7 research outputs found
EGFR or PD-L1 decision for first line therapy in a case series of EGFR positive and PD-L1 >50%
Targeted therapies are on the market for the past five years and recently pembrolizumab was approved as first line treatment for patients with PD-L1 >50%. We present three cases of patients which had epidermal growth factor receptor positive expression and programmed death-ligand 1 (PD-L1), PD-L1 >50% overexpression. © 201
Three‐Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
The Influence of Impression Material on the Accuracy of the Master Cast in Implant Restorations
A patient who made an impact on how I practice: Severe leptospirosis presenting as ARDS in the ICU
Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques
The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis
Aim: This systematic review and meta-analysis were conducted to assess and compare the accuracy of conventional and digital implant impressions. The review was registered on the PROSPERO register (registration number: CRD42016050730). Material and Methods: A systematic literature search was conducted adhering to PRISMA guidelines to identify studies on implant impressions published between 2012 and 2017. Experimental and clinical studies at all levels of evidence published in peer-reviewed journals were included, excluding expert opinions. Data extraction was performed along defined parameters for studied specimens, digital and conventional impression specifications and outcome assessment. Results: Seventy-nine studies were included for the systematic review, thereof 77 experimental studies, one RCT and one retrospective study. The study setting was in vitro for most of the included studies (75 studies) and in vivo for four studies. Accuracy of conventional impressions was examined in 59 studies, whereas digital impressions were examined in 11 studies. Nine studies compared the accuracy of conventional and digital implant impressions. Reported measurements for the accuracy include the following: (a) linear and angular deviations between reference models and test models fabricated with each impression technique; (b) three-dimensional deviations between impression posts and scan bodies respectively; and (c) fit of implant-supported frameworks, assessed by measuring marginal discrepancy along implant abutments.) Meta-analysis was performed of 62 studies. The results of conventional and digital implant impressions exhibited high values for heterogeneity. Conclusions: The available data for accuracy of digital and conventional implant impressions have a low evidence level and do not include sufficient data on in vivo application to derive clinical recommendations