172 research outputs found

    COVID-19 coronavirus: recommended personal protective equipment for the orthopaedic and trauma surgeon

    Get PDF
    PURPOSE: With the COVID-19 crisis, recommendations for personal protective equipment (PPE) are necessary for protection in orthopaedics and traumatology. The primary purpose of this study is to review and present current evidence and recommendations for personal protective equipment and safety recommendations for orthopaedic surgeons and trauma surgeons. METHODS: A systematic review of the available literature was performed using the keyword terms “COVID-19”, “Coronavirus”, “surgeon”, “health-care workers”, “protection”, “masks”, “gloves”, “gowns”, “helmets”, and “aerosol” in several combinations. The following databases were assessed: Pubmed, Cochrane Reviews, Google Scholar. Due to the paucity of available data, it was decided to present it in a narrative manner. In addition, participating doctors were asked to provide their guidelines for PPE in their countries (Austria, Luxembourg, Switzerland, Germany, UK) for consideration in the presented practice recommendations. RESULTS: World Health Organization guidance for respiratory aerosol-generating procedures (AGPs) such as intubation in a COVID19 environment was clear and included the use of an FFP3 (filtering face piece level 3) mask and face protection. However, the recommendation for surgical AGPs, such as the use of high-speed power tools in the operating theatre, was not clear until the UK Public Health England (PHE) guidance of 27 March 2020. This guidance included FFP3 masks and face protection, which UK surgeons quickly adopted. The recommended PPE for orthopaedic surgeons, working in a COVID19 environment, should consist of level 4 surgical gowns, face shields or goggles, double gloves, FFP2-3 or N95-99 respirator masks. An alternative to the mask, face shield and goggles is a powered air-purifying respirator, particularly if the surgeons fail the mask fit test or are required to undertake a long procedure. However, there is a high cost and limited availabilty of these devices at present. Currently available surgical helmets and toga systems may not be the solution due to a permeable top for air intake. During the current COVID-19 crisis, it appeared that telemedicine can be considered as an electronic personal protective equipment by reducing the number of physical contacts and risk contamination. CONCLUSION: Orthopaedic and trauma surgery using power tools, pulsatile lavage and electrocautery are surgical aerosol-generating procedures and all body fluids contain virus particles. Raising awareness of these issues will help avoid occupational transmission of COVID-19 to the surgical team by aerosolization of blood or other body fluids and hence adequate PPE should be available and used during orthopaedic surgery. In addition, efforts have to be made to improve the current evidence in this regard

    Infraglenoidal scapular notching in reverse total shoulder replacement: a prospective series of 60 cases and systematic review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The impact of infraglenoidal scapular notching in reversed total shoulder arthroplasty (RTSA) is still controversially discussed. Our goal was to evaluate its potential influence on subjective shoulder stability and clinical outcome. We hypothesized that subjective instability and clinical outcome after implantation of RTSA correlates with objective scapular notching.</p> <p>Methods</p> <p>Sixty shoulders were assessed preoperatively and at minimum 2-year follow-up for active range of motion and by use of the Oxford instability score, Rowe score for instability, Constant score for pain, Constant shoulder score, DASH score. All shoulders were evaluated on anterior-posterior and axillary lateral radiographic views. These X-ray scans were classified twice by two orthopaedic surgeons with respect to infraglenoidal scapular notching according to the classification of Nerot. Notching was tested for correlation with clinical outcome scores to the evaluated notching.</p> <p>Results</p> <p>We found no significant correlation between infraglenoidal scapular notching and clinical outcomes after a mid-term follow-up from 24 to 60 months, but at the final follow-up of 60 months and more, we did see statistically significant, positive correlations between infraglenoidal scapular notching and the Constant pain score as well as active range of motion. At mean follow-up of 42 months (range from 24 to 96 months) we found no significant correlation between subjective instability and infraglenoidal scapular notching.</p> <p>Conclusions</p> <p>We conclude that patients' subjective impression on their shoulders' stability is not correlating with radiological signs of infraglenoidal scapular notching. Nevertheless clinical parameters are affected by infraglenoidal scapular notching, at least in the long term</p

    Effects of mesenchymal stromal cells versus serum on tendon healing in a controlled experimental trial in an equine model

    Get PDF
    Abstract Background Mesenchymal stromal cells (MSC) have shown promising results in the treatment of tendinopathy in equine medicine, making this therapeutic approach seem favorable for translation to human medicine. Having demonstrated that MSC engraft within the tendon lesions after local injection in an equine model, we hypothesized that they would improve tendon healing superior to serum injection alone. Methods Quadrilateral tendon lesions were induced in six horses by mechanical tissue disruption combined with collagenase application 3 weeks before treatment. Adipose-derived MSC suspended in serum or serum alone were then injected intralesionally. Clinical examinations, ultrasound and magnetic resonance imaging were performed over 24 weeks. Tendon biopsies for histological assessment were taken from the hindlimbs 3 weeks after treatment. Horses were sacrificed after 24 weeks and forelimb tendons were subjected to macroscopic and histological examination as well as analysis of musculoskeletal marker expression. Results Tendons injected with MSC showed a transient increase in inflammation and lesion size, as indicated by clinical and imaging parameters between week 3 and 6 (p < 0.05). Thereafter, symptoms decreased in both groups and, except that in MSC-treated tendons, mean lesion signal intensity as seen in T2w magnetic resonance imaging and cellularity as seen in the histology (p < 0.05) were lower, no major differences could be found at week 24. Conclusions These data suggest that MSC have influenced the inflammatory reaction in a way not described in tendinopathy studies before. However, at the endpoint of the current study, 24 weeks after treatment, no distinct improvement was observed in MSC-treated tendons compared to the serum-injected controls. Future studies are necessary to elucidate whether and under which conditions MSC are beneficial for tendon healing before translation into human medicine

