Enlarged right ventricular size at 11 years' follow-up after closure of secundum-type atrial septal defect in children
Item does not contain fulltextBACKGROUND: The fate of right ventricular dimensions after surgical closure of secundum-type atrial septal defects remains unclear. The objectives of this study were to assess ventricular dimensions, exercise capability, and arrhythmias of patients operated for secundum-type atrial septal defect and compare the results with those in healthy references. METHODS: A total of 78 consecutive patients underwent surgical closure for a secundum-type atrial septal defect between 1990 and 1995. In all, 42 patients were included and underwent a cross-sectional evaluation including echocardiography, magnetic resonance imaging, exercise testing, and 24-hour ambulatory electrocardiography. Patients were matched with healthy controls for gender, body surface area, and age. RESULTS: The mean age at surgery was 4.6 plus or minus 2.8 years, and the mean age at follow-up was 16 plus or minus 3 years. There were no residual intracardiac lesions. The mean right ventricular endsystolic volume was significantly larger in patients (142 +/- 26 millilitres) than in references (137 +/- 28 millilitres; p = 0.04). In 25% of the patients, right ventricular end-systolic volume was larger than the 95th percentile for references. No relevant arrhythmias were detected. Exercise testing did not reveal differences with healthy references: maximal power (169 +/- 43 Watt patients versus 172 +/- 53 controls; p = 0.8), maximal oxygen uptake (38 +/- 8 versus 41 +/- 13 millilitres per minute per kilogram; p = 0.1). COMMENT: After surgical closure of secundum-type atrial septal defect, right ventricular end-systolic volume is increased. These findings have no impact on rhythm status or exercise capacity at this stage of follow-up, but may have implications for the timing of surgery or the technique of closure if confirmed in longer follow-up
Clinical condition at mid-to-late follow-up after transatrial–transpulmonary repair of tetralogy of Fallot
ObjectivesTo assess the clinical condition at mid-to-late follow-up in tetralogy of Fallot corrected by a transatrial–transpulmonary approach at a young age and to identify risk factors associated with right ventricular dilation/dysfunction and with decreased exercise tolerance.MethodsPatients with tetralogy of Fallot underwent cardiac magnetic resonance imaging, maximal bicycle ergometry, electrocardiography, Holter monitoring, and spirometry. Multivariate linear regression analyses were used to determine independent predictors for selected clinical parameters.ResultsFifty-nine patients (mean ± SD), age at repair 0.9 ± 0.5 years, interval since repair 14 ± 5 years, were included. The median pulmonary regurgitant fraction was 32% (0%-57%). Compared with published data on healthy controls, Fallot patients had significantly larger right ventricular end-diastolic and end-systolic volumes and smaller right ventricular and left ventricular ejection fractions. Maximum oxygen consumption was 97% ± 17% and maximum workload 89% ± 13% of predicted. Median QRS duration was 110 ms (82–161 ms). No important ventricular arrhythmias were found. Compared with patients without a transannular patch, patients with a patch had more pulmonary regurgitation, a larger right ventricle, worse right ventricular and left ventricular ejection fractions, but comparable exercise capacity. Multivariate regression analysis identified the following independent determinants for larger right ventricular volumes: longer interval since repair, longer QRS duration, and higher pulmonary regurgitation percentage. The following were independent determinants for smaller right ventricular ejection fraction: abnormal right ventricular outflow tract wall motion, longer interval since repair, and longer QRS duration. For smaller maximum oxygen consumption, the independent determinants were smaller right ventricular ejection fraction and longer QRS duration.ConclusionsAt mid-to-late follow-up, clinical condition in tetralogy of Fallot corrected according to contemporary surgical approaches appears well preserved. However, even these patients show right ventricular dilation and dysfunction associated with impaired functional capacity. Abnormalities relate to right ventricular outflow tract motion abnormalities, longer interval since repair, longer QRS duration, and more severe pulmonary regurgitation
Clinical outcome 5 to 18 years after the Fontan operation performed on children younger than 5 years.
Item does not contain fulltextOBJECTIVE: This study assessed clinical condition at midterm follow-up after total cavopulmonary connection for a functionally univentricular heart performed on children younger than 5 years. METHODS: Thirty-four Fontan patients (median age 10.4 years, range 6.8-20.7 years, 22 boys, median follow-up 7.8 years, 5.0-17.8 years) underwent electrocardiography, Holter monitoring, bicycle exercise testing, cardiac magnetic resonance imaging, and N-terminal prohormone brain natriuretic peptide (NT-pro-BNP) analysis. RESULTS: Twenty-three patients (68%) were in sinus rhythm. Holter monitoring demonstrated normal mean heart rate, low maximal heart rate, and no clinically significant arrhythmias or sinus node dysfunction. With maximal bicycle ergometry (n = 19), maximum workload (60% of normal), maximum heart rate (90% of normal), and maximal oxygen uptake (69% of normal) were all significantly lower in the Fontan group than in a control group (P < .001). Variables of submaximal exercise indicated less efficient oxygen uptake during exercise in all Fontan patients. Ejection fraction was lower than in control subjects (59% +/- 13% vs 69% +/- 5%, P < .001). Mean end-diastolic and end-systolic volumes and ventricular mass were higher than in control subjects (P < .001). Mean NT-pro-BNP levels were increased relative to reference values, but only 8 patients had levels above the upper reference limit. CONCLUSION: At midterm follow-up, Fontan patients were in acceptable clinical condition, with preserved global ventricular function, moderately decreased exercise capacity, and NT-pro-BNP levels within reference range. Systemic ventricular mass was elevated, however, suggesting contractility-afterload mismatch. Long-term consequences for ventricular function merit further investigation