598 research outputs found

    Proton-counting radiography for proton therapy: a proof of principle using CMOS APS technology

    Get PDF
    Despite the early recognition of the potential of proton imaging to assist proton therapy (Cormack 1963 J. Appl. Phys. 34 2722), the modality is still removed from clinical practice, with various approaches in development. For proton-counting radiography applications such as computed tomography (CT), the water-equivalent-path-length that each proton has travelled through an imaged object must be inferred. Typically, scintillator-based technology has been used in various energy/range telescope designs. Here we propose a very different alternative of using radiation-hard CMOS active pixel sensor technology. The ability of such a sensor to resolve the passage of individual protons in a therapy beam has not been previously shown. Here, such capability is demonstrated using a 36 MeV cyclotron beam (University of Birmingham Cyclotron, Birmingham, UK) and a 200 MeV clinical radiotherapy beam (iThemba LABS, Cape Town, SA). The feasibility of tracking individual protons through multiple CMOS layers is also demonstrated using a two-layer stack of sensors. The chief advantages of this solution are the spatial discrimination of events intrinsic to pixelated sensors, combined with the potential provision of information on both the range and residual energy of a proton. The challenges in developing a practical system are discussed

    OPTIma:a tracking solution for proton computed tomography in high proton flux environments

    Get PDF
    Currently there is a large discrepancy between the currents that are used for treatments in proton beam therapy facilities and the ultra low beam currents required for many proton CT imaging systems. Here we provide details of the OPTIma silicon strip based tracking system, which has been designed for performing proton CT imaging in conditions closer to the high proton flux environments of modern spot scanning treatment facilities. Details on the physical design, sensor testing, modelling, and track reconstruction are provided along with Monte-Carlo simulation studies of the expected performance for proton beam currents of up to 50 pA at the nozzle when using a σ = ∼10 mm spot scanning cyclotron system. Using a detailed simulation of the proposed OPTIma system, a discrepancy of less than 1% on the Relative Stopping Power is found for various tissues when embedded within a 150 mm diameter Perspex sphere. It is found that by accepting up to 7 protons per bunch it is possible to operate at cyclotron beam currents up to 5 times higher than would be possible with a single proton based readout, significantly reducing the total beam time required to produce an image, while also reducing the discrepancy between the beam currents required for treatment and those used for proton CT

    A rare case of paediatric astroblastoma with concomitant MN1-GTSE1 and EWSR1-PATZ1 gene fusions altering management

    Get PDF
    In a case of astroblastoma, methylation analysis was uninformative, with no clustering with known CNS-HGNET-MN1 cases. Whole genome sequencing however identified a novel MN1-GTSE1 gene fusion (image), confirming the diagnosis of astroblastoma, as well as an EWSR1-PATZ1 gene fusion. Whole genome sequencing, alongside methylation profiling and conventional neuropathology, will continue to lead to improved diagnostics and prognostication for children with brain tumours

    Proton tracking for medical imaging and dosimetry

    Get PDF
    For many years, silicon micro-strip detectors have been successfully used as tracking detectors for particle and nuclear physics experiments. A new application of this technology is to the field of particle therapy, where radiotherapy is carried out by use of charged particles such as protons or carbon ions. Such a treatment has been shown to have advantages over standard x-ray radiotherapy and as a result of this, many new centres offering particle therapy are currently under construction—including two in the U.K.. The characteristics of a new silicon micro-strip detector based system for this application will be presented. The array uses specifically designed large area sensors in several stations in an x-u-v co-ordinate configuration suitable for very fast proton tracking with minimal ambiguities. The sensors will form a tracker capable of giving information on the path of high energy protons entering and exiting a patient. This will allow proton computed tomography (pCT) to aid the accurate delivery of treatment dose with tuned beam profile and energy. The tracker will also be capable of proton counting and position measurement at the higher fluences and full range of energies used during treatment allowing monitoring of the beam profile and total dose. Results and initial characterisation of sensors will be presented along with details of the proposed readout electronics. Radiation tests and studies with different electronics at the Clatterbridge Cancer Centre and the higher energy proton therapy facility of iThemba LABS in South Africa will also be shown

    Expected proton signal sizes in the PRaVDA Range Telescope for proton Computed Tomography

    Get PDF
    Proton radiotherapy has demonstrated benefits in the treatment of certain cancers. Accurate measurements of the proton stopping powers in body tissues are required in order to fully optimise the delivery of such treaments. The PRaVDA Consortium is developing a novel, fully solid state device to measure these stopping powers. The PRaVDA Range Telescope (RT), uses a stack of 24 CMOS Active Pixel Sensors (APS) to measure the residual proton energy after the patient. We present here the ability of the CMOS sensors to detect changes in the signal sizes as the proton traverses the RT, compare the results with theory, and discuss the implications of these results on the reconstruction of proton tracks

    Learning HCI Across Institutions, Disciplines and Countries: A Field Study of Cognitive Styles in Analytical and Creative Tasks

    Get PDF
    Human-computer interaction (HCI) is increasingly becoming a subject taught in universities around the world. However, little is known of the interactions of the HCI curriculum with students in different types of institutions and disciplines internationally. In order to explore these interactions, we studied the performance of HCI students in design, technology and business faculties in universities in UK, India, Namibia, Mexico and China who participated in a common set of design and evaluation tasks. We obtained participants’ cognitive style profiles based on Allinson and Hayes scale in order to gain further insights into their learning styles and explore any relation between these and performance. We found participants’ cognitive style preferences to be predominantly in the adaptive range, i.e. with combined analytical and intuitive traits, compared to normative data for software engineering, psychology and design professionals. We further identified significant relations between students’ cognitive styles and performance in analytical and creative tasks of a HCI professional individual. We discuss the findings in the context of the distinct backgrounds of the students and universities that participated in this study and the value of research that explores and promotes diversity in HCI education
    • …
    corecore