509 research outputs found

    The Degree of Fat Unsaturation in the Tissue and Potential Immune Response of Broiler Fed Chlorella sp.

    Get PDF
    This study was carried out to investigate the effect of Chlorella sp. administered in the diet of broilers on the degree of fat unsaturation, ratio of EPA to AA in the tissue and potential immune response of broiler. A total of 90 heads of one-day-old Ross chicks were assigned in completely randomized design by 3 dietary treatments with 6 repetitions and 5 chicks in each pen. The diets were T1: control (basal diet without enrichment with Chlorella sp.); T2: basal diet enriched with 5-g of Chlorella sp./kg feed; T3: basal diet enriched with 10-g of Chlorella sp./kg feed.  Skinless breast meat was sampled for FA determination at d-36. Chickens were vaccinated at d-6 and d-17 with live vaccine against ND to activate antibodies production, and then 2 ml of blood was collected at d-24 for IgG and IgM quantification. Administration of Chlorella sp. in broiler’s diet had no significant effect on the degree of fat unsaturation, the ratio between EPA and AA contained in the breast muscle and the concentration of IgG and IgM of broiler. In conclusion administration of Chlorella sp. from tropical marine origin in the diet of broiler has no significant effect on the degree of fat unsaturation, ratio of EPA to AA in the tissue, and potential immune response of broiler. The culture temperature in which the Chlorella sp. was cultivated may affect the FA composition of Chlorella sp. (Animal Production 12(2): 96-99 (2010)Abbreviations: AA: arachidonic acid, ALA: α-linolenic acid, EPA: eicosapentaenoic acid, FA: fatty acids, LA: linoleic acid, PGE2: Prostaglandin E2, PUFA: polyunsaturated fatty acids, SFA: saturated fatty acidKey Words: antibody, broiler, Chlorella sp., fatty acid, PUF

    Effect of feeding fermentable fibrerich feedstuffs on meat quality with emphasis on chemical and sensory boar taint in entire male and female pigs

    Get PDF
    Skatole, androstenone and other compounds such as indole cause boar taint in entire male pork. However, female pigs also produce skatole and indole. The purpose of this experiment was to minimise boar taint and increase overall impression of sensory quality by feeding entire male and female pigs with fibrerich feedstuffs. The pigs have been fed three organic diets for either 1 or 2 weeks prior to slaughter of which two diets contained different fermentable fibre-rich feedstuffs – 10–13.3% dried chicory roots or 25% blue lupines. These two treatments were compared with pigs fed with an organic control diet for either 1 or 2 weeks prior to slaughter. Lupines significantly reduced skatole in blood and backfat for both genders after 1 week. Moreover, lupines showed negative impact on growth rate and feed conversion whilst chicory showed no significant differences in this respect. However, the indole concentration was significantly lower in chicory than lupine fed pigs. From a sensory perspective, chicory and lupine feeding reduced boar taint since odour and flavour of manure related to skatole and urine associated to androstenone were minimised. The level of boar taint in the entire male pigs was most effectively reduced after 14 days by both fibre-rich feeds while lupine had the largest influence on ‘‘boar” taint reduction in female pigs

    Fatty Acids Profile of Meat, Mucosal Siga Concentration and Production Index of Broiler as a Response to Chlorella SP. Administration in the Diet

    Full text link
    This study was carried out to investigate the effect of different levels of Chlorella sp. in the form ofmeal administrated in the diet of broilers throughout their life upon FA profile of the breast muscle,mucosal secretory IgA (sIgA) concentration and production index (PI) of broiler. Allotted in 18 pens, thetotal of 90 Ross day old chicks were assigned in completely randomized design by 3 of dietarytreatments (T1: control (basal diet without enrichment of Chlorella sp.); T2: basal diet enriched with 5-gChlorella sp./kg feed; T3): basal diet enriched with 10-g Chlorella sp./kg feed. At d-36, skinless breastmeat was collected for FA determination. Practical standard of vaccination was performed to activateantibodies production and at d-36 gut mucosa was collected for sIgA analysis. Chlorella sp.administration had no significant effect (P>0.05) on the FA profile of breast muscle, mucosal sIgAconcentration and producton index of broiler. In conclusion, the level and ratio between n-3 to n-6polyunsaturated fatty acids (PUFA) as well as the nature of dietary PUFA source determine tissue PUFAcomposition. Beside through eicosanoid, Chlorella sp. may affect mucosal sIgA production throughcytokines mediated effect. Although Chlorella sp. administration does not improve the production indexof broiler, this treatment may produce broiler meat with lower fat content

