    Breath detection algorithms affect multiple-breath washout outcomes in pre-school and school age children.

    Get PDF
    BACKGROUND Accurate breath detection is essential for the computation of outcomes in the multiple-breath washout (MBW) technique. This is particularly important in young children, where irregular breathing is common, and the designation of inspirations and expirations can be challenging. AIM To investigate differences between a commercial and a novel breath-detection algorithm and to characterize effects on MBW outcomes in children. METHODS We replicated the signal processing and algorithms used in Spiroware software (v3.3.1, Eco Medics AG). We developed a novel breath detection algorithm (custom) and compared it to Spiroware using 2,455 nitrogen (N2) and 325 sulfur hexafluoride (SF6) trials collected in infants, children, and adolescents. RESULTS In 83% of N2 and 32% of SF6 trials, the Spiroware breath detection algorithm rejected breaths and did not use them for the calculation of MBW outcomes. Our custom breath detection algorithm determines inspirations and expirations based on flow reversal and corresponding CO2 elevations, and uses all breaths for data analysis. In trials with regular tidal breathing, there were no differences in outcomes between algorithms. However, in 10% of pre-school children tests the number of breaths detected differed by more than 10% and the commercial algorithm underestimated the lung clearance index by up to 21%. CONCLUSION Accurate breath detection is challenging in young children. As the MBW technique relies on the cumulative analysis of all washout breaths, the rejection of breaths should be limited. We provide an improved algorithm that accurately detects breaths based on both flow reversal and CO2 concentration

    Respiratory symptoms do not reflect functional impairment in early CF lung disease.

    Get PDF
    BACKGROUND Lung disease can develop within the first year of life in infants with cystic fibrosis (CF). However, the frequency and severity of respiratory symptoms in infancy are not known. METHODS We assessed respiratory symptoms in 50 infants with CF and 50 healthy matched controls from two prospective birth cohort studies. Respiratory symptoms and respiratory rate were documented by standardized weekly interviews throughout the first year. Infants performed multiple breath washout in the first weeks of life. RESULTS We analyzed 4552 data points (2217 in CF). Respiratory symptoms (either mild or severe) were not more frequent in infants with CF (OR:1.1;95% CI:[0.76, 1.59]; p=0.6). Higher lung clearance index and higher respiratory rate in infants with CF were not associated with respiratory symptoms. CONCLUSIONS We found no difference in respiratory symptoms between healthy and CF infants. These data indicate that early CF lung disease may not be captured by clinical presentation alone

    CXCR5<sup>+</sup> follicular cytotoxic T cells control viral infection in B cell follicles

    Get PDF
    During unresolved infections, some viruses escape immunological control and establish a persistant reservoir in certain cell types, such as human immunodeficiency virus (HIV), which persists in follicular helper T cells (TFH cells), and Epstein-Barr virus (EBV), which persists in B cells. Here we identified a specialized group of cytotoxic T cells (TC cells) that expressed the chemokine receptor CXCR5, selectively entered B cell follicles and eradicated infected TFH cells and B cells. The differentiation of these cells, which we have called 'follicular cytotoxic T cells' (TFC cells), required the transcription factors Bcl6, E2A and TCF-1 but was inhibited by the transcriptional regulators Blimp1, Id2 and Id3. Blimp1 and E2A directly regulated Cxcr5 expression and, together with Bcl6 and TCF-1, formed a transcriptional circuit that guided TFC cell development. The identification of TFC cells has far-reaching implications for the development of strategies to control infections that target B cells and TFH cells and to treat B cell–derived malignancies

    Pulmonary inflammatory response and immunomodulation to multiple trauma and hemorrhagic shock in pigs

    No full text
    Background: Patients suffering from severe trauma experience substantial immunological stress. Lung injury is a known risk factor for the development of posttraumatic complications, but information on the long-term course of the pulmonary inflammatory response and treatment with mild hypothermia are scarce. Aim: To investigate the pulmonary inflammatory response to multiple trauma and hemorrhagic shock in a porcine model of combined trauma and to assess the immunomodulatory properties of mild hypothermia. Methods: Following induction of trauma (blunt chest trauma, liver laceration, tibia fracture), two degrees of hemorrhagic shock (45 and 50%) over 90 (n = 30) and 120 min. (n = 20) were induced. Animals were randomized to hypothermia (33°C) or normothermia (38°C). We evaluated bronchoalveolar lavage (BAL) fluid and tissue levels of cytokines and investigated changes in microRNA- and gene-expression as well as tissue apoptosis. Results: We observed a significant induction of Interleukin (IL) 1β, IL-6, IL-8, and Cyclooxygenase-2 mRNA in lung tissue. Likewise, an increased IL-6 protein concentration could be detected in BAL-fluid, with a slight decrease of IL-6 protein in animals treated with hypothermia. Lower IL-10 protein levels in normothermia and higher IL-10 protein concentrations in hypothermia accompanied this trend. Tissue apoptosis increased after trauma. However, intervention with hypothermia did not result in a meaningful reduction of pro-inflammatory biomarkers or tissue apoptosis. Conclusion: We observed signs of a time-dependent pulmonary inflammation and apoptosis at the site of severe trauma, and to a lower extent in the trauma-distant lung. Intervention with mild hypothermia had no considerable effect during 48 hours following trauma

    Shedding light into the black box of infant multiple-breath washout.

