6 research outputs found

    Occurrences of Cadmium, Arsenic, Lead, and Mercury in Potable Water in Greater Gaborone, Botswana: Implications for Public Health

    Get PDF
    Heavy metals, such as cadmium (Cd), arsenic (As), lead (Pb), and mercury (Hg), are often detected in water, causing detrimental effects to human health. This study assessed Cd, As, Pb, and Hg concentrations in drinking water from the greater Gaborone water distribution system supply area. The Inductively Coupled Plasma—Mass spectrometry was used to analyze 200 water samples from water treatment reservoirs, the distribution line, households, and bottled water. Heavy metal pollution was calculated using the heavy metal pollution index (HPI). Average heavy metal concentrations were in the order of Pb > Hg > As > Cd in the overall study, with lead exceeding the permissible limit set by the United States Environmental Protection Agency (US-EPA) in all the samples. Average lead concentrations from indoor taps were 15 times more than untreated raw water. HPI values were respectively 33.2 and 0.74 for the World Health Organization (WHO) and Botswana Bureau of Standards (BOBS). An increase in heavy metal concentrations post-water treatment suggests inadequate system maintenance and possible contamination of water during the distribution system from copper and lead soldered pipes. Further research on the treatment infrastructure and plumbing activities is suggested

    Anaerobic Digestion for Biogas Production from Municipal Sewage Sludge: A Comparative Study between Fine Mesh Sieved Primary Sludge and Sedimented Primary Sludge

    No full text
    Two different types of primary sewage sludge have been used as feedstock for production of biogas through anaerobic digestion (AD): the one type was sludge from a typical primary clarifier (PC), while the other type of sludge produced by a rotating belt filter, commonly called microsieve (MS). Initially the main physicochemical characteristics of the sludges, such as total solids (TS), volatile solids (VS), VS/TS, pH and carbon to nitrogen ratio (C/N) were determined, for MS: 37.86 ± 0.08%, 83.00 ± 0.41%, 0.83 ± 0.00, 6.67 ± 0.08 and 19.68 ± 0.69, respectively, and for PC: 2.61 ± 0.08%, 78.77 ± 1.91%, 0.79 ± 0.02, 6.61 ± 0.10 and 14.46 ± 1.23, respectively. Then, calculated amounts of the sludges were inserted into airtight vials and were inoculated using anaerobic sludge. The daily biogas production was measured over a period of 30 days. PC sludge maximized the daily biogas production (44.20 mlbiogas/gvsd) 11 days after inoculation, while the MS sludge reach a peak (37.74 mlbiogas/gvsd) 14 days after inoculation. The cumulative biogas production over the 30 days of AD was in the same laver (442.29 mlbiogas/gvs for PC versus 434.73 mlbiogas/gvs for MS). However, PC sludge indicated higher daily biogas production, compared to MS sludge, while the opposite was observed for the period following the peak point. The Volatile Solids Reduction for PC and MS sludges was recorded as 46.06% and 32.39%, respectively

    Assessment of probable causes of chlorine decay in water distribution systems of Gaborone city, Botswana

    Get PDF
    Assessment of probable causes of chlorine decay in water distribution systems of Gaborone city, Botswana Gaborone city water distribution system (GCWDS) is rapidly expanding and has been faced with the major problems of high water losses due to leakage, water shortages due to drought and inadequate chlorine residuals at remote areas of the network. This study investigated the probable causes of chlorine decay, due to pipe wall conditions and distribution system water quality in the GCWDS. An experimental approach, which applied a pipe-loop network model to estimate biofilm growth and chlorine reaction rate constants, was used to analyse pipe wall chlorine decay. Also, effects of key water quality parameters on chlorine decay were analysed. The water quality parameters considered were: natural organic matter (measured by total organic carbon, TOC; dissolved organic carbon, DOC; and ultraviolet absorbance at wavelength 254, UVA-254, as surrogates), inorganic compounds (iron and manganese) and heterotrophic plate count (HPC). Samples were collected from selected locations in the GCWDS for analysis of water quality parameters. The results of biofilm growth and chlorine reaction rate constants revealed that chlorine decay was higher in pipe walls than in the bulk of water in the GCWDS. The analysis of key water quality parameters revealed the presence of TOC, DOC and significant levels of organics (measured by UVA-254), which suggests that organic compounds contributed to chlorine decay in the GCWDS. However, low amounts of iron and manganese (< 0.3 mg/L) indicated that inorganic compounds may have had insignificant contributions to chlorine decay. The knowledge gained on chlorine decay would be useful for improving water treatment and network operating conditions so that appropriate chlorine residuals are maintained to protect the network from the risks of poor water quality that may occur due to the aforementioned problems

