137 research outputs found

    Patient Acceptance of Noninvasive and Invasive Coronary Angiography

    Get PDF
    BACKGROUND: Noninvasive angiography using multislice computed tomography (MSCT) is superior to magnetic resonance imaging (MRI) for detection of coronary stenoses. We compared patient acceptance of these two noninvasive diagnostic tests and invasive conventional coronary angiography (Angio). METHODS AND FINDINGS: A total of 111 consecutive patients with suspected coronary artery disease underwent MSCT, MRI, and Angio. Subsequently, patient acceptance of the three tests was evaluated with questionnaires in all patients. The main acceptance variables were preparation and information prior to the test, degree of concern, comfort, degree of helplessness, pain (on visual analog scales), willingness to undergo the test again, and overall satisfaction. Preparation for each test was not rated significantly differently, whereas patients were significantly more concerned about Angio than the two noninvasive tests (p<0.001). No pain during MSCT, MRI, and Angio as assessed on visual analog scales (0 to 100) was reported by 99, 93, and 31 patients, respectively. Among the 82 patients who felt pain during at least one procedure, both CT (0.9±4.5) and MRI (5.2±16.6) were significantly less painful than Angio (24.6±23.4, both p<0.001). MSCT was considered significantly more comfortable (1.49±0.64) than MRI (1.75±0.81, p<0.001). In both the no-revascularization (55 patients) and the revascularization group (56 patients), the majority of the patients (73 and 71%) would prefer MSCT to MRI and Angio for future imaging of the coronary arteries. None of the patients indicated to be unwilling to undergo MSCT again. The major advantages patients attributed to MSCT were its fast, uncomplicated, noninvasive, and painless nature. CONCLUSIONS: Noninvasive coronary angiography with MSCT is considered more comfortable than MRI and both MSCT and MRI are less painful than Angio. Patient preference for MSCT might tip the scales in favor of this test provided that the diagnostic accuracy of MSCT can be shown to be high enough for clinical application

    Contrast-induced acute kidney injury and renal support for acute kidney injury: A KDIGO summary (Part 2)

    Get PDF
    Acute kidney injury (AKI) is a common and serious problem affecting millions and causing death and disability for many. In 2012, Kidney Disease: Improving Global Outcomes completed the first ever international multidisciplinary clinical practice guideline for AKI. The guideline is based on evidence review and appraisal, and covers AKI definition, risk assessment, evaluation, prevention, and treatment. Two topics, contrast-induced AKI and management of renal replacement therapy, deserve special attention because of the frequency in which they are encountered and the availability of evidence. Recommendations are based on systematic reviews of relevant trials. Appraisal of the quality of the evidence and the strength of recommendations followed the Grading of Recommendations Assessment, Development and Evaluation approach. Limitations of the evidence are discussed and a detailed rationale for each recommendation is provided. This review is an abridged version of the guideline and provides additional rationale and commentary for those recommendation statements that most directly impact the practice of critical care. © 2013 BioMed Central Ltd

    Diagnosis, evaluation, and management of acute kidney injury: A KDIGO summary (Part 1)

    Get PDF
    Acute kidney injury (AKI) is a common and serious problem affecting millions and causing death and disability for many. In 2012, Kidney Disease: Improving Global Outcomes completed the first ever, international, multidisciplinary, clinical practice guideline for AKI. The guideline is based on evidence review and appraisal, and covers AKI definition, risk assessment, evaluation, prevention, and treatment. In this review we summarize key aspects of the guideline including definition and staging of AKI, as well as evaluation and nondialytic management. Contrast-induced AKI and management of renal replacement therapy will be addressed in a separate review. Treatment recommendations are based on systematic reviews of relevant trials. Appraisal of the quality of the evidence and the strength of recommendations followed the Grading of Recommendations Assessment, Development and Evaluation approach. Limitations of the evidence are discussed and a detailed rationale for each recommendation is provided. © 2013 BioMed Central Ltd

    Iodine contrast agents do not influence Platelet-Rich Plasma function at an early time point in vitro

