28 research outputs found

    Anti-immunoglobulin-like transcript 3 induced acute myocarditis—A case report

    Get PDF
    To the best of our knowledge, this is the first published report of anti-immunoglobulin-like transcript 3 (ILT3)-induced myocarditis. A 48-year old female patient with refractory acute myeloid leukemia who was given a single dose of anti-ILT3 monotherapy presented with fever, hypotension, chest pain, and elevated cardiac biomarkers. Systolic bi-ventricular function was in normal limits. The patient was promptly treated with pulse dose steroids with a rapid hemodynamic and clinical improvement and declining levels of cardiac biomarkers. The diagnosis of acute myocarditis was confirmed using cardiac magnetic resonance imaging applying the revised Lake Lewis criteria. While larger-scale data are needed in order to assess the incidence, management and prognosis of anti-ILT-3 induced myocarditis, we believe a high level of suspicion for adverse non-target cardiac effects is required in patients receiving this novel class of drugs

    Identifying patients at risk: multi-centre comparison of HeartMate 3 and HeartWare left ventricular assist devices

    Get PDF
    Aims: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. Methods and results: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P 2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. Conclusions: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation

    Identifying patients at risk: multi-centre comparison of HeartMate 3 and HeartWare left ventricular assist devices

    Get PDF
    AIMS: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. METHODS AND RESULTS: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P 2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. CONCLUSIONS: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation

    Identifying patients at risk: multi-centre comparison of HeartMate 3 and HeartWare left ventricular assist devices

    Get PDF
    AIMS: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. METHODS AND RESULTS: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P 2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. CONCLUSIONS: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation

    The Potential Cardiotoxicity of Immune Checkpoint Inhibitors

    No full text
    The use of immune checkpoint inhibitors (ICIs) as a mono- or adjuvant oncologic treatment is rapidly expanding to most fields of cancer. Alongside their efficacy, ICIs carry the risk of immune-related adverse events (irAEs) arising from misguided immune-mediated response to normal tissues. In the cardiovascular system, the cardiac toxicity of ICIs has been primarily related to the development of an acute, immune-mediated myocarditis; beyond this potentially fatal complication, evidence of an increased risk of cardiovascular events and accelerated atherosclerosis is emerging, as well as reports of other cardiovascular adverse events such as arrythmias, Takotsubo-like syndrome and vascular events. The absence of identified risk factors for cardiotoxic complications, specific monitoring strategies or diagnostic tests, pose challenges to the timely recognition and optimal management of such events. The rising numbers of patients being treated with ICIs make this potential cardiotoxic effect one of paramount importance for further investigation and understanding. This review will discuss the most recent data on different cardiotoxic effects of ICIs treatment

    Self-care behaviours of patients with left ventricular assist devices in Israel: changes during the COVID-19 pandemic

