6,245 research outputs found
Broken-symmetry-adapted Green function theory of condensed matter systems:towards a vector spin-density-functional theory
The group theory framework developed by Fukutome for a systematic analysis of
the various broken symmetry types of Hartree-Fock solutions exhibiting spin
structures is here extended to the general many body context using spinor-Green
function formalism for describing magnetic systems. Consequences of this theory
are discussed for examining the magnetism of itinerant electrons in nanometric
systems of current interest as well as bulk systems where a vector spin-density
form is required, by specializing our work to spin-density-functional
formalism. We also formulate the linear response theory for such a system and
compare and contrast them with the recent results obtained for localized
electron systems. The various phenomenological treatments of itinerant magnetic
systems are here unified in this group-theoretical description.Comment: 17 page
Smectic layer rotation by dc field in ferroelectric liquid crystal
This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in K. Nakayama, M. Ozaki, and K. Yoshino, Appl. Phys. Lett. 70, 2117 (1997) and may be found at https://doi.org/10.1063/1.118966
Search for magnetic monopoles using proportional counters filled with helium gas
Slow magnetic monopoles in cosmic rays have been searched at sea level with the detector which consists of seven layers of proportional counters filled with a mixture of He + 20% CH4. The velocities and the energy losses of the incident particles are measured. The upper limit of flux for the monopoles in the velocity range of 1 x 0.001 Beta 4 x 0.001 is 2.78 x 10 to the minus 12th power square centimeters sr sec of 90% confidence level
Virulence of Escherichia coli Isolates Obtained from Layer Chickens with Colibacillosis Associated with Pericarditis, Perihepatitis, and Salpingitis in Experimentally Infected Chicks and Embryonated Eggs
To evaluate the virulence of avian pathogenic Escherichia coli (APEC) isolates obtained from colibacillosis cases associated with pericarditis, perihepatitis, and salpingitis, the embryo lethality assay and experimental infection model in chicks were used in this study. According to the established criteria based on mortality in the embryo lethality assay for evaluating the virulence of E. coli isolates, 23 of the 26 APEC isolates associated with pericarditis and perihepatitis and 8 of the 20 isolates associated with salpingitis were found to be virulent. Isolate D137, which had been obtained from a case with pericarditis and perihepatitis and had an embryo mortality of 92%, and isolate D445, which had been obtained from a case with pericarditis and perihepatitis and had an embryo mortality of 17%, were used for the experimental infection. Four of the five 11-day-old chickens inoculated through the air sac with isolate D137 died 1 day postinoculation, and the challenge strain was recovered from the air sac, pericardial sac, or liver; however, colibacillosis lesions were found in only one of the five birds postmortem. All five chicks inoculated with isolate D445 survived for 7 days postinoculation and exhibited airsacculitis or pericarditis lesions at 7 days postinoculation; the challenge strain was not recovered from the lesions postmortem. The results obtained in this study suggest that the different APEC isolates tested cause illness in chickens through distinct pathogenesis
High-precision CTE measurement of hybrid C/SiC composite for cryogenic space telescopes
This paper presents highly precise measurements of thermal expansion of a
"hybrid" carbon-fiber reinforced silicon carbide composite,
HB-Cesic\textregistered - a trademark of ECM, in the temperature region of
\sim310-10K. Whilst C/SiC composites have been considered to be promising for
the mirrors and other structures of space-borne cryogenic telescopes, the
anisotropic thermal expansion has been a potential disadvantage of this
material. HB-Cesic\textregistered is a newly developed composite using a
mixture of different types of chopped, short carbon-fiber, in which one of the
important aims of the development was to reduce the anisotropy. The
measurements indicate that the anisotropy was much reduced down to 4% as a
result of hybridization. The thermal expansion data obtained are presented as
functions of temperature using eighth-order polynomials separately for the
horizontal (XY-) and vertical (Z-) directions of the fabrication process. The
average CTEs and their dispersion (1{\sigma}) in the range 293-10K derived from
the data for the XY- and Z-directions were 0.8050.003\times10
K and 0.837\pm0.001\times10 K, respectively. The absolute
accuracy and the reproducibility of the present measurements are suggested to
be better than 0.01\times10 K and 0.001\times(10)^{-6} K^{-1},
respectively. The residual anisotropy of the thermal expansion was consistent
with our previous speculation regarding carbon-fiber, in which the residual
anisotropy tended to lie mainly in the horizontal plane.Comment: Accepted by Cryogeincs. 12 pages, 3 figures, 1 tabll
- âŠ