the scaling approach within the anisotropic Ginzburg-Landau theory are different but show a similar trend in the temperature dependence. The obtained results are compared and discussed in the light of the two-band nature of MgB2. A comparison between critical fields in thin films and single crystal is also performed.Comment: 13 pages, 4 figures, European Physical Journal B in pres

    Critical Field of MGB2 : Crossover from Clean to Dirty Regimes

    Full text link
    We have studied the upper critical field, Bc2, in poly-crystalline MgB2 samples in which disorder was varied in a controlled way to carry selectively p and s bands from clean to dirty limit. We have found that the clean regime survives when p bands are dirty and s bands are midway between clean and dirty. In this framework we can explain the anomalous behaviour of Al doped samples, in which Bc2 decreases as doping increases.Comment: 11 pages, 2 figure

    Ostracodes; witnesses of the Plio-Quaternary boundary in the North Eastern Atlantic preliminary results

    Get PDF
    Proceedings of the 1" R.C.A.N.S. Congress, Lisboa, October 1992The 2,4 MY crisis is an important event for the upper Neogene ofNorth Atlantic. A new climatic system occur and widespread during the Quaternary and is characterized by glacial and interglacial alternance. To follow the different steps of this crisis, we have choosen a borehole situated in the Cotentin peninsula (Normandy, France) and used ostracodes such as markers. The interpretation of quantitative and qualitative data from the ostracode fauna analysis shows that bathymetry was around 40 and 60 meters with slight fluctuations, excepted during Praetiglian event where the zone was outofwater. The morphologicalvariability analysis offour species (the best represented in the core), show a low variability between the basement and 80 meters. Beyond this limit and after 10 meters, characterized by very low values, the variability increases to very high values to the top of the core. Present data; Abe et Choe, 1988; Peypouquet et al, 1988; Carbonel et al., 1990 a, 1990 b; show that there is a close link between seasonal contrast intensity and ostracode intraspecifical morphological variations. The carbonates balance at the interface water / sediment, were ostracodes live and moult, is related and reflects the intensity of the seasonal contrast. After the Praetiglian event, an increase of the seasonal contrast occurs during the Tiglian A and the lower Tiglian B

    Study of the radioactivity induced in air by a 15-MeV proton beam

    Get PDF
    Radioactivity induced by a 15-MeV proton beam extracted into air was studied at the beam transport line of the 18-MeV cyclotron at the Bern University Hospital (Inselspital). The produced radioactivity was calculated and measured by means of proportional counters located at the main exhaust of the laboratory. These devices were designed for precise assessment of air contamination for radiation protection purposes. The main produced isotopes were 11C, 13N and 14O. Both measurements and calculations correspond to two different irradiation conditions. In the former, protons were allowed to travel for their full range in air. In the latter, they were stopped at the distance of 1.5 m by a beam dump. Radioactivity was measured continuously in the exhausted air starting from 2 min after the end of irradiation. For this reason, the short-lived 14O isotope gave a negligible contribution to the measured activity. Good agreement was found between the measurements and the calculations within the estimated uncertainties. Currents in the range of 120-370 nA were extracted in air for 10-30 s producing activities of 9-22 MBq of 11C and 13N. The total activities for 11C and 13N per beam current and irradiation time for the former and the latter irradiation conditions were measured to be (3.60 ± 0.48) × 10−3 MBq (nA s)−1 and (2.89 ± 0.37) × 10−3 MBq (nA s)−1, respectivel

    A beam monitor detector based on doped silica and optical fibres

    Full text link
    A beam monitor detector prototype based on doped silica fibres coupled to optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam has been measured, giving information on beam position, shape and intensity. Mostly based on commercial components, the detector is easy to install, to operate and no electronic components are located near the beam. Tests have been performed with a 2 MeV proton pulsed beam at an average current of 0.8 {\mu}A. The response characteristics of Sb doped silica fibres have been studied for the first time
    • …
    corecore