46 research outputs found

    An international recommendation framework of core competencies in health informatics for nurses.

    Get PDF
    Background: While health informatics recommendations on competencies and education serve as highly desirable corridors for designing curricula and courses, they cannot show how the content should be situated in a specific and local context. Therefore, global and local perspectives need to be reconciled in a common framework.Objectives: The primary aim of this study is therefore to empirically define and validate a framework of globally accepted core competency areas in health informatics and to enrich this framework with exemplar information derived from local educational settings.Methods: To this end, (i) a survey was deployed and yielded insights from 43 nursing experts from 21 countries worldwide to measure the relevance of the core competency areas, (ii) a workshop at the International Nursing Informatics Conference (NI2016) held in June 2016 to provide information about the validation and clustering of these areas and (iii) exemplar case studies were compiled to match these findings with the practice. The survey was designed based on a comprehensive compilation of competencies from the international literature in medical and health informatics.Results: The resulting recommendation framework consists of 24 core competency areas in health informatics defined for five major nursing roles. These areas were clustered in the domains “data, information, knowledge”, “information exchange and information sharing”, “ethical and legal issues”, “systems life cycle management”, “management” and “biostatistics and medical technology”, all of which showed high reliability values. The core competency areas were ranked by relevance and validated by a different group of experts. Exemplar case studies from Brazil, Germany, New Zealand, Taiwan/China, United Kingdom (Scotland) and the United States of America expanded on the competencies described in the core competency areas.Conclusions: This international recommendation framework for competencies in health informatics directed at nurses provides a grid of knowledge for teachers and learner alike that is instantiated with knowledge about informatics competencies, professional roles, priorities and practical, local experience. It also provides a methodology for developing frameworks for other professions/disciplines. Finally, this framework lays the foundation of cross-country learning in health informatics education for nurses and other health professionals

    Disposable Platform Provides Visual and Color-Based Point-of-Care Anemia Self-Testing

    Get PDF
    Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, standalone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels. METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying degrees and etiologies and compared hematology analyzer Hgb levels with POC Hgb levels, which were estimated via visual interpretation using a color scale and an optional smartphone app for automated analysis. RESULTS. POC Hgb levels correlated with hematology analyzer Hgb levels (r = 0.864 and r = 0.856 for visual interpretation and smartphone app, respectively), and both POC test methods yielded comparable sensitivity and specificity for detecting any anemia (n = 178) (/dl) (sensitivity: 90.2% and 91.1%, specificity: 83.7% and 79.2%, respectively) and severe anemia (n = 10) (/dl) (sensitivity: 90.0% and 100%, specificity: 94.6% and 93.9%, respectively). CONCLUSIONS. These results demonstrate the feasibility of this POC color-based diagnostic test for self-screening/self-monitoring of anemia. TRIAL REGISTRATION. Not applicable. FUNDING. This work was funded by the FDA-funded Atlantic Pediatric Device Consortium, the Georgia Research Alliance, Children\u27s Healthcare of Atlanta, the Georgia Center of Innovation for Manufacturing, and the InVenture Prize and Ideas to Serve competitions at the Georgia Institute of Technology

    Randomized controlled phase IIa clinical trial of safety, pharmacokinetics and pharmacodynamics of tenofovir and tenofovir plus levonorgestrel releasing intravaginal rings used by women in Kenya

    Get PDF
    IntroductionGlobally, many young women face the overlapping burden of HIV infection and unintended pregnancy. Protection against both may benefit from safe and effective multipurpose prevention technologies.MethodsHealthy women ages 18–34 years, not pregnant, seronegative for HIV and hepatitis B surface antigen, not using hormonal contraception, and at low risk for HIV were randomized 2:2:1 to continuous use of a tenofovir/levonorgestrel (TFV/LNG), TFV, or placebo intravaginal ring (IVR). In addition to assessing genital and systemic safety, we determined TFV concentrations in plasma and cervicovaginal fluid (CVF) and LNG levels in serum using tandem liquid chromatography-mass spectrometry. We further evaluated TFV pharmacodynamics (PD) through ex vivo CVF activity against both human immunodeficiency virus (HIV)-1 and herpes simplex virus (HSV)-2, and LNG PD using cervical mucus quality markers and serum progesterone for ovulation inhibition.ResultsAmong 312 women screened, 27 were randomized to use one of the following IVRs: TFV/LNG (n = 11); TFV-only (n = 11); or placebo (n = 5). Most screening failures were due to vaginal infections. The median days of IVR use was 68 [interquartile range (IQR), 36–90]. Adverse events (AEs) were distributed similarly among the three arms. There were two non-product related AEs graded >2. No visible genital lesions were observed. Steady state geometric mean amount (ssGMA) of vaginal TFV was comparable in the TFV/LNG and TFV IVR groups, 43,988 ng/swab (95% CI, 31,232, 61,954) and 30337 ng/swab (95% CI, 18,152, 50,702), respectively. Plasma TFV steady state geometric mean concentration (ssGMC) was <10 ng/ml for both TFV IVRs. In vitro, CVF anti-HIV-1 activity showed increased HIV inhibition over baseline following TFV-eluting IVR use, from a median of 7.1% to 84.4% in TFV/LNG, 15.0% to 89.5% in TFV-only, and −27.1% to −20.1% in placebo participants. Similarly, anti-HSV-2 activity in CVF increased >50 fold after use of TFV-containing IVRs. LNG serum ssGMC was 241 pg/ml (95% CI 185, 314) with rapid rise after TFV/LNG IVR insertion and decline 24-hours post-removal (586 pg/ml [95% CI 473, 726] and 87 pg/ml [95% CI 64, 119], respectively).ConclusionTFV/LNG and TFV-only IVRs were safe and well tolerated among Kenyan women. Pharmacokinetics and markers of protection against HIV-1, HSV-2, and unintended pregnancy suggest the potential for clinical efficacy of the multipurpose TFV/LNG IVR.Clinical Trial RegistrationNCT03762382 [https://clinicaltrials.gov/ct2/show/NCT03762382