    COVID-19 coronavirus: recommended personal protective equipment for the orthopaedic and trauma surgeon

    Get PDF
    PURPOSE: With the COVID-19 crisis, recommendations for personal protective equipment (PPE) are necessary for protection in orthopaedics and traumatology. The primary purpose of this study is to review and present current evidence and recommendations for personal protective equipment and safety recommendations for orthopaedic surgeons and trauma surgeons. METHODS: A systematic review of the available literature was performed using the keyword terms “COVID-19”, “Coronavirus”, “surgeon”, “health-care workers”, “protection”, “masks”, “gloves”, “gowns”, “helmets”, and “aerosol” in several combinations. The following databases were assessed: Pubmed, Cochrane Reviews, Google Scholar. Due to the paucity of available data, it was decided to present it in a narrative manner. In addition, participating doctors were asked to provide their guidelines for PPE in their countries (Austria, Luxembourg, Switzerland, Germany, UK) for consideration in the presented practice recommendations. RESULTS: World Health Organization guidance for respiratory aerosol-generating procedures (AGPs) such as intubation in a COVID19 environment was clear and included the use of an FFP3 (filtering face piece level 3) mask and face protection. However, the recommendation for surgical AGPs, such as the use of high-speed power tools in the operating theatre, was not clear until the UK Public Health England (PHE) guidance of 27 March 2020. This guidance included FFP3 masks and face protection, which UK surgeons quickly adopted. The recommended PPE for orthopaedic surgeons, working in a COVID19 environment, should consist of level 4 surgical gowns, face shields or goggles, double gloves, FFP2-3 or N95-99 respirator masks. An alternative to the mask, face shield and goggles is a powered air-purifying respirator, particularly if the surgeons fail the mask fit test or are required to undertake a long procedure. However, there is a high cost and limited availabilty of these devices at present. Currently available surgical helmets and toga systems may not be the solution due to a permeable top for air intake. During the current COVID-19 crisis, it appeared that telemedicine can be considered as an electronic personal protective equipment by reducing the number of physical contacts and risk contamination. CONCLUSION: Orthopaedic and trauma surgery using power tools, pulsatile lavage and electrocautery are surgical aerosol-generating procedures and all body fluids contain virus particles. Raising awareness of these issues will help avoid occupational transmission of COVID-19 to the surgical team by aerosolization of blood or other body fluids and hence adequate PPE should be available and used during orthopaedic surgery. In addition, efforts have to be made to improve the current evidence in this regard

    Comparative analysis of current 3D printed acetabular titanium implants

    Get PDF
    BACKGROUND: The design freedom allowed by three-dimensional (3D) printing enables the production of acetabular off-the-shelf cups with complex porous structures. The only studies on these designs are limited to clinical outcomes. Our aim was to analyse and compare the designs of different 3D printed cups from multiple manufacturers (Delta TT, Trident II Tritanium and Mpact 3D Metal). METHODS: We analysed the outer surface of the cups using scanning electron microscopy (SEM) and assessed clinically relevant morphometric features of the lattice structures using micro-computed tomography (micro-CT). Dimensions related to the cup wall (solid, lattice and overall thickness) were also measured. Roundness and roughness of the internal cup surface were analysed with coordinate measuring machine (CMM) and optical profilometry. RESULTS: SEM showed partially molten titanium beads on all cups, significantly smaller on Trident II (27 μm vs ~ 70 μm, p < 0.0001). We found a spread of pore sizes, with median values of 0.521, 0.841 and 1.004 mm for Trident II, Delta TT and Mpact, respectively. Trident II was also significantly less porous (63%, p < 0.0001) than the others (Delta TT 72.3%, Mpact 76.4%), and showed the thinnest lattice region of the cup wall (1.038 mm, p < 0.0001), while Mpact exhibited the thicker solid region (4.880 mm, p < 0.0044). Similar roundness and roughness of the internal cup surfaces were found. CONCLUSION: This was the first study to compare the designs of different 3D printed cups. A variability in the morphology of the outer surface of the cups and lattice structures was found. The existence of titanium beads on 3D printed parts is a known by-product of the manufacturing process; however, their prevalence on acetabular cups used in patients is an interesting finding, since these beads may potentially be released in the body

