17 research outputs found

    Short- and mid-term outcome of transcatheter aortic valve implantation in patients with advanced age

    Get PDF
    Background: In patients treated with transcatheter aortic valve implantation (TAVI), age is recognized as one of the most important risk factors. The aim of our study was to evaluate whether early and mid-term results of TAVI were worse in patients over 85 year old compared with the younger population. Methods: From September 2010 to November 2015, 162 consecutive patients (mean age 78.4 ± 7.1 years, 47.5% females) underwent TAVI in our Institution. Patients were divided into two groups: 1) elderly (≥ 85 year old) and 2) younger patients (< 85 year old). Primary clinical study endpoints were the fol­lowing: death, myocardial infarction, stroke, major and minor access site, and bleeding complications. The secondary endpoints included: pacemaker implantation rate, paravalvular leakage, acute kidney injury, and duration of hospitalization. Results: Twenty-six patients were 85 or older (mean 87.5 ± 2.1). In the remaining 136 (84%), the average age was 76.7 ± 6.4. Baseline clinical profiles were similar in both groups, though history of pre­vious cardiac surgery (p = 0.0047) and chronic obstructive pulmonary disease (p = 0.0099) were more common in the younger group, and glomerular filtration rate was lower in the older group (p = 0.045). Major, life threatening and minor bleeding complications, as well as vascular access site complications did not differ between the two groups. Rates of myocardial infarction and stroke were comparably low in both groups. Similar results were also found in the incidence of secondary endpoints. In-hospital mortality and 1-year mortality did not differ between groups. Conclusions: TAVI in patients aged 85 and older is still a relatively safe procedure and age itself should not be a discriminatory factor in TAVI qualification. (Cardiol J 2017; 24, 4: 358–363

    Femoral artery anatomy-tailored approach in transcatheter aortic valve implantation

    No full text
    Introduction : The best techniques for reduction of femoral access site complications after transcatheter aortic valve implantation (TAVI) remain the object of research. Aim : We report on a single center’s experience with TAVI performed via the femoral access site. Material and methods : Between September 2010 and September 2015, 152 consecutive patients underwent TAVI in our department. Of them, 101 patients with CoreValve implantation from the femoral access site were included in the analysis. The femoral artery anatomy-tailored approach was introduced in 2013 in order to reduce the rate of access-site complications. Patients were assigned to percutaneous puncture or surgical cut-down depending on the femoral artery anatomy assessed in computed tomography. The study patients were divided into two subgroups: group A – patients treated before January 2013, before introduction of the tailored approach program (n = 34); and group B – patients treated between January 2013 and April 2015 (n = 67). Results : The access site complication rate significantly decreased from 35.3% in group A (n = 12) to 7.5% in group B (n = 5) (p = 0.0012). Both minor and major access site complications were more frequent in group A (p = 0.04 and 0.016, respectively). In-hospital mortality was 8.8% (n = 3) in group A and 1.5% (n = 1) in group B (p = 0.1). Conclusions : The femoral artery anatomy-tailored approach significantly reduces the incidence of access site complications in TAVI patients

    Patient Safety during ECMO Transportation: Single Center Experience and Literature Review

    No full text
    Background. Extracorporeal membrane oxygenation (ECMO) has been proven to support in lifesaving rescue therapy. The best outcomes can be achieved in high-volume ECMO centers with dedicated emergency transport teams. Aim. The aim of this study was to analyze the safety of ECMO support during medical transfer on the basis of our experience developed on innovation cooperation and review of literature. Methods. A retrospective analysis of our experience of all ECMO-supported patients transferred from regional hospital of the referential ECMO center between 2015 and 2020 was carried out. Special attention was paid to transportation-related mortality and morbidity. Moreover, a systematic review of the Medline, Embase, Cochrane, and Google Scholar databases was performed. It included the original papers published before the end of 2019. Results. Twelve (5 women and 7 men) critically ill ECMO-supported patients with the median age of 33 years (2–63 years) were transferred to our ECMO center. In 92% (n = 11) of the cases venovenous and in 1 case, venoarterial supports were applied. The median transfer length was 45 km (5–200). There was no mortality during transfer and no serious adverse events occurred. Of note, the first ECMO-supported transfer had been proceeded by high-fidelity simulations. For our systematic review, 68 articles were found and 22 of them satisfied the search criteria. A total number of 2647 transfers were reported, mainly primary (90%) and as ground transportations (91.6%). A rate of adverse events ranged from 1% through 20% but notably only major complications were mentioned. The 4 deaths occurred during transport (mortality 0.15%). Conclusions. Our experiences and literature review showed that transportation for ECMO patients done by experienced staff was associated with low mortality rate but life-threatening adverse events might occur. Translational simulation is an excellent probing technique to improve transportation safety
    corecore