4 research outputs found

    Results of the EURAMET.RI(II)- S7.Sm-151 supplementary comparison (EURAMET Project 1292)

    No full text
    An international comparison of the activity standardisation of the relatively long-lived gamma-ray emitter 151Sm has been recently completed. A total of six laboratories measured a solution prepared by CEA/LNHB and CEA/LANIE. Aliquots of the master solution were standardized in terms of activity per mass unit by participant laboratories using 2 different techniques. The results of the comparison can be used as the basis for establishing equivalence among the laboratories. The activity measurements of this comparison are part of the joint research project “Metrology for Radioactive Waste Management” of the European Metrology Research Programme (EMRP). One aim of this project is a new determination of the 151Sm half-life.JRC.D.4-Standards for Nuclear Safety, Security and Safeguard

    Determination of the 151Sm half-life

    No full text
    New measurements have been undertaken to determine the half-life of 151Sm. A pure 151Sm solution was obtained after chemical separation from a samarium solution resulting from the dissolution of an irradiated samarium sample. The concentration of 151Sm in the solution was measured by mass spectrometry, combined with the isotope dilution technique. The activity of the solution was measured by liquid scintillation counting by six European laboratories as part of an international comparison. These combined results lead to a half-life of T1/2 = 94.6(6) a.JRC.D.4-Standards for Nuclear Safety, Security and Safeguard

    Results of an international comparison of activity measurements of 68 Ge

    No full text
    Proceedings of the 21st International Conference on Radionuclide Metrology and its Applications (ICRM), May 15-19, 2017, Buenos Aires, Argentina. Organizer: Argentinian National Atomic Energy CommissionInternational audienceAn international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)β-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11) kBq g−1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6 mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence
    corecore