1,219 research outputs found

    A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources

    Get PDF
    Phase contrast imaging (PCI) solves the basic limitation of x-ray imaging, i.e., poor image contrast resulting from small absorption differences. Up to now, it has been mostly limited to synchrotron radiation facilities, due to the stringent requirements on the x-ray source and detectors, and only one technique was shown to provide PCI images with conventional sources but with limits in practical implementation. The authors propose a different approach, based on coded apertures, which provides high PCI signals with conventional sources and detectors and imposes practically no applicability limits. They expect this method to cast the basis of a widespread diffusion of PCI. (C) 2007 American Institute of Physics

    A multi-layer edge-on single photon counting silicon microstrip detector for innovative techniques in diagnostic radiology

    Get PDF
    A three-layer detector prototype, obtained by stacking three edge-on single photon counting silicon microstrip detectors, has been developed and widely tested. This was done in the framework of the Synchrotron Radiation for Medical Physics/Frontier Radiology (SYRMEP/FRONTRAD) collaboration activities, whose aim is to improve the quality of mammographic examinations operating both on the source and on the detector side. The active surface of the device has been fully characterized making use of an edge-scanning technique and of a well-collimated laminar synchrotron radiation beam. The obtained data (interlayer distances, channel correspondence, etc.) have then been used to combine information coming from each detector layer, without causing any loss in spatial and contrast resolution of the device. Contrast and spatial resolution have also been separately evaluated for each detector layer. Moreover, imaging techniques (phase contrast, refraction, and scatter imaging), resulting in an increased visibility of low absorbing details, have been implemented, and their effectiveness has been tested on a biological sample. Finally, the possibility of simultaneously acquiring different kind of images with the different detector layers is discussed. This would result in maximizing the information extracted from the sample, while at the same time the high absorption efficiency of the detector device would allow a low dose delivery

    Evaluation of a compact multi-contrast and multi-resolution X-ray phase contrast edge illumination system for small animal imaging

    Get PDF
    PURPOSE: In this work the performance of a compact multi-resolution and multi-contrast X-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS: The presented edge illumination system is based on a compact microfocus tungsten X-ray source combined with a at panel detector. The source has a maximum output of 10 W when the minimum spot size of about 15 µm is used. The system has an overall length of 70 cm. A new double sample mask design, obtained by arranging both skipped and non-skipped configurations on the same structure, provides dual resolution capability. To test the system, we carried out CT scans of a plastic phantom with different source settings using both single-image and multi-image acquisition schemes at different spatial resolutions. In addition, CT scans of an ex-vivo mouse specimen were acquired at the best identified working conditions to demonstrate the application of the presented system to small animal imaging. RESULTS: We found this system delivers good image quality, allowing for an efficient material separation and improving detail visibility in small animals thanks to the higher signal-to-noise ratio (SNR) of phase contrast with respect to conventional attenuation contrast. The system offers high versatility in terms of spatial resolution thanks to the double sample mask design integrated into a single scanner. The availability of both multi and single image acquisition schemes coupled with their dedicated retrieval algorithms, allows different working modes which can be selected based on user preference. Multi-image acquisition provides quantitative separation of the real and imaginary part of the refractive index, however it requires a long scanning time. On the other hand, the single image approach delivers the best material separation and image quality at all the investigated source settings with a shorter scanning time but at the cost of quantitativeness. Finally, we also observed that the single image approach combined with a high-power X-ray source may result in a fast acquisition protocol compatible with in-vivo imaging

    Laboratory implementation of edge illumination X-ray phase-contrast imaging with energy-resolved detectors

    Get PDF
    Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has potential for applications in different fields of research, including materials science, non-destructive industrial testing, small-animal imaging, and medical imaging. One of its main advantages is the compatibility with laboratory equipment, in particular with conventional non-microfocal sources, which makes its exploitation in normal research laboratories possible. In this work, we demonstrate that the signal in laboratory implementations of EI can be correctly described with the use of the simplified geometrical optics. Besides enabling the derivation of simple expressions for the sensitivity and spatial resolution of a given EI setup, this model also highlights the EI’s achromaticity. With the aim of improving image quality, as well as to take advantage of the fact that all energies in the spectrum contribute to the image contrast, we carried out EI acquisitions using a photon-counting energy-resolved detector. The obtained results demonstrate that this approach has great potential for future laboratory implementations of EI. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Patterns of cervical and masticatory impairment in subgroups of people with temporomandibular disorders–an explorative approach based on factor analysis

    Get PDF
    Objectives: To identify clinical patterns of impairment affecting the cervical spine and masticatory systems in different subcategories of temporomandibular disorder (TMD) by an explorative data-driven approach. Methods: For this observational study, 144 subjects were subdivided according to Research Diagnostic Criteria for TMDs into: Healthy controls, temporomandibular joint (TMJ) signs without symptoms, TMJ affected, temporomandibular muscles affected, or TMJ and muscles affected. Factor analysis and linear regression were applied to cervical spine and masticatory data to identify and characterize clinical patterns in subgroups. Results: Factor analysis identified five clinical dimensions, which explained 59% of all variance: Mechanosensitivity, cervical movement, cervical and masticatory dysfunction, jaw movement, and upper cervical movement. Regression analysis identified different clinical dimensions in each TMD subgroup. Conclusion: Distinct clinical patterns of cervical spine and masticatory function were found among subgroups of TMD, which has clinical implications for therapeutic management

