451 research outputs found

    Molybdenum isotope and trace metal signals in an iron-rich Mesoproterozoic ocean: A snapshot from the Vindhyan Basin, India

    Get PDF
    Fundamental questions persist regarding the redox structure and trace metal content of the Mesoproterozoic oceans. Multiple lines of evidence suggest more widespread anoxia in the deep oceans compared to today, and iron speciation indicates that anoxia was largely accompanied by dissolved ferrous iron (ferruginous conditions) rather than free sulfide (euxinia). Still, exceptions exist—euxinic conditions have been reported from some ocean margin and epeiric sea settings, and oxic conditions were reported in one deeper water environment and are also known from shallow waters. Constraining the temporal evolution of Mesoproterozoic marine redox structure is critical because it likely governed redox-sensitive trace metal availability, which in turn played a significant role in marine diazotrophy and the evolution of early eukaryotes. Here, we present a new, multi-proxy geochemical dataset from the ~1.2 Ga Bijaygarh Shale (Kaimur Group, Vindhyan Basin, India) emphasizing total organic carbon, iron speciation, and trace metal concentrations, as well as sulfur, nitrogen, and molybdenum isotopes. This unit was deposited in an open shelf setting near or just below storm wave base. Taken together, our data provide a unique snapshot of a biologically important shallow shelf setting during the Mesoproterozoic Era, which includes: 1) locally ferruginous waters below the zone of wave mixing, 2) muted enrichment of trace metals sensitive to general anoxia (e.g., chromium) and variable enrichment of trace metals sensitive to euxinia (e.g., molybdenum and, to a lesser extent, vanadium), 3) general sulfate limitation, and 4) nitrogen fixation by molybdenum-nitrogenase and a dominantly anaerobic nitrogen cycle in offshore settings. Differential patterns of trace metal enrichment are consistent with data from other basins and suggest a largely anoxic ocean with limited euxinia during the Mesoproterozoic Era. Our new molybdenum isotope data—the first such data from unambiguously marine shales deposited between 1.4 and 0.75 Ga—record values up to +1.18 ± 0.12‰ that are analogous to data from other Mesoproterozoic shale units. Ultimately, this study provides a broad, multi-proxy perspective on the redox conditions that accompanied early eukaryotic evolution

    Strontium- and calcium-containing, titanium-stabilised phosphate-based glasses with prolonged degradation for orthopaedic tissue engineering.

    Get PDF
    Strontium- and calcium-releasing, titanium-stabilised phosphate-based glasses with a controlled degradation rate are currently under development for orthopaedic tissue engineering applications. Ca and/or Sr were incorporated at varying concentrations in quaternary phosphate-based glasses, in order to promote osteoinduction. Ti was incorporated at a fixed concentration in order to prolong degradation. Glasses of the general formula (P2O5)-(Na2O)-(TiO2)-(CaO)-(SrO) were prepared via the melt-quench technique. The materials were characterised by energy-dispersive X-ray spectroscopy, X-ray diffraction, (31)P magic angle spinning nuclear magnetic resonance, Fourier transform infrared spectroscopy, differential thermal analysis and density determination. The dissolution rate in distilled water was determined by measuring mass loss, ion release and pH change over a two-week period. In addition, the cytocompatibility and alkaline phosphatase activity of an osteoblast-like cell line cultured on the surface of glass discs was assessed. The glasses were shown to be amorphous and contained Q(1), Q(2) and Q(3) species. Fourier transform infrared spectroscopy revealed small changes in the glass structure as Ca was substituted with Sr and differential thermal analysis confirmed a decrease in crystallisation temperature with increasing Sr content. Degradation and ion release studies also showed that mass loss was positively correlated with Sr content. These results were attributed to the lower electronegativity of Sr in comparison to Ca favouring the formation of phosphate-based mineral phases. All compositions supported cell proliferation and survival and induced at least 2.3-fold alkaline phosphatase activity relative to the control. Glass containing 17.5 mol% Sr had 3.6-fold greater alkaline phosphatase activity than the control. The gradual release of Ca and Sr supported osteoinduction, indicating their potential suitability in orthopaedic tissue engineering applications

    Quantum interferometry with three-dimensional geometry

    Get PDF
    Quantum interferometry uses quantum resources to improve phase estimation with respect to classical methods. Here we propose and theoretically investigate a new quantum interferometric scheme based on three-dimensional waveguide devices. These can be implemented by femtosecond laser waveguide writing, recently adopted for quantum applications. In particular, multiarm interferometers include "tritter" and "quarter" as basic elements, corresponding to the generalization of a beam splitter to a 3- and 4-port splitter, respectively. By injecting Fock states in the input ports of such interferometers, fringe patterns characterized by nonclassical visibilities are expected. This enables outperforming the quantum Fisher information obtained with classical fields in phase estimation. We also discuss the possibility of achieving the simultaneous estimation of more than one optical phase. This approach is expected to open new perspectives to quantum enhanced sensing and metrology performed in integrated photonic.Comment: 7 pages (+4 Supplementary Information), 5 figure

    Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012

    Get PDF
    BACKGROUND: Hip replacement and hip resurfacing are common surgical procedures with an estimated risk of revision of 4% over 10 year period. Approximately 58% of hip replacements will last 25 years. Some implants have higher revision rates and early identification of poorly performing hip replacement implant brands and cup/head brand combinations is vital. AIMS: Development of a dynamic monitoring method for the revision rates of hip implants. METHODS: Data on the outcomes following the hip replacement surgery between 2004 and 2012 was obtained from the National Joint Register (NJR) in the UK. A novel dynamic algorithm based on the CUmulative SUM (CUSUM) methodology with adjustment for casemix and random frailty for an operating unit was developed and implemented to monitor the revision rates over time. The Benjamini-Hochberg FDR method was used to adjust for multiple testing of numerous hip replacement implant brands and cup/ head combinations at each time point. RESULTS: Three poorly performing cup brands and two cup/ head brand combinations have been detected. Wright Medical UK Ltd Conserve Plus Resurfacing Cup (cup o), DePuy ASR Resurfacing Cup (cup e), and Endo Plus (UK) Limited EP-Fit Plus Polyethylene cup (cup g) showed stable multiple alarms over the period of a year or longer. An addition of a random frailty term did not change the list of underperforming components. The model with added random effect was more conservative, showing less and more delayed alarms. CONCLUSIONS: Our new algorithm is an efficient method for early detection of poorly performing components in hip replacement surgery. It can also be used for similar tasks of dynamic quality monitoring in healthcare

    Unnecessary use of fluoroquinolone antibiotics in hospitalized patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fluoroquinolones are among the most commonly prescribed antimicrobials and are an important risk factor for colonization and infection with fluoroquinolone-resistant gram-negative bacilli and for <it>Clostridium difficile </it>infection (CDI). In this study, our aim was to determine current patterns of inappropriate fluoroquinolone prescribing among hospitalized patients, and to test the hypothesis that longer than necessary treatment durations account for a significant proportion of unnecessary fluoroquinolone use.</p> <p>Methods</p> <p>We conducted a 6-week prospective, observational study to determine the frequency of, reasons for, and adverse effects associated with unnecessary fluoroquinolone use in a tertiary-care academic medical center. For randomly-selected adult inpatients receiving fluoroquinolones, therapy was determined to be necessary or unnecessary based on published guidelines or standard principles of infectious diseases. Adverse effects were determined based on chart review 6 weeks after completion of therapy.</p> <p>Results</p> <p>Of 1,773 days of fluoroquinolone therapy, 690 (39%) were deemed unnecessary. The most common reasons for unnecessary therapy included administration of antimicrobials for non-infectious or non-bacterial syndromes (292 days-of-therapy) and administration of antimicrobials for longer than necessary durations (234 days-of-therapy). The most common syndrome associated with unnecessary therapy was urinary tract infection or asymptomatic bacteriuria (30% of all unnecessary days-of-therapy). Twenty-seven percent (60/227) of regimens were associated with adverse effects possibly attributable to therapy, including gastrointestinal adverse effects (14% of regimens), colonization by resistant pathogens (8% of regimens), and CDI (4% of regimens).</p> <p>Conclusions</p> <p>In our institution, 39% of all days of fluoroquinolone therapy were unnecessary. Interventions that focus on improving adherence with current guidelines for duration of antimicrobial therapy and for management of urinary syndromes could significantly reduce overuse of fluoroquinolones.</p

    Prime movers : mechanochemistry of mitotic kinesins

    Get PDF
    Mitotic spindles are self-organizing protein machines that harness teams of multiple force generators to drive chromosome segregation. Kinesins are key members of these force-generating teams. Different kinesins walk directionally along dynamic microtubules, anchor, crosslink, align and sort microtubules into polarized bundles, and influence microtubule dynamics by interacting with microtubule tips. The mechanochemical mechanisms of these kinesins are specialized to enable each type to make a specific contribution to spindle self-organization and chromosome segregation

    Recommendations for laboratory workflow that better support centralised amalgamation of genomic variant data: findings from CanVIG-UK national molecular laboratory survey.

    Get PDF
    BACKGROUND: National and international amalgamation of genomic data offers opportunity for research and audit, including analyses enabling improved classification of variants of uncertain significance. Review of individual-level data from National Health Service (NHS) testing of cancer susceptibility genes (2002-2023) submitted to the National Disease Registration Service revealed heterogeneity across participating laboratories regarding (1) the structure, quality and completeness of submitted data, and (2) the ease with which that data could be assembled locally for submission. METHODS: In May 2023, we undertook a closed online survey of 51 clinical scientists who provided consensus responses representing all 17 of 17 NHS molecular genetic laboratories in England and Wales which undertake NHS diagnostic analyses of cancer susceptibility genes. The survey included 18 questions relating to 'next-generation sequencing workflow' (11), 'variant classification' (3) and 'phenotypical context' (4). RESULTS: Widely differing processes were reported for transfer of variant data into their local LIMS (Laboratory Information Management System), for the formatting in which the variants are stored in the LIMS and which classes of variants are retained in the local LIMS. Differing local provisions and workflow for variant classifications were also reported, including the resources provided and the mechanisms by which classifications are stored. CONCLUSION: The survey responses illustrate heterogeneous laboratory workflow for preparation of genomic variant data from local LIMS for centralised submission. Workflow is often labour-intensive and inefficient, involving multiple manual steps which introduce opportunities for error. These survey findings and adoption of the concomitant recommendations may support improvement in laboratory dataflows, better facilitating submission of data for central amalgamation
    • …
    corecore