    No full text
    AimsLeft ventricular assist devices (LVADs) support the hearts of patients with advanced heart failure. Following LVAD implantation, patients face a complex regimen of self-care behaviours including self-care maintenance, self-care monitoring and self-care management. However, during the COVID-19 pandemic, symptoms of anxiety and depression may have interfered with their self-care. Currently, little is known on how specific self-care behaviours of LVAD-implanted patients changed during the COVID-19 pandemic. We aim to describe the changes in self-care behaviours among patients with an implanted LVAD in Israel during the COVID-19 pandemic and explore the factors related to self-care behaviour change. MethodsA prospective observational cross-sectional study design. A convenience sample of 27 Israeli LVAD-implanted patients (mean age 62.4 +/- 9, 86% male, 78.6% living with a partner) completed the LVAD Self-Care Behaviour Scale (1 = never to 5 = always) and Hospital Anxiety and Depression Scale (0 = not at all to 3 = most of the time). Data were collected before and after the onset of the COVID-19 pandemic in Israel. Statistical analyses included paired t-tests, Pearsons correlations, and one-way repeated measures ANOVAs. ResultsDuring the COVID-19 pandemic, a significant decrease was found in patients adherence to checking and recording their LVAD speed, flow, power and PI (Pulsatility Index) (P = 0.05), checking their INR (P = 0.01), and daily weighing (P &amp;lt; 0.01). The prevalence of some behaviours (e.g. regularly exercising) increased in some patients and decreased in others. Patients living without a partner worsened their adherence to some of the self-care behaviours (e.g. taking medicines as prescribed), compared with those living with a partner (M-b = 5.0 +/- 0 and M-d = 5.0 +/- 0, delta = 0 vs. M-b = 5.0 +/- 0 and M-d = 4.6 +/- 0.9, delta = -0.4, respectively; F = 4.9, P = 0.04). Women, and not men, tended to improve their adherence to the self-care behaviour such as avoiding kinking, pulling, or moving the LVAD driveline at the exit site (M-b = 4.0 +/- 1.0 and M-d = 5.0 +/- 0, delta = 1.0 vs. M-b = 4.5 +/- 0.9 and M-d = 4.4 +/- 1.2, delta = -0.1, F = 4.7, P = 0.04, respectively). In total, 41% (11) patients reported neither anxiety nor depression, 11% (3) reported anxiety, 15% (4) reported depression, and 44% (12) reported both anxiety and depression. No associations between anxiety and/or depression and self-care behaviours were found. ConclusionsPriorities in self-care behaviours among patients with implanted LVAD changed after the onset of the COVID-19 pandemic. Factors that assisted with adherence to self-care behaviours included living with a partner and being female. The current results may guide further research on identifying behaviours that are at risk of not being maintained during a time of emergency.Funding Agencies|Nursing &amp; Allied Professional Training Grant from the ESC (European Society ofCardiology)</p

    Cardiovascular Proteomics : A Post Hoc Analysis from a Phase II Randomized Clinical Trial Comparing GnRH Antagonist vs GnRH Agonist among Men with Advanced Prostate Cancer

    No full text
    PURPOSE: Recent studies demonstrated reduced cardiovascular (CV) risk with gonadotropin-releasing hormone (GnRH) antagonist, yet the underlying mechanism remains undetermined. The objective of this study was to examine longitudinal changes over time in established CV related proteins among men treated with GnRH agonists vs GnRH antagonist. MATERIALS AND METHODS: We performed a proteomics analysis of serum samples collected during a phase II randomized study among 80 men with advanced prostate cancer and preexisting CV disease who were randomized to receive a GnRH agonist (39) or GnRH antagonist (41) for 1 year. Serum samples were collected at baseline and at 3, 6 and 12 months following treatment, and analyzed levels of 188 proteins using the CV panel II and III of the Olink Multiplex platform (Olink Proteomics AB, Uppsala, Sweden). We fitted a linear mixed effects model to assess evidence of a treatment effect across CV related protein values. This included terms for treatment arm, protein levels and time-by-treatment interaction. Results were corrected for multiple testing using the Benjamini-Hochberg method. RESULTS: The CV proteomics analysis included 283 samples from 78 subjects. We identified 5 proteins with distinct patterns over time depending on study arm: human chitotriosidase, macrophage receptor with collagenous structure, cathepsin D, superoxide dismutase 2 and hydroxyacid oxidase 1. All 5 are associated with plaque stability and demonstrated an increased level among subjects in the GnRH antagonist arm compared to agonist. CONCLUSIONS: We compared longitudinal changes in CV proteins among men using androgen deprivation therapy. Our results support a direct protective effect of GnRH antagonist on plaque stability rather than a hazardous consequence of GnRH agonists on plaque rupture. This is a hypothesis generating study, and requires further confirmation

    Exergaming in patients with a left ventricular assist device : a feasibility study