    Evidence of structural cavities in 3D printed acetabular cups for total hip arthroplasty

    Get PDF
    The use of three‐dimensional (3D) printing to manufacture off‐the‐shelf titanium acetabular cups for hip arthroplasty has increased; however, the impact of this manufacturing technology is yet not fully understood. Although several studies have described the presence of structural cavities in 3D printed parts, there has been no analysis of full postproduction acetabular components. The aim of this study was to investigate the effect of 3D printing on the material structure of acetabular implants, first comparing different designs of 3D printed cups, second comparing 3D printed with conventionally manufactured cups. Two of the 3D printed cups were produced using electron beam melting (EBM), one using laser rapid manufacturing (LRM). The investigation was performed using X‐ray microcomputed tomography, imaging both the entire cups and samples sectioned from different regions of each cup. All 3D printed cups showed evidence of structural cavities; these were uniformly distributed in the volume of the samples and exhibited a prevalent spherical shape. The LRM‐manufactured cup had significantly higher cavity density (p = .0286), with a median of 21 cavities/mm^{3} compared to 3.5 cavities/mm^{3} for EBM cups. However, the cavity size was similar, with a median of 20 μm (p = .7385). The conventional cups showed a complete absence of distinguishable cavities. The presence of cavities is a known limitation of the 3D printing technology; however, it is noteworthy that we found them in orthopedic implants used in patients. Although this may impact their mechanical properties, to date, 3D printed cups have not been reported to encounter such failures

    Dimensional analysis of 3D-printed acetabular cups for hip arthroplasty using X-ray microcomputed tomography

    Get PDF
    Purpose Three-dimensional (3D) printing is increasingly used to produce orthopaedic components for hip arthroplasty, such as acetabular cups, which show complex lattice porous structures and shapes. However, limitations on the quality of the final implants are present; thus, investigations are needed to ensure adequate quality and patients safety. X-ray microcomputed tomography (micro-CT) has been recognised to be the most suitable method to evaluate the complexity of 3D-printed parts. The purpose of this study was to assess the reliability of a micro-CT analysis method comparing it with reference systems, such as coordinate measuring machine and electron microscopy. Design/methodology/approach 3D-printed acetabular components for hip arthroplasty (n = 2) were investigated. Dimensions related to the dense and porous regions of the samples were measured. The micro-CT scanning parameters (voltage – kV, current – µA) were optimised selecting six combinations of beam voltage and current. Findings Micro-CT showed good correlation and agreement with both coordinate measuring machine and scanning electron microscopy when optimal scanning parameters were selected (130 kV – 100 µA to 180 kV – 80 µA). Mean discrepancies of 50 µm (± 300) and 20 µm (± 60) were found between the techniques for dense and porous dimensions. Investigation method such as micro-CT imaging may help to better understand the impact of 3D printing manufacturing technology on the properties of orthopaedic implants. Originality/value The optimisation of the scanning parameters and the validation of this method with reference techniques may guide further analysis of similar orthopaedic components

    Assessment of the equivalence of a generic to a branded femoral stem.

    Get PDF
    AIMS: The aim of this study was to compare the design of the generic OptiStem XTR femoral stem with the established Exeter femoral stem. MATERIALS AND METHODS: We obtained five boxed, as manufactured, implants of both designs at random (ten in total). Two examiners were blinded to the implant design and independently measured the mass, volume, trunnion surface topography, trunnion roughness, trunnion cone angle, Caput-Collum-Diaphyseal (CCD) angle, femoral offset, stem length, neck length, and the width and roughness of the polished stem shaft using peer-reviewed methods. We then compared the stems using these parameters. RESULTS: We found that the OptiStems were lighter (p < 0.001), had a rougher trunnion surface (p < 0.001) with a greater spacing and depth of the machined threads (p < 0.001), had greater trunnion cone angles (p = 0.007), and a smaller radius at the top of the trunnion (p = 0.007). There was no difference in stem volume (p = 0.643), CCD angle (p = 0.788), offset (p = 0.993), neck length (p = 0.344), stem length (p = 0.808), shaft width (p = 0.058 to 0.720) or roughness of the polished surface (p = 0.536). CONCLUSION: This preliminary investigation found that whilst there were similarities between the two designs, the generic OptiStem is different to the branded Exeter design. Cite this article: Bone Joint J 2017;99-B:310-16