20,293 research outputs found

    Scotin, a novel p53-inducible proapoptotic protein located in the ER and the nuclear membrane

    Get PDF
    p53 is a transcription factor that induces growth arrest or apoptosis in response to cellular stress. To identify new p53-inducible proapoptotic genes, we compared, by differential display, the expression of genes in spleen or thymus of normal and p53 nullizygote mice after γ-irradiation of whole animals. We report the identification and characterization of human and mouse Scotin homologues, a novel gene directly transactivated by p53. The Scotin protein is localized to the ER and the nuclear membrane. Scotin can induce apoptosis in a caspase-dependent manner. Inhibition of endogenous Scotin expression increases resistance to p53-dependent apoptosis induced by DNA damage, suggesting that Scotin plays a role in p53-dependent apoptosis. The discovery of Scotin brings to light a role of the ER in p53-dependent apoptosis

    DeepEar: Robust smartphone audio sensing in unconstrained acoustic environments using deep learning

    Get PDF
    Microphones are remarkably powerful sensors of human behavior and context. However, audio sensing is highly susceptible to wild fluctuations in accuracy when used in diverse acoustic environments (such as, bedrooms, vehicles, or cafes), that users encounter on a daily basis. Towards addressing this challenge, we turn to the field of deep learning; an area of machine learning that has radically changed related audio modeling domains like speech recognition. In this paper, we present DeepEar – the first mobile audio sensing framework built from coupled Deep Neural Networks (DNNs) that simultaneously perform common audio sensing tasks. We train DeepEar with a large-scale dataset including unlabeled data from 168 place visits. The resulting learned model, involving 2.3M parameters, enables DeepEar to significantly increase inference robustness to background noise beyond conventional approaches present in mobile devices. Finally, we show DeepEar is feasible for smartphones by building a cloud-free DSP-based prototype that runs continuously, using only 6% of the smartphone’s battery dailyThis is the author accepted manuscript. The final version is available from ACM via http://dx.doi.org/10.1145/2750858.280426

    Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

    Get PDF
    A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests

    Efficient Simulation of Quantum State Reduction

    Get PDF
    The energy-based stochastic extension of the Schrodinger equation is a rather special nonlinear stochastic differential equation on Hilbert space, involving a single free parameter, that has been shown to be very useful for modelling the phenomenon of quantum state reduction. Here we construct a general closed form solution to this equation, for any given initial condition, in terms of a random variable representing the terminal value of the energy and an independent Brownian motion. The solution is essentially algebraic in character, involving no integration, and is thus suitable as a basis for efficient simulation studies of state reduction in complex systems.Comment: 4 pages, No Figur

    Decomposing the Sources of Earnings Inequality: Assessing the Role of Reallocation

    Get PDF
    This paper exploits longitudinal employer-employee matched data from the U.S. Census Bureau to investigate the contribution of worker and firm reallocation to changes in earnings inequality within and across industries between 1992 and 2003. We find that factors that cannot be measured using standard cross-sectional data, including the entry and exit of firms and the sorting of workers across firms, are important sources of changes in earnings distributions over time. Our results also suggest that the dynamics driving changes in earnings inequality are heterogeneous across industries.inequality, linked employer-employee data, sorting

    AAOmega spectroscopy of 29 351 stars in fields centered on ten Galactic globular clusters

    Full text link
    Galactic globular clusters have been pivotal in our understanding of many astrophysical phenomena. Here we publish the extracted stellar parameters from a recent large spectroscopic survey of ten globular clusters. A brief review of the project is also presented. Stellar parameters have been extracted from individual stellar spectra using both a modified version of the Radial Velocity Experiment (RAVE) pipeline and a pipeline based on the parameter estimation method of RAVE. We publish here all parameters extracted from both pipelines. We calibrate the metallicity and convert this to [Fe/H] for each star and, furthermore, we compare the velocities and velocity dispersions of the Galactic stars in each field to the Besan\c{c}on Galaxy model. We find that the model does not correspond well with the data, indicating that the model is probably of little use for comparisons with pencil beam survey data such as this.Comment: 6 pages, 5 figures, 4 tables. Accepted for publication in A&A. Data described in tables will be available on CDS (at http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/530/A31) once publishe

    Decomposing the Sources of Earnings Inequality Assessing the Role of Reallocation

    Get PDF
    This paper uses matched employer-employee data from the Longitudinal Employer Household Dynamics database to investigate the contribution of worker and firm reallocation to within industry changes in wage inequality between 1992 and 2003. We find that the entry and exit of firms and the sorting of workers and firms based on underlying worker "skills" are important determinants of changes in industry earnings distributions over time. Our results suggest that the underlying dynamics of earnings inequality are complex and are due to factors that cannot be measured in standard crosssectional data.

    Effectiveness of slow motion video compared to real time video in improving the accuracy and consistency of subjective gait analysis in dogs

    Get PDF
    Objective measures of canine gait quality via force plates, pressure mats or kinematic analysis are considered superior to subjective gait assessment (SGA). Despite research demonstrating that SGA does not accurately detect subtle lameness, it remains the most commonly performed diagnostic test for detecting lameness in dogs. This is largely because the financial, temporal and spatial requirements for existing objective gait analysis equipment makes this technology impractical for use in general practice. The utility of slow motion video as a potential tool to augment SGA is currently untested. To evaluate a more accessible way to overcome the limitations of SGA, a slow motion video study was undertaken. Three experienced veterinarians reviewed video footage of 30 dogs, 15 with a diagnosis of primary limb lameness based on history and physical examination, and 15 with no indication of limb lameness based on history and physical examination. Four different videos were made for each dog, demonstrating each dog walking and trotting in real time, and then again walking and trotting in 50% slow motion. For each video, the veterinary raters assessed both the degree of lameness, and which limb(s) they felt represented the source of the lameness. Spearman’s rho, Cramer’s V, and t-tests were performed to determine if slow motion video increased either the accuracy or consistency of raters’ SGA relative to real time video. Raters demonstrated no significant increase in consistency or accuracy in their SGA of slow motion video relative to real time video. Based on these findings, slow motion video does not increase the consistency or accuracy of SGA values. Further research is required to determine if slow motion video will benefit SGA in other ways

    Metric approach to quantum constraints

    Full text link
    A new framework for deriving equations of motion for constrained quantum systems is introduced, and a procedure for its implementation is outlined. In special cases the framework reduces to a quantum analogue of the Dirac theory of constrains in classical mechanics. Explicit examples involving spin-1/2 particles are worked out in detail: in one example our approach coincides with a quantum version of the Dirac formalism, while the other example illustrates how a situation that cannot be treated by Dirac's approach can nevertheless be dealt with in the present scheme.Comment: 13 pages, 1 figur
    corecore