Performance Of A Liquid Argon Time Projection Chamber Exposed To The WANF Neutrino Beam
We present the results of the first exposure of a Liquid Argon TPC to a
multi-GeV neutrino beam. The data have been collected with a 50 liters
ICARUS-like chamber located between the CHORUS and NOMAD experiments at the
CERN West Area Neutrino Facility (WANF). We discuss both the instrumental
performance of the detector and its capability to identify and reconstruct low
multiplicity neutrino interactions.Comment: 14 pages, 12 figures. Submitted for publication to Physical Review
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
We describe a search method for fast moving ()
magnetic monopoles using simultaneously the scintillator, streamer tube and
track-etch subdetectors of the MACRO apparatus. The first two subdetectors are
used primarily for the identification of candidates while the track-etch one is
used as the final tool for their rejection or confirmation. Using this
technique, a first sample of more than two years of data has been analyzed
without any evidence of a magnetic monopole. We set a 90% CL upper limit to the
local monopole flux of in the
velocity range and for nucleon decay
catalysis cross section smaller than .Comment: 29 pages (12 figures). Accepted by Astroparticle Physic
Social interaction, noise and antibiotic-mediated switches in the intestinal microbiota
The intestinal microbiota plays important roles in digestion and resistance
against entero-pathogens. As with other ecosystems, its species composition is
resilient against small disturbances but strong perturbations such as
antibiotics can affect the consortium dramatically. Antibiotic cessation does
not necessarily restore pre-treatment conditions and disturbed microbiota are
often susceptible to pathogen invasion. Here we propose a mathematical model to
explain how antibiotic-mediated switches in the microbiota composition can
result from simple social interactions between antibiotic-tolerant and
antibiotic-sensitive bacterial groups. We build a two-species (e.g. two
functional-groups) model and identify regions of domination by
antibiotic-sensitive or antibiotic-tolerant bacteria, as well as a region of
multistability where domination by either group is possible. Using a new
framework that we derived from statistical physics, we calculate the duration
of each microbiota composition state. This is shown to depend on the balance
between random fluctuations in the bacterial densities and the strength of
microbial interactions. The singular value decomposition of recent metagenomic
data confirms our assumption of grouping microbes as antibiotic-tolerant or
antibiotic-sensitive in response to a single antibiotic. Our methodology can be
extended to multiple bacterial groups and thus it provides an ecological
formalism to help interpret the present surge in microbiome data.Comment: 20 pages, 5 figures accepted for publication in Plos Comp Bio.
Supplementary video and information availabl
The Observation of Up-going Charged Particles Produced by High Energy Muons in Underground Detectors
An experimental study of the production of up-going charged particles in
inelastic interactions of down-going underground muons is reported, using data
obtained from the MACRO detector at the Gran Sasso Laboratory. In a sample of
12.2 10^6 single muons, corresponding to a detector livetime of 1.55 y, 243
events are observed having an up-going particle associated with a down-going
muon. These events are analysed to determine the range and emission angle
distributions of the up-going particle, corrected for detection and
reconstruction efficiency. Measurements of the muon neutrino flux by
underground detectors are often based on the observation of through-going and
stopping muons produced in interactions in the rock below the
detector. Up-going particles produced by an undetected down-going muon are a
potential background source in these measurements. The implications of this
background for neutrino studies using MACRO are discussed.Comment: 18 pages, 9 figures. Accepted by Astrop. Physic
Final results of magnetic monopole searches with the MACRO experiment
We present the final results obtained by the MACRO experiment in the search
for GUT magnetic monopoles in the penetrating cosmic radiation, for the range
. Several searches with all the MACRO sub-detectors
(i.e. scintillation counters, limited streamer tubes and nuclear track
detectors) were performed, both in stand alone and combined ways. No candidates
were detected and a 90% Confidence Level (C.L.) upper limit to the local
magnetic monopole flux was set at the level of cm
s sr. This result is the first experimental limit obtained in
direct searches which is well below the Parker bound in the whole range
in which GUT magnetic monopoles are expected.Comment: 12 pages, Latex, 9 figures and 2 Table
Muon Energy Estimate Through Multiple Scattering with the Macro Detector
Muon energy measurement represents an important issue for any experiment
addressing neutrino induced upgoing muon studies. Since the neutrino
oscillation probability depends on the neutrino energy, a measurement of the
muon energy adds an important piece of information concerning the neutrino
system. We show in this paper how the MACRO limited streamer tube system can be
operated in drift mode by using the TDC's included in the QTPs, an electronics
designed for magnetic monopole search. An improvement of the space resolution
is obtained, through an analysis of the multiple scattering of muon tracks as
they pass through our detector. This information can be used further to obtain
an estimate of the energy of muons crossing the detector. Here we present the
results of two dedicated tests, performed at CERN PS-T9 and SPS-X7 beam lines,
to provide a full check of the electronics and to exploit the feasibility of
such a multiple scattering analysis. We show that by using a neural network
approach, we are able to reconstruct the muon energy for 40 GeV. The
test beam data provide an absolute energy calibration, which allows us to apply
this method to MACRO data.Comment: 25 pages, 11 figures, Submitted to Nucl. Instr. & Meth.
