5,022 research outputs found
Experimental Values of the Surface Tension of Supercooled Water
The results of surface-tension measurements for supercooled water are presented. A total of 702 individual measurements of surface tension of triple-distilled water were made in the temperature range, 27 to -22.2 C, with 404 of these measurements at temperatures below 0 C. The increase in magnitude of surface tension with decreasing temperature, as indicated by measurements above 0 C, continues to -22.2 C. The inflection point in the surface-tension - temperature relation in the vicinity of 0 C, as indicated by the International Critical Table values for temperatures down to -8 C, is substantiated by the measurements in the temperature range, 0 to -22.2 C. The surface tension increases at approximately a linear rate from a value of 76.96+/-0.06 dynes per centimeter at -8 C to 79.67+/-0.06 dynes per centimeter at -22.2 C
A summary of meteorological conditions associated with aircraft icing and a proposed method of selecting design criterions for ice-protection equipment
Measurement and analysis of lightning induced voltages in aircraft electrical systems
Lightning induced voltages in aircraft electrical circuit
An evaluation of the relative fire hazards of jet A and jet B for commercial flight
The relative fire hazards of Jet A and Jet B aircraft fuels are evaluated. The evaluation is based on a consideration of the presence of and/or the generation of flammable mixtures in fuel systems, the ignition characteristics, and the flame propagation rates for the two fuel types. Three distinct aircraft operating regimes where fuel type may be a factor in fire hazards are considered. These are: (1) ground handling and refueling, (2) flight, and (3) crash. The evaluation indicates that the overall fire hazards for Jet A are less than for Jet B fuel
Photomicrographic Investigation of Spontaneous Freezing Temperatures of Supercooled Water Droplets
A photomicrographic technique for investigating eupercooled. water droplets has been devised and. used. to determine the spontaneous freezing temperatures of eupercooled. water droplets of the size ordinarily found. in the atmosphere. The freezing temperatures of 4527 droplets ranging from 8.75 to 1000 microns in diameter supported on a platinum surface and 571 droplets supported on copper were obtained. The average spontaneous freezing temperature decreased with decrease in the size of the droplets. The effect of size on the spontaneous freezing temperature was particularly marked below 60 microns. Frequency-distribution curves of the spontaneous freezing temperatures observed for droplets of a given size were obtained. Although no droplet froze at a temperature above 20 0 F, all droplets melted at 32 F. Results obtained with a copper support did not differ essentially from those obtained with a platinum surface
The neural antecedents to voluntary action: Response to commentaries
Cognitive neuroscience must attend to the conceptual coherence of its hypotheses as well as to their empirical support. Examining the most influential studies of the neural antecedents to voluntary action, our Discussion Paper sought to identify the real-world consequences of neglecting the former in what we argued has been too narrow a pursuit of the latter. Though conceptual in form, our analysis is sharply empirical in its conclusions, revealing what have long been thought to be momentous experimental observations-such as the readiness potential-as the outcome of previously unidentified confounds that rob them of significance. Conversely, we suggested that experimental studies of two-way control, amongst other defining features of the voluntary, have been given less emphasis than the subject demands. Here, we ramify our analysis down the paths identified by others in the commentaries we received
A 100-element planar Schottky diode grid mixer
The authors present a Schottky diode grid mixer suitable for mixing or detecting quasi-optical signals. The mixer is a planar bow-tie grid structure periodically loaded with diodes. A simple transmission line model is used to predict the reflection coefficient of the grid to a normally incident plane wave. The grid mixer power handling and dynamic range scales as the number of devices in the grid. A 10-GHz 100-element grid mixer has shown an improvement in dynamic range of 16.3 to 19.8 dB over an equivalent single-diode mixer. The conversion loss and noise figure of the grid are equal to those of a conventional mixer. The quasi-optical coupling of the input signals makes the grid mixer suitable for millimeter-wave and submillimeter-wave applications by eliminating waveguide sidewall losses and machining difficulties. The planar property of the grid potentially allows thousands of devices to be integrated monolithically
GeoCLEF 2006: the CLEF 2006 Ccross-language geographic information retrieval track overview
After being a pilot track in 2005, GeoCLEF advanced to be a regular track within CLEF 2006. The
purpose of GeoCLEF is to test and evaluate cross-language geographic information retrieval (GIR): retrieval for
topics with a geographic specification. For GeoCLEF 2006, twenty-five search topics were defined by the
organizing groups for searching English, German, Portuguese and Spanish document collections. Topics were
translated into English, German, Portuguese, Spanish and Japanese. Several topics in 2006 were significantly
more geographically challenging than in 2005. Seventeen groups submitted 149 runs (up from eleven groups and
117 runs in GeoCLEF 2005). The groups used a variety of approaches, including geographic bounding boxes,
named entity extraction and external knowledge bases (geographic thesauri and ontologies and gazetteers)
Transition to Turbulence in Shear above the Tropopause
2000 FLORIDA AVE NW, WASHINGTON, USA, DC,
2000
Recycling Argon through Metamorphic Reactions: the Record in Symplectites
The 40Ar/39Ar ages of metamorphic micas that crystallized at high temperatures are commonly interpreted as cooling ages, with grains considered to have lost 40Ar via thermally-driven diffusion into the grain boundary network. Recently reported laser-ablation data suggest that the spatial distribution of Ar in metamorphic micas does not always conform to the patterns predicted by diffusion theory and that despite high metamorphic temperatures, argon was not removed efficiently from the local system during metamorphic evolution. In the Western Gneiss Region (WGR), Norway, felsic gneisses preserve microtextural evidence for the breakdown of phengite to biotite and plagioclase symplectites during near isothermal decompression from c. 20–25 to c. 8–12 kbar at ~700°C. These samples provide an ideal natural laboratory to assess whether the complete replacement of one K-bearing mineral by another at high temperatures completely ‘resets’ the Ar clock, or whether there is some inheritance of 40Ar in the neo-crystallized phase. The timing of the high-temperature portion of the WGR metamorphic cycle has been well constrained in previous studies. However, the timing of cooling following the overprint is still much debated. In-situ laser ablation spot dating in phengite, biotite-plagioclase symplectites and coarser, texturally later biotite yielded 40Ar/39Ar ages that span much of the metamorphic cycle. Together these data show that despite residence at temperatures of ~700°C, Ar is not completely removed by diffusive loss or during metamorphic recrystallization. Instead, Ar released during phengite breakdown appears to be partially reincorporated into the newly crystallizing biotite and plagioclase (or is trapped in fluid inclusions in those phases) within a close system. Our data show that the microtextural and petrographic evolution of the sample being dated provides a critical framework in which local 40Ar recycling can be tracked, thus potentially allowing 40Ar/39Ar dates to be linked more accurately to metamorphic history
- …
