10 research outputs found

    Technical and clinical success after endovascular therapy for chronic type B aortic dissections

    Get PDF
    ObjectiveTo analyze early technical success and late clinical success after endovascular entry sealing for chronic type B dissection with special emphasis on reintervention, false lumen thrombosis, and aortic remodeling.MethodsRetrospective analysis of a prospective database. From September 1999 to January 2011, 19 patients with chronic type B dissections were treated by endovascular entry sealing. Median age was 60 years. Median time between onset of acute dissection and surgical intervention was 36 (1 to 60) months. Median follow-up was 13 months (1 to 124).ResultsThe endografts used were: Medtronic Captivia (5), Medtronic Valiant (5), Gore TAG (6), Gore C-TAG (2), and Cook Zenith (1). In four patients, revascularization of the left subclavian artery was performed prior to entry sealing. Primary technical success rate (entry sealing, absence of type I leak) was 18/19 (94.7%). In-hospital mortality was 0%. Spinal cord injury with persistent paraplegia occurred in 1/19 (5.2%) patients. After a maximal follow-up of 124 months, reinterventions in 9/19 (47.3%) were necessary: distal/proximal extension of stent graft (8), replacement of the aortic arch due to retrograde dissection (1), and open infrarenal aneurysm repair (1). During follow-up, none of the patients died due to stent-related complications.ConclusionEndovascular treatment (EVT) in chronic type B dissections has a high technical success rate and low mortality/morbidity. However reintervention rates are not negligible which might reduce the clinical success of EVT. Future investigations should aim at identifying patients who benefit from EVT at better defining the timing of EVT and at determining if entry sealing alone is sufficient

    Results from a first-in-human trial of a novel vascular sealant

    Get PDF
    Background: Suture hole bleeding from synthetic grafts presents a hemostatic challenge. The designs of many vascular sealants are not optimal (non-adherence to wet surfaces, excessive swelling, inflexible). PreveLeak (TM) (formerly ArterX (R)) is a polyaldehyde bovine serum albumin-based sealant whose efficacy, safety, and performance were evaluated in this first-in-human study. Materials and methods: A prospective, single-arm, multicenter study was performed in patients undergoing open vascular reconstructions with prosthetic grafts. Sealant was applied to the suture line after completion of the anastomosis. The primary endpoint was the incidence of immediate sealing (without clinically significant bleeding) upon clamp release. Secondary endpoints were time to sealing, safety, and assessment of product performance. Results: Fifty-six anastomoses were performed in 32 patients. Grafts were Dacron (66% of sites), polytetrafluoroethylene (PTFE; 32%), or both Dacron and PTFE (2%). The femoral artery was the most common site of anastomosis (41% of sites). Immediate sealing after clamp release was achieved at all anastomoses (100%); 93% had no bleeding and 7% had oozing. No rebleeding occurred during 10 min of observation. The three most common adverse events were graft or bypass occlusion (n = 5 patients), infection (n = 4), and seroma (n = 3); none were device related. The sealant was considered easy to apply, quickly forming a soft gel, and adhering to tissue and grafts. Conclusion: PreveLeak effectively sealed anastomotic suture lines during vascular reconstruction procedures and was considered easy to use. Adverse events were consistent with those commonly observed in patients undergoing surgical procedures. These results provided the support for conducting a larger controlled clinical trial

    Valiant Thoracic Stent-Graft Deployed With the New Captivia Delivery System: Procedural and 30-Day Results of the Valiant Captivia Registry

    No full text
    Purpose: To evaluate procedural and 30-day outcomes of thoracic endovascular aortic repair (TEVAR) employing the Valiant Thoracic Stent Graft with the Captivia Delivery System

    Phospholipids reduce gastric cancer cell adhesion to extracellular matrix <it>in vitro</it>

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Nidation of floating tumour cells initiates peritoneal carcinosis and limits prognosis of gastro-intestinal tumours. Adhesion of tumour cells to extracellular matrix components is a pivotal step in developing peritoneal dissemination of intraabdominal malignancies. Since phospholipids efficaciously prevented peritoneal adhesion formation in numerous animal studies we investigated their capacity to reduce adhesions of gastric cancer cells to extracellular matrix components (ECM).</p> <p>Methods</p> <p>Human gastric cancer cells (NUGC-4, Japanese Cancer Research Resources Bank, Tokyo, Japan) were used in this study. Microtiter plates were coated with collagen IV (coll), laminin (ln) and fibronectin (fn). Non-specific protein binding of the coated wells was blocked by adding 1% (w/v) BSA (4°C, 12 h) and rinsing the wells with Hepes buffer. 50.000 tumour cells in 100 μl medium were seeded into each well. Beside the controls, phospholipids were added in concentrations of 0.05, 0.1, 0.5, 0.75 and 1.0/100 μl medium. After an incubation interval of 30 min, attached cells were fixed and stained with 0.1% (w/v) crystal violet. The dye was resuspended with 50 μl of 0.2% (v/v) Triton X-100 per well and colour yields were then measured by an ELISA reader at 590 nm. Optical density (OD) showed a linear relationship to the amount of cells and was corrected for dying of BSA/polystyrene without cells.</p> <p>Results</p> <p>The attachment of gastric cancer cells to collagen IV, laminin, and fibronectin could be significantly reduced up to 53% by phospholipid concentrations of 0.5 mg/100 μl and higher.</p> <p>Conclusion</p> <p>These results, within the scope of additional experimental studies on mice and rats which showed a significant reduction of peritoneal carcinosis, demonstrated the capacity of phospholipids in controlling abdominal nidation of tumour cells to ECM components. Lipid emulsions may be a beneficial adjunct in surgery of gastrointestinal malignancies.</p

    Kant-Bibliographie 2004

    No full text
    corecore