9 research outputs found

    Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique

    Get PDF
    Aims Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. Methods and results The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P Conclusion The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications

    Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF).

    Get PDF
    AIMS Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement

    Novel cryoballoon to isolate pulmonary veins in patients with paroxysmal atrial fibrillation: long-term outcomes in a multicentre clinical study

    Get PDF
    Background: Recently, a novel cryoballoon ablation catheter has demonstrated acute safety and efficacy in de novo pulmonary vein isolation (PVI) procedures in patients with paroxysmal atrial fibrillation (PAF). However, there are limited studies demonstrating the long-term efficacy. The aim of this study was to evaluate the long-term safety and efficacy of this novel cryoballoon in treating PAF. Methods: This was a non-randomized, prospective, multicentre study enrolling 58 consecutive patients. Cryoablation was delivered for 180 s if time to isolation was ≤ 60 s. Otherwise a 240-s cryoablation was performed. One centre performed pre- and post-ablation high-density mapping (n = 9) to characterize lesion formation. After a 3-month blanking period, recurrence was defined as having any documented, symptomatic episode(s) of AF or atrial tachycardia. All patients were followed for 1 year. Results: Acute PVI was achieved in 230 of 231 pulmonary veins (99.6%) with 5.3 ± 1.6 cryoablations per patient (1.3 ± 0.7 cryoablations per vein). Forty-three (77%) patients remained arrhythmia-free at 1-year follow-up. Four patients (6.9%) experienced phrenic nerve injury (3 resolved during the index procedure; 1 resolved at 6 months). One serious adverse device event was reported: femoral arterial embolism event occurring 2 weeks post-index procedure. For patients who underwent high-density mapping, cryoablation was antral with 50% of the posterior wall ablated. Conclusions: Initial multicentre clinical experience with a novel cryoballoon has demonstrated safety and efficacy of PVI in patients with PAF. Ablation with this cryoballoon provides a wide, antral lesion set with significant debulking of the posterior wall of the left atrium

    EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation - Lessons from the multicenter EU-PORIA Registry.

    No full text
    BACKGROUND AND AIMS Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The multi-center EU-PORIA (EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multielectrode PFA catheter. METHODS All-comer AF patients from seven high-volume centers were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analyzed by operator ablation experience and primary ablation modality. RESULTS In total, 1,233 patients (61% male, mean age 66±11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n=127). Median procedure and fluoroscopy times were 58 [IQR: 40-87] and 14 [9-21] min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischemic attack or stroke (n=7; 0.6%), of which one was fatal. Prior cryo-balloon users had less complications. At a median follow-up of 365 [323-386] days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population

    Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry.

    No full text
    BACKGROUND Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (7 days) major adverse events. RESULTS At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF

    Clinical Outcomes by Sex After Pulsed Field Ablation of Atrial Fibrillation.

    No full text
    IMPORTANCE Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. OBJECTIVE To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. DESIGN, SETTING, AND PARTICIPANTS This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. EXPOSURE PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. MAIN OUTCOMES AND MEASURES The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (7 days) major adverse events (MAEs). RESULTS Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). CONCLUSION AND RELEVANCE Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events

    Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF)

    No full text
    Aims Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. Methods and results This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). Conclusion In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement

    STereotactic Arrhythmia Radioablation (STAR): the Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary consortium (STOPSTORM.eu) and review of current patterns of STAR practice in Europe.

    Get PDF
    The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs
    corecore