77 research outputs found
Recommended from our members
Test Results for HINS Focusing Solenoids at Fermilab
A focusing lens R&D program is close to completion and industrial production of magnets has begun. Two types of magnets are being built for use in the room temperature RF section at the front end of a superconducting H-minus linac of a High Intensity Neutrino Source. All of the magnets are designed as a solenoid with bucking coils to cancel the field in the vicinity of adjacent RF cavities, and one type incorporates steering dipole corrector coils. We present a summary of the predicted and measured quench and magnetic properties for both R&D and production device samples that have been tested at Fermilab
Recommended from our members
HINS Superconducting Lens and Cryostat Performance
Fermi National Accelerator Laboratory is involved in the development of a 60 MeV superconducting linac. This linac is part of the High Intensity Neutrino Source (HINS) R&D Program. The initial beam acceleration in the front end section of the linac is achieved using room temperature spoke cavities, each of which is combined with a superconducting focusing solenoid. These solenoid magnets are cooled with liquid helium at 4.5K, operate at 250 A and have a maximum magnetic field strength of 7.5 T. A prototype solenoid cryostat was built and tested at the Fermilab Magnet Test Facility. This paper discusses the test results of the prototype and compares the measured and estimated performance of the cryostat. We also present the methods and results for measuring and fiducializing the axis of the solenoid lens
Recommended from our members
HTS wire irradiation test with 8 GeV protons
The radiation level at High Energy Particle Accelerators (HEPA) is relatively high. Any active component which should be close to the accelerator has to be radiation hard. Since High Temperature Superconductors (HTS) have a great potential to be used in HEPAs (e.g., in superconducting magnets, current leads, RF cavities), it is important to understand the radiation hardness of these materials. A radiation test of HTS wire (Bi-2223) was performed at Fermilab. The HTS sample was irradiated with 8 GeV protons and the relative I{sub c} was measured during the irradiation. The total radiation dose was 10 Mrad, and no I{sub c} degradation was observed
Recommended from our members
Test Results of the AC Field Measurements of Fermilab Booster Corrector Magnets
Multi-element corrector magnets are being produced at Fermilab that enable correction of orbits and tunes through the entire cycle of the Booster, not just at injection. The corrector package includes six different corrector elements--normal and skew orientations of dipole, quadrupole, and sextupole--each independently powered. The magnets have been tested during typical AC ramping cycles at 15Hz using a fixed coil system to measure the dynamic field strength and field quality. The fixed coil is comprised of an array of inductive pick-up coils around the perimeter of a cylinder which are sampled simultaneously at 100 kHz with 24-bit ADC's. The performance of the measurement system and a summary of the field results are presented and discussed
Recommended from our members
Results on Fermilab main injector dipole measurements
Measurements of the Productions run of Fermilab Main Injector Dipole magnets is underway. Redundant strength measurements provide a set of data which one can fit to mechanical and magnetic properties of the assembly. Plots of the field contribution from the steel supplement the usual plots of transfer function (B/I) vs. I in providing insight into the measured results
Design and fabrication of a multi-element corrector magnet for the Fermilab Booster synchrotron
To better control the beam position, tune, and chromaticity in the Fermilab Booster synchrotron, a new package of six corrector elements has been designed, incorporating both normal and skew orientations of dipole, quadrupole, and sextupole magnets. The devices are under construction and installation at 48 locations is planned. The density of elements and the rapid slew rate have posed special challenges. The magnet construction is presented along with DC measurements of the magnetic field
Recommended from our members
HINS Linac front end focusing system R&D
This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process
Field quality of quadrupole R&D models for the LHC IR
Superconducting quadrupole magnets operating in superfluid helium at 1.9 K, with 70 mm bore and nominal field gradient of 205 T/m at collision optics, are being developed by the US LHC Accelerator Project for the Interaction Regions of the Large Hadron Collider (LHC). A magnet model program to validate and optimize the design is underway. This paper reports results of field quality measurements of four model magnets. (3 refs)
- …