    Methotrexate and Cyclosporine Treatments Modify the Activities of Dipeptidyl Peptidase IV and Prolyl Oligopeptidase in Murine Macrophages

    Get PDF
    Analysis of the effects of cyclosporine A (25–28 mgkg−1) and/or methotrexate (0.1 mgkg−1) treatments on dipeptidyl peptidase IV (DPPIV) and prolyl oligopeptidase (POP) activities and on algesic response in two distinct status of murine macrophages (Mφs) was undertaken. In resident Mφs, DPPIV and POP were affected by neither individual nor combined treatments. In thioglycolate-elicited Mφs, methotrexate increased DPPIV (99–110%) and POP (60%), while cyclosporine inhibited POP (21%). Combined treatment with both drugs promoted a rise (51–84%) of both enzyme activities. Only cyclosporine decreased (42%) the tolerance to algesic stimulus. Methotrexate was revealed to exert prevalent action over that of cyclosporine on proinflammatory Mφ POP. The opposite effects of methotrexate and cyclosporine on POP activity might influence the availability of the nociceptive mediators bradykinin and substance P in proinflammatory Mφs. The exacerbated response to thermally induced algesia observed in cyclosporine-treated animals could be related to upregulation of those mediators

    Edge-illumination x-ray phase contrast imaging with Pt-based metallic glass masks

    Get PDF
    Edge-illumination x-ray phase contrast imaging (EI XPCI) is a non-interferometric phase-sensitive method where two absorption masks are employed. These masks are fabricated through a photolithography process followed by electroplating which is challenging in terms of yield as well as time- and cost-effectiveness. We report on the first implementation of EI XPCI with Pt-based metallic glass masks fabricated by an imprinting method. The new tested alloy exhibits good characteristics including high workability beside high x-ray attenuation. The fabrication process is easy and cheap, and can produce large-size masks for high x-ray energies within minutes. Imaging experiments show a good quality phase image, which confirms the potential of these masks to make the EI XPCI technique widely available and affordable

    Real-time evaluation of the on-board comfort of standing passenger in bus transit services

    Get PDF
    Bus on-board comfort may be intended as a multidimensional concept declined according to several attributes (e.g., vibrations, the load factor, the driving style, etc.) and represents a key factor of service quality. Thus, its measurement is crucial for public transport companies as it can support for the monitoring, evaluation and implementation of specific actions to improve their services. The objective of this paper is to build a numerical scale for real-time measurement of bus on-board comfort. This is pursued integrating subjective measurements of the driving style provided by the passengers with objective ones of longitudinal and transversal accelerations data collected by Intelligent Transportation System tools. The results are very useful because they represent a contribution to establish a comfort scale in a real operational environment, as a tool to regulate the driver's behavior: each driver is in the position of real-time monitoring the quality of a bus ride regarding on-board comfort level

    Accuracy of clinical staging for T2N0 oesophageal cancer: systematic review and meta-analysis

    Get PDF
    Oesophageal cancer is the sixth commonest cause of overall cancer mortality. Clinical staging utilizes multiple imaging modalities to guide treatment and prognostication. T2N0 oesophageal cancer is a treatment threshold for neoadjuvant therapy. Data on accuracy of current clinical staging tests for this disease subgroup are conflicting. We performed a meta-analysis of all primary studies comparing clinical staging accuracy using multiple imaging modalities (index test) to histopathological staging following oesophagectomy (reference standard) in T2N0 oesophageal cancer. Patients that underwent neoadjuvant therapy were excluded. Electronic databases (MEDLINE, Embase, Cochrane Library) were searched up to September 2019. The primary outcome was diagnostic accuracy of combined T&N clinical staging. Publication date, first recruitment date, number of centers, sample size and geographical location main histological subtype were evaluated as potential sources of heterogeneity. The search strategy identified 1,199 studies. Twenty studies containing 5,213 patients met the inclusion criteria. Combined T&N staging accuracy was 19% (95% CI, 15–24); T staging accuracy was 29% (95% CI, 24–35); percentage of patients with T downstaging was 41% (95% CI, 33–50); percentage of patients with T upstaging was 28% (95% CI, 24–32) and percentage of patients with N upstaging was 34% (95% CI, 30–39). Significant sources of heterogeneity included the number of centers, sample size and study region. T2N0 oesophageal cancer staging remains inaccurate. A significant proportion of patients were downstaged (could have received endotherapy) or upstaged (should have received neoadjuvant chemotherapy). These findings were largely unchanged over the past two decades highlighting an urgent need for more accurate staging tests for this subgroup of patients
    corecore