    No full text
    BACKGROUND Multiple-breath inert gas washout (MBW) is a sensitive technique to assess lung volumes and ventilation inhomogeneity in infancy. Poor agreement amongst commercially available setups and a lack of transparency in the underlying algorithms for the computation of infant MBW outcomes currently limit the widespread application of MBW as a surveillance tool in early lung disease. METHODS We determined all computational steps in signal processing and the calculation of MBW outcomes in the current infant WBreath/Exhalyzer D setup (Exhalyzer D device, Eco Medics AG; WBreath software version 3.28.0, ndd Medizintechnik AG; Switzerland). We developed a revised WBreath version based on current consensus guidelines and compared outcomes between the current (3.28.0) and revised (3.52.3) WBreath version. We analyzed 60 visits from 40 infants with cystic fibrosis (CF) and 20 healthy controls at 6 weeks and 1 year of age. RESULTS Investigation into the algorithms in WBreath 3.28.0 revealed discrepancies from current consensus guidelines, which resulted in a potential overestimation of functional residual capacity (FRC) and underestimation of lung clearance index (LCI). We developed a revised WBreath version (3.52.3), which overall resulted in 6.7% lower FRC (mean (SD) -1.78 (0.99) mL/kg) and 14.1% higher LCI (1.11 (0.57) TO) than WBreath version 3.28.0. CONCLUSION Comprehensive investigation into the signal processing and algorithms used for analysis of MBW measurements improves the transparency and robustness of infant MBW data. The revised software version calculates outcomes according to consensus guidelines. Future work is needed to validate and compare outcomes between infant MBW setups

    Correction of measurement error in a commercial multiple-breath washout device

    No full text
    Rationale Nitrogen multiple-breath washout (N2MBW) is an established technique to assess functional residual capacity (FRC) and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes. Objectives We investigated the accuracy of oxygen and carbon dioxide measurements used for the indirect calculation of nitrogen concentration in a commercial MBW device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on FRC and lung clearance index (LCI). Methods High precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on FRC and LCI in a dataset of healthy children and children with cystic fibrosis using custom analysis software. Results We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration, and consequently FRC and LCI outcomes. Breath-by-breath correction of this error reduced mean (SD) FRC by 8.9 (2.2)% and LCI by 11.9 (4.0)%. It also resulted in almost complete disappearance of the tissue nitrogen signal at the end of measurements. Conclusions Inadequate correction for cross sensitivity between the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of FRC and LCI. Correction of this error is possible and could be applied by re-analysing the measurements breath-by-breath in an updated software version

    Correction of sensor crosstalk error in Exhalyzer D multiple-breath washout device significantly impacts outcomes in children with cystic fibrosis.

    No full text
    RATIONALE Nitrogen multiple-breath washout is an established technique to assess functional residual capacity and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes. OBJECTIVES We investigated the accuracy of oxygen and carbon dioxide gas sensor measurements used for the indirect calculation of nitrogen concentration in a commercial multiple-breath washout device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on functional residual capacity and lung clearance index. METHODS High precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on multiple-breath washout outcomes in a dataset of healthy children and children with cystic fibrosis using custom analysis software. RESULTS We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration, and consequently multiple-breath washout outcomes. Breath-by-breath correction of this error reduced the mean (SD) cumulative expired volume by 19.6 (5.0)%, functional residual capacity by 8.9 (2.2)%, and lung clearance index by 11.9 (4.0)%. It also substantially reduced the level of the tissue nitrogen signal at the end of measurements. CONCLUSIONS Inadequate correction for cross sensitivity in the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of functional residual capacity and lung clearance index. Correction of this error is possible and could be applied by re-analyzing the measurements in an updated software version

    Do clinimetric properties of LCI change after correction of signal processing?

    No full text
    BACKGROUND The recently described sensor-crosstalk error in the multiple-breath washout (MBW) device Exhalyzer D (Eco Medics AG, Duernten, Switzerland) could highly influence clinimetric properties and the current interpretation of MBW results. This study reanalyzes MBW data from clinical routine in the corrected software version Spiroware® 3.3.1 and evaluates the effect on outcomes. METHODS We included nitrogen-MBW data from healthy children and children with cystic fibrosis (CF) from previously published trials and ongoing cohort studies. We specifically compared lung clearance index (LCI) analyzed in Spiroware 3.2.1 and 3.3.1 with regards to i) feasibility, ii) repeatability and iii) validity as outcome parameters in children with CF. RESULTS (i) All previously collected measurements could be reanalyzed and resulted in unchanged feasibility in Spiroware 3.3.1. (ii) Short- and midterm repeatability of LCI was similar in both software versions. (iii) Clinical validity of LCI remained similar in Spiroware 3.3.1, however, resulted in lower values. Discrimination between health and disease was comparable between both software versions. The increase in LCI over time was less pronounced with 0.16 LCI units/year (95% CI 0.08; 0.24) vs. 0.30 LCI units/year (95% CI 0.21; 0.38) in 3.2.1. Response to intervention in children receiving CFTR-modulator therapy resulted in a comparable improvement in LCI in both Spiroware versions. CONCLUSION Our study confirms that clinimetric properties of LCI remain unaffected after correction for the cross-sensitivity error in Spiroware software. This article is protected by copyright. All rights reserved