642 research outputs found

    Coherent phenomena in mesoscopic systems

    Full text link
    A mesoscopic system of cylindrical geometry made of a metal or a semiconductor is shown to exhibit features of a quantum coherent state. It is shown that magnetostatic interaction can play an important role in mesoscopic systems leading to an ordered ground state. The temperature TT^{*} below the system exhibits long-range order is determined. The self-consistent mean field approximation of the magnetostatic interaction is performed giving the effective Hamiltonian from which the self-sustaining currents can be obtained. The relation of quantum coherent state in mesoscopic cylinders to other coherent systems like superconductors is discussed.Comment: REVTeX, 4 figures, in print in Supercond. Sci. Techno

    The CRISPR/Cas9 system sheds new lights on the biology of protozoan parasites

    Get PDF
    The CRISPR/Cas9 system, a natural defence system of bacterial organisms, has recently been used to modify genomes of the most important protozoa parasites. Successful genome manipulations with the CRISPR/Cas9 system are changing the present view of genetics in parasitology. The application of this system offers a major chance to overcome the current restriction in culturing, maintaining and analysing protozoan parasites, and allows dynamic analysis of parasite genes functions, leading to a better understanding of pathogenesis. CRISPR/Cas9 system will have a significant influence on the process of developing novel drugs and treatment strategies against protozoa parasites

    Possibility of long-range order in clean mesoscopic cylinders

    Full text link
    A microscopic Hamiltonian of the magnetostatic interaction is discussed. This long-range interaction can play an important role in mesoscopic systems leading to an ordered ground state. The self-consistent mean field approximation of the magnetostatic interaction is performed to give an effective Hamiltonian from which the spontaneous, self-sustaining currents can be obtained. To go beyond the mean field approximation the mean square fluctuation of the total momentum is calculated and its influence on self-sustaining currents in mesoscopic cylinders with quasi-1D and quasi-2D conduction is considered. Then, by the use of the microscopic Hamiltonian of the magnetostatic interaction for a set of stacked rings, the problem of long-range order is discussed. The temperature TT^{*} below which the system is in an ordered state is determined.Comment: 14 pages, REVTeX, 5 figures, in print in Phys. Rev.

    Femtosecond dynamics of electronic states in the Mott insulator 1T-TaS2 by time-resolved photoelectron spectroscopy

    No full text
    Photoexcitation of the Mott insulator 1T-TaS2 by an intense laser pulse leads to an ultrafast transition toward a gapless phase. Beside the collapse of the electronic gap, the sudden excitation of the charge density wave mode results into periodic oscillations of the electronic states. We employ time resolved photoelectron spectroscopy to monitor the rich dynamics of electrons and phonons during the relaxation toward equilibrium. The qualitative difference between the oscillatory dynamics of the charge density wave and the monotonic recovery of the electronic gap proves that 1T-TaS2 is indeed a Mott insulator. Moreover the quasi-instantaneous build up of mid gap states is in contrast with the retarded response expected from a Peierls insulating phase. Interestingly, the photoinduced electronic states in the midgap spectral region display a weak resonance that is reminiscent of a quasiparticle peak

    Electromagnetic Calorimeter for HADES

    Full text link
    We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton data, but are unknown in the energy range of planned experiments (2-10 GeV per nucleon). The calorimeter will improve the electron-hadron separation, and will be used for detection of photons from strange resonances in elementary and HI reactions. Detailed description of the detector layout, the support structure, the electronic readout and its performance studied via Monte Carlo simulations and series of dedicated test experiments is presented. The device will cover the total area of about 8 m^2 at polar angles between 12 and 45 degrees with almost full azimuthal coverage. The photon and electron energy resolution achieved in test experiments amounts to 5-6%/sqrt(E[GeV]) which is sufficient for the eta meson reconstruction with S/B ratio of 0.4% in Ni+Ni collisions at 8 AGeV. A purity of the identified leptons after the hadron rejection, resulting from simulations based on the test measurements, is better than 80% at momenta above 500 MeV/c, where time-of-flight cannot be used.Comment: 40 pages, 38 figures version2 - the time schedule added, information about PMTs in Sec.III update

