12 research outputs found

    Solution of the Bosonic and Algebraic Hamiltonians by using AIM

    Full text link
    We apply the notion of asymptotic iteration method (AIM) to determine eigenvalues of the bosonic Hamiltonians that include a wide class of quantum optical models. We consider solutions of the Hamiltonians, which are even polynomials of the fourth order with the respect to Boson operators. We also demonstrate applicability of the method for obtaining eigenvalues of the simple Lie algebraic structures. Eigenvalues of the multi-boson Hamiltonians have been obtained by transforming in the form of the single boson Hamiltonian in the framework of AIM

    Any l-state improved quasi-exact analytical solutions of the spatially dependent mass Klein-Gordon equation for the scalar and vector Hulthen potentials

    Full text link
    We present a new approximation scheme for the centrifugal term to obtain a quasi-exact analytical bound state solutions within the framework of the position-dependent effective mass radial Klein-Gordon equation with the scalar and vector Hulth\'{e}n potentials in any arbitrary DD dimension and orbital angular momentum quantum numbers l.l. The Nikiforov-Uvarov (NU) method is used in the calculations. The relativistic real energy levels and corresponding eigenfunctions for the bound states with different screening parameters have been given in a closed form. It is found that the solutions in the case of constant mass and in the case of s-wave (l=0l=0) are identical with the ones obtained in literature.Comment: 25 pages, 1 figur

    Performance evaluation of soft copy display systems according to AAPM TG18 protocol

    No full text
    The purpose of this study was to evaluate the display performance of the liquid crystal display monitors according to the American association of physicists in medicine task group 18 (AAPM TG18) protocol at prior and after new calibration. We measured minimum and maximum luminance, luminance ratio, luminance and contrast response, luminance angular and spatial dependency, resolution, veiling glare and chromaticity quantitatively for 33 medical displays. Display noise was evaluated only visually. The mean maximum luminance and luminance ratio were 386 and 273 cd m(-2), respectively. The mean deviation of measured luminance and contrast response from expected response associated with the digital imaging and communications in medicine (DICOM) grayscale standard display function (GSDF) were 9.76 and 2.35 % at prior calibration and 1.23 and 0.26 % after recalibration, respectively. In luminance uniformity test the mean maximum luminance deviation was 16 %. Luminance method was used in the spatial resolution test and the mean percent luminance difference was 12 % at the center. The mean glare ratio was 1 154. The average color uniformity parameter across the display area of each display device was 0.0093. Majority of the test results were in good agreement with the criteria recommended by AAPM TG18 report. Considerable improvement was observed in display luminance and contrast response with respect to expected response of DICOM GSDF after new calibration for some displays
    corecore