155 research outputs found

    Development of Precise Load Prediction System for Free Forging of Ni-based Superalloy having Softening

    Get PDF
    AbstractNi-based superalloys such as Alloy 706 that have high heat resistance are applied to gas turbine disks in electric power plant because. Free forging is one of the effective forging processes to form superalloy products, and forging simulation is quite useful method to optimize forging schedule. Softening behaviour at high temperature was not considered and implemented in conventional simulation, that induced the accuracy of load prediction. In this study, we investigated softening behaviour to improve the accuracy of forging simulation

    Ad4BP/SF-1 regulates cholesterol synthesis to boost the production of steroids

    Get PDF
    Housekeeping metabolic pathways such as glycolysis are active in all cell types. In addition, many types of cells are equipped with cell-specific metabolic pathways. To properly perform their functions, housekeeping and cell-specific metabolic pathways must function cooperatively. However, the regulatory mechanisms that couple metabolic pathways remain largely unknown. Recently, we showed that the steroidogenic cell-specific nuclear receptor Ad4BP/ SF-1, which regulates steroidogenic genes, also regulates housekeeping glycolytic genes. Here, we identify cholesterogenic genes as the targets of Ad4BP/SF-1. Further, we reveal that Ad4BP/SF-1 regulates Hummr, a candidate mediator of cholesterol transport from endoplasmic reticula to mitochondria. Given that cholesterol is the starting material for steroidogenesis and is synthesized from acetyl-CoA, which partly originates from glucose, our results suggest that multiple biological processes involved in synthesizing steroid hormones are governed by Ad4BP/SF-1. To our knowledge, this study provides the first example where housekeeping and cell-specific metabolism are coordinated at the transcriptional level.This work was supported by Grants 16H05142 (K.M.), 17H06427 (K.M.), 16K08593 (T.B.), and 17J03270 (M.I.) from the Japan Society for the Promotion of Science (JSPS) KAKENHI; The Uehara Memorial Foundation (K.M.); Takeda Science Foundation (T.B.); The Shin-Nihon of Advanced Medical Research (T.B.).Supplementary information accompanies this paper at https://doi.org/10.1038/s42003-018-0020-z

    Host selection of hematophagous leeches (Haemadipsa japonica): Implications for iDNA studies

    Get PDF
    The development of an efficient and cost‐effective method for monitoring animal populations or biodiversity is urgently needed, and invertebrate‐derived DNA (iDNA) may offer a promising tool for assessing the diversity and other ecological information of vertebrates. We studied the host species of a hematophagous leech (Haemadipsa japonica) in Yakushima by genetic barcoding and compared the results with those for mammal composition revealed by camera trapping. We analyzed 119 samples using two sets of primers by Sanger sequencing and one set of primer by next generation sequencing. The proportion of the samples that were successfully sequenced and identified to at least one species was 11.8–24.3%, depending on the three different methods. In all of these three methods, most of the samples were identified as sika deer (18/20, 6/15 and 16/29) or human (2/20, 7/15 and 21/29). The nonhuman mammal host species composition was significantly different from that estimated by camera trapping. Sika deer was the main host, which may be related with their high abundance, large body size and terrestriality. Ten samples included DNA derived from multiple species of vertebrates. This may be due to the contamination of human DNA, but we also found DNA from deer, Japanese macaque and a frog in the same samples, suggesting the mixture of the two meals in the gut of the leech. Using H. japonica‐derived iDNA would not be suitable to make an inventory of species, but it may be useful to collect genetic information on the targeted species, due to their high host selectivity

    Linguistic Factors Affecting Moraic Duration in Spontaneous Japanese

    Get PDF
    Japanese is often referred to as a mora-timed language (Ladefoged 1975): the mora has been described as the psychological prosodic unit in the spoken language, and it is the metric unit of traditional poetry (Bloch 1950). However, it is clear that mo- rae are not strictly isochronous units (Beckman 1982). Thus, experimental studies have focused on detecting compensation effects that make average mora durations more equal through the modulation of the inherent duration of the segments involved (Han 1962; Port, Al-Ani, Maeda 1980; Homma 1981; Hoequist 1983a; 1983b; Warner, Arai 2001). Kawahara (2017) used the Corpus of Spontaneous Japanese to verify whether the dura- tional compensation effect within a /CV/ mora occurs in natural speech, in addition to read speech in the lab. He observed a statistically significant compensation effect of /CV/ morae, in which vowel duration tends to vary in response to the duration of the preced- ing consonant. However, as the same author has pointed out, the compensation is not absolute because there are several linguistic factors that potentially affect segments’ duration profiles. This study will support the idea that moraic isochrony does not occur in spontaneous Japanese by presenting empirical data on how linguistic factors can considerably affect variation in the average duration of morae

    Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    Get PDF
    Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ∼10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. Methods: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. Results: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. Conclusions: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data

    A Novel Approach to Endoscopic Submucosal Dissection Using Bipolar Current Needle Knife for Colorectal Tumors

    Get PDF
    Objective: To completely and safely remove a large colorectal lesion in a single fragment, we have developed an endoscopic electrosurgical knife( B-Knife) for a more effective bipolar cutting adevelopedannd coagulation system.The aim of this study was to evaluate the effectiveness and safety of the B-Knife in patients with large colorectal tumors.Methods:Endoscopic submucosal dissection (ESD) using the B-Knife was performed initially in 3 patients with large colorectal tumors in a pilot study. Subsequently, we examined the clinical outcomes of ESDusing the B-Knife in 25 patients with colorectal tumors.Results:During initial clinical use of the B-Knife, en bloc resection was achieved in all 3 cases, and themean operating time was 43 minutes. All margins of resected material were histologically free of neoplasia.There were no cases of delayed bleeding or perforation. In a series of 25 ESD cases, which consisted of 8adenomas, 15 intramucosal carcinomas, one slightly submucosal invasive carcinoma, and one massive submucosalinvasive carcinoma, the en bloc resection rate was 84% . The mean operation time was 91.6 minutes and the mean size of resected specimens was 36.4 mm (range:19-80 mm). Perforations occurred in one( 4%) case, but delayed bleeding did not occur in any of the cases. Additional surgery was required for2 cases( 8%).Conclusions:ESD using the B-Knife is reliable and safe for the complete resection of select large flat lesions in the colorectum
    corecore