    Total Cross Sections for Neutron Scattering

    Get PDF
    Measurements of neutron total cross-sections are both extensive and extremely accurate. Although they place a strong constraint on theoretically constructed models, there are relatively few comparisons of predictions with experiment. The total cross-sections for neutron scattering from 16^{16}O and 40^{40}Ca are calculated as a function of energy from 5070050-700~MeV laboratory energy with a microscopic first order optical potential derived within the framework of the Watson expansion. Although these results are already in qualitative agreement with the data, the inclusion of medium corrections to the propagator is essential to correctly predict the energy dependence given by the experiment.Comment: 10 pages (Revtex 3.0), 6 fig

    Spin measurements for 147Sm+n resonances: Further evidence for non-statistical effects

    Full text link
    We have determined the spins J of resonances in the 147Sm(n,gamma) reaction by measuring multiplicities of gamma-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 140 known resonances below En = 1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignments, together with previously determined resonance parameters, allowed us to extract separate level spacings and neutron strength functions for J = 3 and 4 resonances. Furthermore, several statistical test of the data indicate that very few resonances of either spin have been missed below En = 700eV. Because a non-statistical effect recently was reported near En = 350 eV from an analysis of 147Sm(n,alpha) data, we divided the data into two regions; 0 < En < 350 eV and 350 < En < 700 eV. Using neutron widths from a previous measurement and published techniques for correcting for missed resonances and for testing whether data are consistent with a Porter-Thomas distribution, we found that the reduced-neutron-width distribution for resonances below 350 eV is consistent with the expected Porter-Thomas distribution. On the other hand, we found that reduced-neutron-width data in the 350 < En < 700 eV region are inconsistent with a Porter-Thomas distribution, but in good agreement with a chi-squared distribution having two or more degrees of freedom. We discuss possible explanations for these observed non-statistical effects and their possible relation to similar effects previously observed in other nuclides.Comment: 40 pages, 13 figures, accepted by Phys. Rev.

    Fast-Neutron Activation of Long-Lived Isotopes in Enriched Ge

    Full text link
    We measured the production of \nuc{57}{Co}, \nuc{54}{Mn}, \nuc{68}{Ge}, \nuc{65}{Zn}, and \nuc{60}{Co} in a sample of Ge enriched in isotope 76 due to high-energy neutron interactions. These isotopes, especially \nuc{68}{Ge}, are critical in understanding background in Ge detectors used for double-beta decay experiments. They are produced by cosmogenic-neutron interactions in the detectors while they reside on the Earth's surface. These production rates were measured at neutron energies of a few hundred MeV. We compared the measured production to that predicted by cross-section calculations based on CEM03.02. The cross section calculations over-predict our measurements by approximately a factor of three depending on isotope. We then use the measured cosmic-ray neutron flux, our measurements, and the CEM03.02 cross sections to predict the cosmogenic production rate of these isotopes. The uncertainty in extrapolating the cross section model to higher energies dominates the total uncertainty in the cosmogenic production rate.Comment: Revised after feedback and further work on extrapolating cross sections to higher energies in order to estimate cosmic production rates. Also a numerical error was found and fixed in the estimate of the Co-57 production rat

    Safety and efficacy of an engineered hepatotropic AAV gene therapy for ornithine transcarbamylase deficiency in cynomolgus monkeys

    Get PDF
    X-linked inherited ornithine transcarbamylase deficiency (OTCD) is the most common disorder affecting the liver-based urea cycle, a pathway enabling detoxification of nitrogen waste and endogenous arginine biosynthesis. Patients develop acute hyperammonemia leading to neurological sequelae or death despite the best-accepted therapy based on ammonia scavengers and protein-restricted diet. Liver transplantation is curative but associated with procedure-related complications and lifelong immunosuppression. Adeno-associated viral (AAV) vectors have demonstrated safety and clinical benefits in a rapidly growing number of clinical trials for inherited metabolic liver diseases. Engineered AAV capsids have shown promising enhanced liver tropism. Here, we conducted a good-laboratory practice-compliant investigational new drug-enabling study to assess the safety of intravenous liver-tropic AAVLK03 gene transfer of a human codon-optimized OTC gene. Juvenile cynomolgus monkeys received vehicle and a low and high dose of vector (2 × 1012 and 2 × 1013 vector genome (vg)/kg, respectively) and were monitored for 26 weeks for in-life safety with sequential liver biopsies at 1 and 13 weeks post-vector administration. Upon completion of monitoring, animals were euthanized to study vector biodistribution, immune responses, and histopathology. The product was well tolerated with no adverse clinical events, predominant hepatic biodistribution, and sustained supra-physiological OTC overexpression. This study supports the clinical deployment of intravenous AAVLK03 for severe OTCD
    corecore