Nuclearite search with the MACRO detector at Gran Sasso
In this paper we present the results of a search for nuclearites in the
penetrating cosmic radiation using the scintillator and track-etch subdetectors
of the MACRO apparatus. The analyses cover the beta =v/c range at the detector
depth (3700 hg/cm^2) 10^-5 < beta < 1; for beta = 2 x 10^-3 the flux limit is
2.7 x 10^-16 cm^-2 s^-1 sr^-1 for an isotropic flux of nuclearites, and twice
this value for a flux of downgoing nuclearites.Comment: 16 pages, 4 Encapsulated Postscript figures, uses article.sty.
Submitted to The European Physical Journal
Atmospheric neutrino induced muons in the MACRO detector
A measurement of the flux of neutrino-induced muons using the MACRO detector
is presented. Different event topologies, corresponding to different neutrino
parent energies can be detected. The upward throughgoing muon sample is the
larger event sample. The observed upward-throughgoing muons are 26% fewer than
expected and the zenith angle distribution does not fit with the expected one.
Assuming neutrino oscillations, both measurements suggest maximum mixing and
Dm2 of a few times 10-3 eV2. The other samples are due to the internally
produced events and to upward-going stopping muons. These data show a regular
deficit of observed events in each angular bin, as expected assuming neutrino
oscillations with maximum mixing, in agreement with the analysis of the
upward-throughgoing muon sample.Comment: 7 pages 6 figures to appear in the proceedings of XVIII International
Conference on Neutrino Physics and Astrophysics (Neutrino'98), Takayama,
Japan 4-9 June, 199
Measurement of the residual energy of muons in the Gran Sasso underground Laboratories
The MACRO detector was located in the Hall B of the Gran Sasso underground
Laboratories under an average rock overburden of 3700 hg/cm^2. A transition
radiation detector composed of three identical modules, covering a total
horizontal area of 36 m^2, was installed inside the empty upper part of the
detector in order to measure the residual energy of muons. This paper presents
the measurement of the residual energy of single and double muons crossing the
apparatus. Our data show that double muons are more energetic than single ones.
This measurement is performed over a standard rock depth range from 3000 to
6500 hg/cm^2.Comment: 28 pages, 9 figure
Search for Nucleon Decays induced by GUT Magnetic Monopoles with the MACRO Experiment
The interaction of a Grand Unification Magnetic Monopole with a nucleon can
lead to a barion-number violating process in which the nucleon decays into a
lepton and one or more mesons (catalysis of nucleon decay). In this paper we
report an experimental study of the effects of a catalysis process in the MACRO
detector. Using a dedicated analysis we obtain new magnetic monopole (MM) flux
upper limits at the level of for
, based on the search for
catalysis events in the MACRO data. We also analyze the dependence of the MM
flux limit on the catalysis cross section.Comment: 12 pages, Latex, 10 figures and 2 Table
- …