8 research outputs found

    Effect of ventilator-associated tracheobronchitis on outcome in patients without chronic respiratory failure: a case–control study

    Get PDF
    INTRODUCTION: Our objective was to determine the effect of ventilator-associated tracheobronchitis (VAT) on outcome in patients without chronic respiratory failure. METHODS: This was a retrospective observational matched study, conducted in a 30-bed intensive care unit (ICU). All immunocompetent, nontrauma, ventilated patients without chronic respiratory failure admitted over a 6.5-year period were included. Data were collected prospectively. Patients with nosocomial pneumonia, either before or after VAT, were excluded. Only first episodes of VAT occurring more than 48 hours after initiation of mechanical ventilation were studied. Six criteria were used to match cases with controls, including duration of mechanical ventilation before VAT. Cases were compared with controls using McNemar's test and Wilcoxon signed-rank test for qualitative and quantitative variables, respectively. Variables associated with a duration of mechanical ventilation longer than median were identified using univariate and multivariate analyses. RESULTS: Using the six criteria, it was possible to match 55 (87%) of the VAT patients (cases) with non-VAT patients (controls). Pseudomonas aeruginosa was the most frequently isolated bacteria (34%). Although mortality rates were similar between cases and controls (29% versus 36%; P = 0.29), the median duration of mechanical ventilation (17 days [range 3–95 days] versus 8 [3–61 days]; P < 0.001) and ICU stay (24 days [range 5–95 days] versus 12 [4–74] days; P < 0.001) were longer in cases than in controls. Renal failure (odds ratio [OR] = 4.9, 95% confidence interval [CI] = 1.6–14.6; P = 0.004), tracheostomy (OR = 4, 95% CI = 1.1–14.5; P = 0.032), and VAT (OR = 3.5, 95% CI = 1.5–8.3; P = 0.004) were independently associated with duration of mechanical ventilation longer than median. CONCLUSION: VAT is associated with longer durations of mechanical ventilation and ICU stay in patients not suffering from chronic respiratory failure

    Tentative de suicide par injection intraveineuse de mercure. À propos d’un cas

    No full text
    Objectif : Nous rapportons le cas d’une tentative de suicide par injection intraveineuse de mercure métal. Résultats : Les emboles de mercure sont retrouvés sur les radiographies et les scanners thoraciques et abdominaux au niveau des poumons, du cœur, des reins et du foie. Le mercure est dosé par SAA et ICP-MS dans le sang, les urines et les cheveux. Discussion : Lors du suivi deux années durant, malgré des concentrations de mercure élevées dans le sang et les urines, et la persistance de dépôts mercuriels dans les tissus, aucune anomalie biologique des fonctions hépatique ou rénale ni atteinte clinique pulmonaire et neurologique ne sont détectées

    Measurement site of inferior vena cava diameter affects the accuracy with which fluid responsiveness can be predicted in spontaneously breathing patients: a post hoc analysis of two prospective cohorts

    No full text
    International audienceBackground: The collapsibility index of the inferior vena cava (cIVC) has potential for predicting fluid responsiveness in spontaneously breathing patients, but a standardized approach for measuring the inferior vena cava diameter has yet to be established.The aim was to test the accuracy of different measurement sites of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with sepsis-related circulatory failure and examine the influence of a standardized breathing manoeuvre.Results: Among the 81 patients included in the study, the median Simplified Acute Physiologic Score II was 34 (24; 42). Sepsis was of pulmonary origin in 49 patients (60%). Median volume expansion during the 24 h prior to study inclusion was 1000 mL (0; 2000). Patients were not severely ill: none were intubated, only 20% were on vasopressors, and all were apparently able to perform a standardized breathing exercise. Forty-one (51%) patients were responders to volume expansion (i.e. a ≥ 10% stroke volume index increase). The cIVC was calculated during non-standardized (cIVC-ns) and standardized breathing (cIVC-st) conditions. The accuracy with which both cIVC-ns and cIVC-st predicted fluid responsiveness differed significantly by measurement site (interaction p < 0.001 and < 0.0001, respectively). Measuring inferior vena cava diameters 4 cm caudal to the right atrium predicted fluid responsiveness with the best accuracy. At this site, a standardized breathing manoeuvre also significantly improved predictive power: areas under ROC curves [mean and (95% CI)] for cIVC-ns = 0.85 [0.78–0.94] versus cIVC-st = 0.98 [0.97–1.0], p < 0.001. When cIVC-ns is superior or equal to 33%, fluid responsiveness is predicted with a sensitivity of 66% and a specificity of 92%. When cIVC-st is superior or equal to 44%, fluid responsiveness is predicted with a sensitivity of 93% and a specificity of 98%.Conclusion: The accuracy with which cIVC measurements predict fluid responsiveness in spontaneously breathing patients depends on both the measurement site of inferior vena cava diameters and the breathing regime. Measuring inferior vena cava diameters during a standardized inhalation manoeuvre at 4 cm caudal to the right atrium seems to be the method by which to obtain cIVC measurements best-able to predict patients’ response to volume expansion

    High-Dose Dexamethasone and Oxygen Support Strategies in Intensive Care Unit Patients With Severe COVID-19 Acute Hypoxemic Respiratory Failure

    No full text
    International audienc
    corecore