35 research outputs found

    Interaction of TIS and ST in environmental matters

    Get PDF
    The role of TIS concerning environmental matters in view of the SAPOCO 42 document will be tackled. Interactions between TIS and ST, as the Division managing water networks, ventilation systems and various potentially polluting installations, will be discussed both for the planning as well as for the operational phase. A systematic approach to the problem within the foreseen CERN-wide Environmental Management System will be described

    Monte Carlo simulation of muon-induced background of an anti-Compton gamma-ray spectrometer placed in a surface and underground laboratory

    Get PDF
    Simulations of cosmic ray muon induced background of an HPGe detector placed inside an anti-Compton shield on the surface and in shallow underground is described. Investigation of several model set-ups revealed some trends useful for design of low-level gamma-ray spectrometers. It has been found that background spectrum of an HPGe detector can be scaled down with the shielding depth. No important difference is observed when the same set-up of the anti-Compton spectrometer is positioned horizontally or vertically. A cosmic-muon rejection factor of at least 40 (at around 1 MeV) can be reached when the anti-Compton suppression is operational. The cosmicmuon background can be reduced to such a level that other background components prevail, like those from the residual contamination of the detector and shield materials and/or from radon, especially for the underground facilities

    Rejets radioactifs et environnement du CERN en 2004

    Get PDF
    La radioactivité de l’environnement autour de l’Organisation Européenne pour la Recherche Nucléaire (CERN) et les doses de rayonnements qui en résultent pour la population avoisinante sont contrôlées par la Commission de Sécurité du CERN et de manière indépendante par les autorités compétentes des deux États Hôtes, l’Institut de Radioprotection et de Sûreté Nucléaire (IRSN) côté France et l’Office Fédéral de la Santé Publique (OFSP) côté Suisse. Dans ce rapport, les résultats de mesures concernent en particulier le territoire suisse. L’ensemble des mesures effectuées en 2004 prouve que le fonctionnement des installations du CERN était sans conséquence radiologique sur l’environnement et la population. Le contrôle des émissions montre que les rejets effectifs se situent également en 2004 nettement en dessous des limites réglementaires. Ce constat est confirmé par le contrôle des immissions dans l’environnement. Le CERN a bien respecté en 2004 comme dans les années précédentes la valeur directrice de dose liée à la source fixée à 0.3 mSv/an. L’impact réel représente en fait moins de 5% de cette valeur, comme l’indique l’estimation pour le groupe de référence, qui est de l’ordre de 0.01 mSv/an

    Rejets et environnement du CERN

    Get PDF
    La radioactivité de l’environnement autour de l’Organisation Européenne pour la Recherche Nucléaire (CERN) et les doses de rayonnements qui en résultent pour la population avoisinante sont contrôlées par la Commission de Sécurité du CERN et de manière indépendante par les autorités compétentes des deux États Hôtes, l’Institut de Radioprotection et de Sûreté Nucléaire (IRSN) côté France et l’Office Fédéral de la Santé Publique (OFSP) côté Suisse (voire Chapitre 8.6). Dans ce rapport, les résultats de mesures concernent en particulier le territoire suisse. L’ensemble des mesures effectuées en 2006 prouve que le fonctionnement des installations du CERN était sans conséquence radiologique sur l’environnement et la population. Le contrôle des émissions montre que les rejets effectifs se situent, également en 2006, nettement en dessous des limites réglementaires. Ce constat est confirmé par le contrôle des immissions dans l’environnement. Le CERN a bien respecté en 2006 comme dans les années précédentes la valeur directrice de dose liée à la source fixée à 0.3 mSv/an. L’impact réel représente en fait seulement 2.5% de cette valeur, comme l’indique l’estimation pour le groupe de référence, qui est de l’ordre de 0.01 mSv/an

    Models for environmental impact assessments of releases of radioactive substances from CERN facilities

    Get PDF
    The document describes generic models for environmental impact assessments of releases of radioactive substances from CERN facilities. Except for few models developed in the Safety Commission, the models are based on the 1997 Swiss directive HSK-R-41 and on the 2001 IAEA Safety Report No. 19. The writing style is descriptive, facilitating the practical implementation of the models at CERN. There are four scenarios assumed for airborne releases: (1) short-term releases for release limit calculations, (2) actual short-term releases, (3) short-term releases during incidents/accidents, and (4) chronic long-term releases during the normal operation of a facility. For water releases, two scenarios are considered: (1) a release into a river, and (2) a release into a water treatment plant. The document shall be understood as a reference for specific environmental studies involving radioactive releases and as a recommendation of the Safety Commission

    Integrated Safety and Environment Group: Annual Report 2003

    Get PDF
    This report summarizes the main activities of the Integrated Safety and Environment (IE) Group of the Safety Commission (TIS) during the year 2003, and the results obtained. The different topics in which the group is active are covered: environment, quality management, safety training and major accidents follow-up

    Rejets radioactifs et environnement du CERN en 2003

    Get PDF
    La radioactivité de l’environnement autour de l’Organisation Européenne pour la Recherche Nucléaire (CERN) et les doses de rayonnements qui en résultent pour la population avoisinante sont contrôlées par la Commission de Sûreté du CERN et de manière indépendante par les autorités compétentes des deux Etats Hôtes, l’Institut de Radioprotection et de Sûreté Nucléaire (IRSN) côté France et l’Office Fédéral de la Santé Publique (OFSP) côté Suisse. Dans ce rapport, les résultats de mesures concernent en particulier le territoire suisse. L’ensemble des mesures effectuées en 2003 prouve que le fonctionnement des installations du CERN était sans conséquence radiologique sur l’environnement et la population. Le contrôle des émissions montre que les rejets effectifs se situent également en 2003 nettement en dessous des limites réglementaires. Ce constat est confirmé par le contrôle des immissions dans l’environnement. Le CERN a bien respecté en 2003 comme dans les années précédentes la valeur directrice de dose liée à la source fixée à 0.3 mSv/an. L’impact réel représente en fait moins de 10% de cette valeur, comme l’indique l’estimation pour le groupe critique, qui est de l’ordre de 0.03 mSv/an

    An actively vetoed Clover gamma-detector for nuclear astrophysics at LUNA

    Full text link
    An escape-suppressed, composite high-purity germanium detector of the Clover type has been installed at the Laboratory for Underground Nuclear Astrophysics (LUNA) facility, deep underground in the Gran Sasso Laboratory, Italy. The laboratory gamma-ray background of the Clover detector has been studied underground at LUNA and, for comparison, also in an overground laboratory. Spectra have been recorded both for the single segments and for the virtual detector formed by online addition of all four segments. The effect of the escape-suppression shield has been studied as well. Despite their generally higher intrinsic background, escape-suppressed detectors are found to be well suited for underground nuclear astrophysics studies. As an example for the advantage of using a composite detector deep underground, the weak ground state branching of the Ep = 223 keV resonance in the 24Mg(p,gamma)25Al reaction is determined with improved precision.Comment: 8 pages, 6 figures, 3 tables; as accepted by Eur. Phys. J.
    corecore