595 research outputs found

    About the Algebraic Solutions of Smallest Enclosing Cylinders Problems

    Full text link
    Given n points in Euclidean space E^d, we propose an algebraic algorithm to compute the best fitting (d-1)-cylinder. This algorithm computes the unknown direction of the axis of the cylinder. The location of the axis and the radius of the cylinder are deduced analytically from this direction. Special attention is paid to the case d=3 when n=4 and n=5. For the former, the minimal radius enclosing cylinder is computed algebrically from constrained minimization of a quartic form of the unknown direction of the axis. For the latter, an analytical condition of existence of the circumscribed cylinder is given, and the algorithm reduces to find the zeroes of an one unknown polynomial of degree at most 6. In both cases, the other parameters of the cylinder are deduced analytically. The minimal radius enclosing cylinder is computed analytically for the regular tetrahedron and for a trigonal bipyramids family with a symmetry axis of order 3.Comment: 13 pages, 0 figure; revised version submitted to publication (previous version is a copy of the original one of 2010

    Dosage du carbone organique dissous dans les eaux douces naturelles. Intérêt, Principe, Mise en Oeuvre et Précautions Opératoires

    No full text
    International audienceCe mémoire présente un travail de validation du dosage du carbone organique dissous(COD) et du carbone inorganique (CI) contenus dans les eaux douces naturelles développé surl'analyseur Shimadzu©, modèle TOC 5050A.Les limites de détection calculées pour cet analyseur avec un catalyseur de sensibilitédite normale sont de 0.31 ppm pour le COD et de 0.10 ppm pour le CI, respectivement. Leslimites de quantification sont logiquement plus élevées: 0.41 ppm (COD) et 0.13 ppm (CI).Ces résultats permettent de conclure que le catalyseur dit de "sensibilité normale" qui équipeen routine cet analyseur est adapté à l'analyse de la plupart des eaux douces naturelles.Les tests d'étalonnage effectués ont montré que l'appareil Shimadzu© TOC 5050A étaittrès stable dans le temps, les dérives constatées étant inférieures à 5%. De ce fait, uneprocédure allégée d'étalonnage comprenant l'injection d'un seul point de gamme en début dechaque série d'échantillons suffit à garantir une bonne justesse des résultats, même si celle-ciest difficile à quantifier du fait de l'absence de solutions standard certifiées.Les trois méthodes susceptibles d'être mises en oeuvre par l'analyseur Shimadzu©, TOC5050A (COD = CT – CI; NPOC, NPIW) ont été testées. Seules la méthode COD = CT – CIpermet de doser la totalité du compartiment "matière organique dissoute" des eaux doucesnaturelles. Les deux autres ne permettent pas d'appréhender les molécules les plus volatiles,les écarts entre valeurs "vraies" et valeurs "mesurées" pouvant aller jusqu'à 25%.Des expériences visant à tester les modalités de préparation et de conservation deséchantillons ont également été effectuées. Les résultats montrent que pour des eaux peuchargées en matière organique (COD 5%) entre valeurs mesurées et valeurs vraies. Dans ce cas,l'opérateur soucieux de produire des résultats justes sera conduit à filtrer les eaux directementsur le terrain et à réduire au maximum l'intervalle de temps entre le prélèvement et l'analyse

    Adversarial Convolutional Networks with Weak Domain-Transfer for Multi-sequence Cardiac MR Images Segmentation

    Get PDF
    Analysis and modeling of the ventricles and myocardium are important in the diagnostic and treatment of heart diseases. Manual delineation of those tissues in cardiac MR (CMR) scans is laborious and time-consuming. The ambiguity of the boundaries makes the segmentation task rather challenging. Furthermore, the annotations on some modalities such as Late Gadolinium Enhancement (LGE) MRI, are often not available. We propose an end-to-end segmentation framework based on convolutional neural network (CNN) and adversarial learning. A dilated residual U-shape network is used as a segmentor to generate the prediction mask; meanwhile, a CNN is utilized as a discriminator model to judge the segmentation quality. To leverage the available annotations across modalities per patient, a new loss function named weak domain-transfer loss is introduced to the pipeline. The proposed model is evaluated on the public dataset released by the challenge organizer in MICCAI 2019, which consists of 45 sets of multi-sequence CMR images. We demonstrate that the proposed adversarial pipeline outperforms baseline deep-learning methods.Comment: 9 pages, 4 figures, conferenc