    No full text
    Aims Exercise games (exergames) have been recently proposed as a mode of facilitating physical activity in patients with chronic diseases. Although patients supported with left ventricular assist devices (LVADs) benefit from physical activity, specific LVAD-related issues hinder their ability to exercise properly. The objective of this study was to assess the feasibility and safety of exergaming in LVAD-supported patients. Methods and results Eleven LVAD-supported patients were enrolled in a 4 week exergaming programme using Nintendo Wii console with five sport games. Patients were instructed to play for 30 min a day, 5 days a week. Data on exercise capacity and exergaming were collected by using the 6 min walk test (6MWT) and a daily self-report diary, respectively. Feasibility of using the console and its safety was assessed by a semi-structured patient interview. Quality of life was assessed by the Minnesota Living with Heart failure Questionnaire (MLHFQ) and the Cantrils Ladder of Life. Safety was assessed by patients report in interview and diary. The study group consisted of 10 male patients and 1 female patient, mean age of 67 +/- 7 years, of whom 10 were supported with the HeartMate 3 LVAD for a median of 10 (interquartile range 3, 21) months. Baseline exercise capacity assessed by the 6MWT ranged from 240 to 570 m (mean 448 +/- 112). After 4 weeks of exergaming, 6MWT distance increased from a mean of 448 +/- 112 (evaluated in six patients) to 472 +/- 113 m (P = 0.023). Patients Cantrils Ladder of Life score improved numerically from an average of 6.13 to 7.67, as did their MLHFQ score from 45.9 +/- 27 to 38.7 +/- 18, with higher and lower scores, respectively, reflecting higher quality of life. No specific LVAD-related safety issues regarding exergaming were reported. Conclusions Exergaming was found to be a safe and feasible mode for encouraging physical activity in LVAD-supported patients and carries a potential for improving exercise capacity and quality of life in these patients. Larger scale studies are warranted to further investigate the effect of exergaming in this patient population.Funding Agencies|Swedish National Science Council [2016-01390]</p

    Admission blood glucose and 10-year mortality among patients with or without pre-existing diabetes mellitus hospitalized with heart failure

    No full text
    Abstract Background High admission blood glucose (ABG) level has been associated with a poor short-term outcome among non-diabetic patients with heart failure (HF). We aimed to investigate the association between ABG levels and long-term (10 years) mortality in patients with or without pre-existing diabetes mellitus (DM) admitted with HF. Methods We analyzed data on 1811 patients with DM and 2182 patients without pre-existing DM who were hospitalized with HF during a prospective national survey. The relationship between ABG and 10-year mortality was assessed using the Cox proportional hazard model adjusting for multiple variables. ABG was analyzed both as a categorical (200 mg/dL) and as a continuous variable. Results At 10 years of follow-up the cumulative probability of mortality was 85 and 78% among patients with DM and patients with no pre-existing DM (p 200 mg/dL had an increased mortality risk (>200 mg/dL versus 200 mg/dL is associated with increased mortality risk

    Health‐related quality of life in left ventricular assist device‐supported patients

    No full text
    Aims This study aimed to evaluate the different health-related quality of life (HR-QoL) aspects in patients with both short-term and long-term duration LVAD support at pre-specified time intervals. Methods and results We performed a single-centre HR-QoL analysis of short-term and long-term LVAD-supported patients using the short version of the Kansas City Cardiomyopathy Questionnaire (KCCQ-12) and the Changes in Sexual Functioning Questionnaire along with a survey to evaluate patients social and driving routines. Data were collected at baseline and at 6 or 12 month follow-up. Included were 46 patients with a median time from LVAD implantation of 1.1 [inter-quartile range (IQR) 0.5, 2.6] years. The median KCCQ-12 summary score was 56 (IQR 29, 74) with most favourable scores in the symptom frequency domain [75 (IQR 50, 92)] and worse scores in the physical limitation [42 (IQR 25, 75)] and QoL [44 (IQR 25, 75)] domains. No significant changes were apparent during study follow-up [KCCQ-12 summary score 56 (IQR 35, 80)], and no significant correlation between the KCCQ-12 summary score and ventricular assist device-support duration was detected (r = -0.036, P = 0.812). Sexual dysfunction was noted across all domains with a cumulative score of 31 (IQR 22, 42). Seventy-six per cent of patients resumed driving after LVAD implantation, and 43% of patients reported they socialize with family and friends more frequently since surgery. Conclusions Short-term and long-term LVAD-supported patients had impaired HR-QoL and sexual function at baseline and at follow-up yet reported an improvement in social interactions and independency. A broader spectrum of patients reported HR-QoL measures should be integrated into the pre-LVAD implantation assessment and preparation
    corecore