    Auto-aggressive metallic mercury injection around the knee joint: a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Accidental or intentional subcutaneous and/or intramuscular injection of metallic mercury is an uncommon form of poisoning. Although it does not carry the same risk as mercury vapour inhalation, it may cause destructive early and late reactions.</p> <p>Case Presentation</p> <p>Herein we present the case of a 29-year-old male patient who developed an obsessive-compulsive disorder causing auto-aggressive behaviour with injection of elemental mercury and several other foreign bodies into the soft tissues around the left knee about 15 years before initial presentation. For clinical examination X-rays and a CT-scan of the affected area were performed. Furthermore, blood was taken to determine the mercury concentration in the blood, which showed a concentration 17-fold higher than recommended. As a consequence, the mercury depots and several foreign bodies were resected marginally.</p> <p>Conclusion</p> <p>Blood levels of mercury will decrease rapidly following surgery, especially in combination with chelating therapy. In case of subcutaneous and intramuscular injection of metallic mercury we recommend marginal or wide excision of all contaminated tissue to prevent migration of mercury and chronic inflammation. Nevertheless, prolonged clinical and biochemical monitoring should be performed for several years to screen for chronic intoxication.</p

    Ceramic on ceramic bearing fractures in total hip arthroplasty : an analysis of data from the national joint registry

    Get PDF
    Aims: Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR). Patients and Methods: We analysed data on 111,681 primary CoC THA’s and 182 linked revisions for bearing fracture recorded in NJR. We used implant codes to identify ceramic bearing composition and generated Kaplan-Meier estimates for implant survivorship. Logistic regression analyses were performed for implant size and patient specific variables to determine any associated risks for revision. Results: 99.8% of bearings were CeramTec Biolox® products. Revisions for fracture were linked to 7 of 79,442 (0.009%) Biolox® Delta heads, 38 of 31,982 (0.119%) Biolox® Forte heads, 101 of 80,170 (0.126%) Biolox® Delta liners and 35 of 31,258 (0.112%) Biolox® Forte liners. Regression analysis of implant size revealed smaller heads had significantly higher odds of fracture (χ2=68.0, p<0.0001). The highest fracture risk were observed in the 28mm Biolox® Forte subgroup (0.382%). There were no fractures in the 40mm head group for either ceramic type. Liner thickness was not predictive of fracture (p=0.67). BMI was independently associated with revision for both head fractures (OR 1.09 per unit increase, p=0.031) and liner fractures (OR 1.06 per unit increase, p=0.006). Conclusions: We report the largest study of CoC bearing fractures to date. The risk of revision for CoC bearing fracture is very low, however previous studies have underestimated this risk. There is good evidence that the latest generation of ceramic has greatly reduced the odds of head fracture but not of liner fracture. Small head size and high patient BMI are associated with an increased risk of ceramic bearing fracture

    Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Low-contact-stress (LCS) mobile-bearing total knee arthroplasty (TKA) (Johnson & Johnson, New Brunswick, NJ; previously: DePuy, Warsawa, USA) provides excellent functional results and wear rates in long-term follow-up analyses. Radiological analysis shows radiolucent lines (RLL) appearing immediately or two years after primary implantation, indicative of poor seat. Investigations proved RLL to be more frequent in uncemented TKA, resulting in a consensus to cement the tibial plateau, but their association with clinical findings and patients discomfort and knee pain is still unknown.</p> <p>Methods</p> <p>553 patients with 566 low-contact-stress (LCS) total knee prostheses were screened for continuous moderate knee pain. We compared tibial stress shielding classified by Ewald in patients suffering from pain with a matched, pain-free control group on blinded X-rays. We hypothesized a positive correlation between pain and radiolucency and higher frequency of such radiolucent lines in the most medial and most lateral zones of the tibial plateau.</p> <p>Results</p> <p>Twenty-eight patients suffered from knee pain in total. Radiolucencies were detected in 27 of these cases and in six out of 28 matched controls without knee pain. We could demonstrate a significant correlation of knee pain and radiolucencies, which appeared significantly more frequently in the outermost zones of the tibial plateau.</p> <p>Conclusion</p> <p>Our findings suggest that radiolucent lines, representing poor implant seat, about the tibial plateau are associated with knee pain in LCS patients. Radiolucencies are observed more often in noncemented LCS, and cementing the tibial plateau might improve implant seat and reduce both radiolucent lines and associated knee pain.</p
    • …
    corecore