    Get PDF
    BACKGROUND: Iodine contrast agents (ICAs) are routinely used by radiologists to help guide intra-articular infiltrations. The aim of this study was to assess the in vitro effects of ICA on platelet function of human autologous Platelet-Rich Plasma (PRP). METHODS: One hundred thirty-seven consecutive patients with symptomatic femoral-patellar osteoarthritis were included. All were addressed to our institution for a fluoroscopy-guided intra-articular PRP infiltration of the pathological femoral-patellar joint. For each patient, 500 μl of PRP were sampled before intra-articular injection. First, PRP samples were mixed with 50 μl of 2 widely used ICA: Visipaque270® (Iodixanol, n = 58) and Iopamiron200® (Iopamidol, n = 69). PRP concentration ([PRP]) was measured at different delays of incubation (t = 0, 5, 10, 15, 20 and 30 min) enabling to calculate PRP ratio (defined as [PRP](t)/[PRP](0mn)) at each delay, for each mixture, in order to quantitatively assess the influence of ICA on PRP ratio. Second, the PRP samples of 10 additional patients were mixed with Visipaque270®, Visipaque270®, Iopamiron200® and phosphate buffer saline (PBS: control solution) in order to qualitatively assess the influence of ICA on platelet aggregation, using ADP, Collagen, Arachidonic acid and TRAP tests. The surface expression of human P-selectin, a marker of α-granule release, in the PRP + Visipaque270® and PRP + Iopamiron200® mixtures was finally compared. Repeated-measures ANOVA, classical 2-way ANOVA and Wilcoxon matched-pairs test were used to study the influence of ICA on PRP quality. RESULTS: There was no significant change in PRP ratio during the first 30mn of incubation (p = 0.991) whatever the ICA (p = 0.926). Whatever the aggregation test, there was no significant difference in the percentage of platelet aggregation between PRP + PBS, PRP + Visipaque270® and PRP + Iopamiron200® (p = 0.998), nor between PRP + PBS and PRP + Visipaque320® (p = 0.470). Finally, there was no significant difference in P-selectin expression between the PRP + Visipaque270® and PRP + Iopamiron200® mixtures (p = 0.500). CONCLUSION: At early delays of incubation, Visipaque® and Iopamiron®, which are two widely used ICA for intra-articular infiltrations, did not influence the in vitro platelet function nor the quality of PRP

    N-acetylcysteine does not prevent contrast-induced nephropathy after cardiac catheterization in patients with diabetes mellitus and chronic kidney disease: a randomized clinical trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients with diabetes mellitus (DM) and chronic kidney disease (CKD) constitute to be a high-risk population for the development of contrast-induced nephropathy (CIN), in which the incidence of CIN is estimated to be as high as 50%. We performed this trial to assess the efficacy of <it>N</it>-acetylcysteine (NAC) in the prevention of this complication.</p> <p>Methods</p> <p>In a prospective, double-blind, placebo controlled, randomized clinical trial, we studied 90 patients undergoing elective diagnostic coronary angiography with DM and CKD (serum creatinine ≥ 1.5 mg/dL for men and ≥ 1.4 mg/dL for women). The patients were randomly assigned to receive either oral NAC (600 mg BID, starting 24 h before the procedure) or placebo, in adjunct to hydration. Serum creatinine was measured prior to and 48 h after coronary angiography. The primary end-point was the occurrence of CIN, defined as an increase in serum creatinine ≥ 0.5 mg/dL (44.2 μmol/L) or ≥ 25% above baseline at 48 h after exposure to contrast medium.</p> <p>Results</p> <p>Complete data on the outcomes were available on 87 patients, 45 of whom had received NAC. There were no significant differences between the NAC and placebo groups in baseline characteristics, amount of hydration, or type and volume of contrast used, except in gender (male/female, 20/25 and 34/11, respectively; P = 0.005) and the use of statins (62.2% and 37.8%, respectively; P = 0.034). CIN occurred in 5 out of 45 (11.1%) patients in the NAC group and 6 out of 42 (14.3%) patients in the placebo group (P = 0.656).</p> <p>Conclusion</p> <p>There was no detectable benefit for the prophylactic administration of oral NAC over an aggressive hydration protocol in patients with DM and CKD.</p> <p>Trial registration</p> <p>NCT00808795</p

    Contrast medium-induced nephropathy. Aspects on incidence, consequences, risk factors and prevention

    Get PDF
    Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of I-CM has contributed to an increasing number of CIN cases during the last few years. Reduced renal function, especially when caused by diabetic nephropathy or renal arteriosclerosis, in combination with dehydration, congestive heart failure, hypotension, and administration of nephrotoxic drugs are risk factors for the development of CIN. When CM-based examinations cannot be replaced by other techniques in patients at risk of CIN, focus should be directed towards analysis of number and type of risk factors, adequate estimation of GFR, institution of proper preventive measures including hydration and post-procedural observation combined with surveillance of serum creatinine for 1-3 days. For the radiologist, there are several steps to consider in order to minimise the risk for CIN: use of “low-“ or “iso-osmolar” I-CM and dosing the I-CM in relation to GFR and body weight being the most important as well as utilizing radiographic techniques to keep the I-CM dose in gram iodine as low as possible below the numerical value of estimated GFR. There is as yet no pharmacological prevention that has been proven to be effective
    corecore