    Anaerobic Digestion for Biogas Production from Municipal Sewage Sludge: A Comparative Study between Fine Mesh Sieved Primary Sludge and Sedimented Primary Sludge

    No full text
    Two different types of primary sewage sludge have been used as feedstock for production of biogas through anaerobic digestion (AD): the one type was sludge from a typical primary clarifier (PC), while the other type of sludge produced by a rotating belt filter, commonly called microsieve (MS). Initially the main physicochemical characteristics of the sludges, such as total solids (TS), volatile solids (VS), VS/TS, pH and carbon to nitrogen ratio (C/N) were determined, for MS: 37.86 ± 0.08%, 83.00 ± 0.41%, 0.83 ± 0.00, 6.67 ± 0.08 and 19.68 ± 0.69, respectively, and for PC: 2.61 ± 0.08%, 78.77 ± 1.91%, 0.79 ± 0.02, 6.61 ± 0.10 and 14.46 ± 1.23, respectively. Then, calculated amounts of the sludges were inserted into airtight vials and were inoculated using anaerobic sludge. The daily biogas production was measured over a period of 30 days. PC sludge maximized the daily biogas production (44.20 mlbiogas/gvsd) 11 days after inoculation, while the MS sludge reach a peak (37.74 mlbiogas/gvsd) 14 days after inoculation. The cumulative biogas production over the 30 days of AD was in the same laver (442.29 mlbiogas/gvs for PC versus 434.73 mlbiogas/gvs for MS). However, PC sludge indicated higher daily biogas production, compared to MS sludge, while the opposite was observed for the period following the peak point. The Volatile Solids Reduction for PC and MS sludges was recorded as 46.06% and 32.39%, respectively

    Anaerobic digestion for biogas production from municipal sewage sludge: a comparative study between fine mesh sieved primary sludge and sedimented primary sludge

    No full text
    Summarization: Two different types of primary sewage sludge have been used as feedstock for production of biogas through anaerobic digestion (AD): the one type was sludge from a typical primary clarifier (PC), while the other type of sludge produced by a rotating belt filter, commonly called microsieve (MS). Initially the main physicochemical characteristics of the sludges, such as total solids (TS), volatile solids (VS), VS/TS, pH and carbon to nitrogen ratio (C/N) were determined, for MS: 37.86 ± 0.08%, 83.00 ± 0.41%, 0.83 ± 0.00, 6.67 ± 0.08 and 19.68 ± 0.69, respectively, and for PC: 2.61 ± 0.08%, 78.77 ± 1.91%, 0.79 ± 0.02, 6.61 ± 0.10 and 14.46 ± 1.23, respectively. Then, calculated amounts of the sludges were inserted into airtight vials and were inoculated using anaerobic sludge. The daily biogas production was measured over a period of 30 days. PC sludge maximized the daily biogas production (44.20 mlbiogas/gvsd) 11 days after inoculation, while the MS sludge reach a peak (37.74 mlbiogas/gvsd) 14 days after inoculation. The cumulative biogas production over the 30 days of AD was in the same laver (442.29 mlbiogas/gvs for PC versus 434.73 mlbiogas/gvs for MS). However, PC sludge indicated higher daily biogas production, compared to MS sludge, while the opposite was observed for the period following the peak point. The Volatile Solids Reduction for PC and MS sludges was recorded as 46.06% and 32.39%, respectively.Παρουσιάστηκε στο: Wate
    corecore