    2023 SPARC Book Of Abstracts

    Get PDF

    The Role of Universal Stress Proteins in Bacterial Infections

    No full text

    Real-time pcr detection of dinophysis species in irish coastal waters

    No full text
    Diarrhetic shellfish toxin-producing Dinophysis species occur in Irish coastal waters throughout the year. Dinophysis acuta and Dinophysis acuminata are the most commonly occurring species and are responsible for the majority of closures of Irish mussel farms. This study describes the development of a qualitative real-time polymerase chain reaction (PCR) assay for identification of D. acuta and D. acuminata in Irish coastal waters. DNA sequence information for the D1-D2 region of the large ribosomal sub-unit (LSU) was obtained, following single-cell PCR of D. acuta and D. acuminata cells isolated from Irish coastal locations. PCR primers and hybridization probes, specific for the detection of D. acuta, were designed for real-time PCR on the LightCycler (TM). The LightCycler (TM) software melt curve analysis programme determined that D. acuta was identified by a melt-peak at 61A degrees C, while D. acuminata cells produced a melt peak at 48A degrees C. The limit of detection of the real-time PCR assay was determined to be one to ten plasmid copies of the LSU D1-D2 target region for both species and one to five D. acuminata cells. Lugol\u27s preserved water samples were also tested with the assay. The real-time PCR assay identified Dinophysis species in 100% of samples found to contain Dinophysis species by light microscopy and had a greater than 90% correlation with light microscopy for identification of D. acuta and D. acuminata in the samples. The assay can identify and discriminate D. acuta and D. acuminata at low numbers in Irish waters and has the potential to add value to the Irish phytoplankton monitoring programme

    Real-time pcr detection of dinophysis species in irish coastal waters

    No full text
    Diarrhetic shellfish toxin-producing Dinophysis species occur in Irish coastal waters throughout the year. Dinophysis acuta and Dinophysis acuminata are the most commonly occurring species and are responsible for the majority of closures of Irish mussel farms. This study describes the development of a qualitative real-time polymerase chain reaction (PCR) assay for identification of D. acuta and D. acuminata in Irish coastal waters. DNA sequence information for the D1-D2 region of the large ribosomal sub-unit (LSU) was obtained, following single-cell PCR of D. acuta and D. acuminata cells isolated from Irish coastal locations. PCR primers and hybridization probes, specific for the detection of D. acuta, were designed for real-time PCR on the LightCycler (TM). The LightCycler (TM) software melt curve analysis programme determined that D. acuta was identified by a melt-peak at 61A degrees C, while D. acuminata cells produced a melt peak at 48A degrees C. The limit of detection of the real-time PCR assay was determined to be one to ten plasmid copies of the LSU D1-D2 target region for both species and one to five D. acuminata cells. Lugol's preserved water samples were also tested with the assay. The real-time PCR assay identified Dinophysis species in 100% of samples found to contain Dinophysis species by light microscopy and had a greater than 90% correlation with light microscopy for identification of D. acuta and D. acuminata in the samples. The assay can identify and discriminate D. acuta and D. acuminata at low numbers in Irish waters and has the potential to add value to the Irish phytoplankton monitoring programme

    Variation in health care providers’ perceptions: decision making based on patient vital signs

    Get PDF
    Clinical decision making plays an imperative role when delivering healthcare services. To assist healthcare practitioners in decision making activities, Early Warning Scorecards (EWS) have been developed to classify patients based on their vital sign readings. This paper aims to evaluate the variation among healthcare practitioners’ perceptions of vital signs critical ranges and priorities, and if there is a variation between decisions made based on paper-based Modified EWS (MEWS) and electronic MEWS. A survey is conducted to analyse these variations for six vital sign parameters. Further investigation is carried out on the variations in decisions made for six simulated patients using the paper-based MEWS and eMEWS. Thus, the variations of decisions made for a given patient among the survey participants are analysed in light of paper-based MEWS and eMEWS. Therefore, this paper contributes to both theory and practice by identifying variations in health care providers’ perceptions when deciding the actions/treatment of patients
    corecore