    Multi-Estimator Full Left Ventricle Quantification through Ensemble Learning

    Full text link
    Cardiovascular disease accounts for 1 in every 4 deaths in United States. Accurate estimation of structural and functional cardiac parameters is crucial for both diagnosis and disease management. In this work, we develop an ensemble learning framework for more accurate and robust left ventricle (LV) quantification. The framework combines two 1st-level modules: direct estimation module and a segmentation module. The direct estimation module utilizes Convolutional Neural Network (CNN) to achieve end-to-end quantification. The CNN is trained by taking 2D cardiac images as input and cardiac parameters as output. The segmentation module utilizes a U-Net architecture for obtaining pixel-wise prediction of the epicardium and endocardium of LV from the background. The binary U-Net output is then analyzed by a separate CNN for estimating the cardiac parameters. We then employ linear regression between the 1st-level predictor and ground truth to learn a 2nd-level predictor that ensembles the results from 1st-level modules for the final estimation. Preliminary results by testing the proposed framework on the LVQuan18 dataset show superior performance of the ensemble learning model over the two base modules.Comment: Jiasha Liu, Xiang Li and Hui Ren contribute equally to this wor

    FastVentricle: Cardiac Segmentation with ENet

    Full text link
    Cardiac Magnetic Resonance (CMR) imaging is commonly used to assess cardiac structure and function. One disadvantage of CMR is that post-processing of exams is tedious. Without automation, precise assessment of cardiac function via CMR typically requires an annotator to spend tens of minutes per case manually contouring ventricular structures. Automatic contouring can lower the required time per patient by generating contour suggestions that can be lightly modified by the annotator. Fully convolutional networks (FCNs), a variant of convolutional neural networks, have been used to rapidly advance the state-of-the-art in automated segmentation, which makes FCNs a natural choice for ventricular segmentation. However, FCNs are limited by their computational cost, which increases the monetary cost and degrades the user experience of production systems. To combat this shortcoming, we have developed the FastVentricle architecture, an FCN architecture for ventricular segmentation based on the recently developed ENet architecture. FastVentricle is 4x faster and runs with 6x less memory than the previous state-of-the-art ventricular segmentation architecture while still maintaining excellent clinical accuracy.Comment: 11 pages, 6 figures, Accepted to Functional Imaging and Modeling of the Heart (FIMH) 201

    Automatic alignment of surgical videos using kinematic data

    Full text link
    Over the past one hundred years, the classic teaching methodology of "see one, do one, teach one" has governed the surgical education systems worldwide. With the advent of Operation Room 2.0, recording video, kinematic and many other types of data during the surgery became an easy task, thus allowing artificial intelligence systems to be deployed and used in surgical and medical practice. Recently, surgical videos has been shown to provide a structure for peer coaching enabling novice trainees to learn from experienced surgeons by replaying those videos. However, the high inter-operator variability in surgical gesture duration and execution renders learning from comparing novice to expert surgical videos a very difficult task. In this paper, we propose a novel technique to align multiple videos based on the alignment of their corresponding kinematic multivariate time series data. By leveraging the Dynamic Time Warping measure, our algorithm synchronizes a set of videos in order to show the same gesture being performed at different speed. We believe that the proposed approach is a valuable addition to the existing learning tools for surgery.Comment: Accepted at AIME 201

    A high-pressure hydrogen time projection chamber for the MuCap experiment

    Full text link
    The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, μ+pn+νμ\mu^- + p \rightarrow n + \nu_\mu. The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stopping target. The TPC detected the tracks of individual muon arrivals in three dimensions, while the trajectories of outgoing decay (Michel) electrons were measured by two surrounding wire chambers and a plastic scintillation hodoscope. The muon and electron detectors together enabled a precise measurement of the μp\mu p atom's lifetime, from which the nuclear muon capture rate was deduced. The TPC was also used to monitor the purity of the hydrogen gas by detecting the nuclear recoils that follow muon capture by elemental impurities. This paper describes the TPC design and performance in detail.Comment: 15 pages, 13 figures, to be submitted to Eur. Phys. J. A; clarified section 3.1.2 and made minor stylistic corrections for Eur. Phys. J. A requirement

    Inclusive Electron-Nucleus Scattering at Large Momentum Transfer

    Get PDF
    Inclusive electron scattering is measured with 4.045 GeV incident beam energy from C, Fe and Au targets. The measured energy transfers and angles correspond to a kinematic range for Bjorken x>1x > 1 and momentum transfers from Q2=17(GeV/c)2Q^2 = 1 - 7 (GeV/c)^2. When analyzed in terms of the y-scaling function the data show for the first time an approach to scaling for values of the initial nucleon momenta significantly greater than the nuclear matter Fermi-momentum (i.e. >0.3> 0.3 GeV/c).Comment: 5 pages TEX, 5 Postscript figures also available at http://www.krl.caltech.edu/preprints/OAP.htm

    Correlated Strength in Nuclear Spectral Function

    Full text link
    We have carried out an (e,e'p) experiment at high momentum transfer and in parallel kinematics to measure the strength of the nuclear spectral function S(k,E) at high nucleon momenta k and large removal energies E. This strength is related to the presence of short-range and tensor correlations, and was known hitherto only indirectly and with considerable uncertainty from the lack of strength in the independent-particle region. This experiment confirms by direct measurement the correlated strength predicted by theory.Comment: 4 pages, 2 figures, accepted by Phys. Rev. Let
    corecore