120 research outputs found

    Plantar loading during jumping while wearing a rigid carbon graphite footplate

    Get PDF
    Fifth metatarsal stress fractures are common in sports and often result in delayed and non-union. The purpose of this study was to examine the effect of a rigid carbon graphite footplate (CGF) on plantar loading during take-off and landing from a jump. Nineteen recreational male athletes with no history of lower extremity injury in the past 6 months and no foot or ankle surgery in the past 3 years participated in this study. Subjects completed 7 jumping tasks while wearing a standard running shoe and then the shoe plus the CGF while plantar loading data was recorded. A series of paired t-tests were used to examine differences between the two footwear conditions independently for both takeoff and landing (α=0.05). The contact area in the medial midfoot (p<.001) and forefoot (p=.010) statistically decreased when wearing the CGFP. The force-time integral was significantly greater when wearing the CGFP in the middle (p<.001) and lateral forefoot (p=.019). Maximum force was significantly greater beneath the middle (p<.001) and lateral forefoot (p<.001) when wearing the CGFP, while it was decreased beneath the medial midfoot (p<.001). During landing, the contact area beneath the medial (p=.017) and lateral midfoot (p=.004) were significantly decreased when wearing the CGFP. The force-time integral was significantly decrease beneath the medial midfoot (p<.001) when wearing the CGFP. The maximum force was significantly greater beneath the medial (p=.047) and middle forefoot (p=.001) when the subject was wearing the CGFP. The maximum force beneath the medial midfoot (p<.001) was significantly reduced when wearing the carbon graphite footplate. The results of the study indicate that the CGF is ineffective at reducing plantar loading during jumping and landing. © 2013 Elsevier B.V

    Plantar Loading During Cutting While Wearing a Rigid Carbon Fiber Insert.

    Get PDF
    Context : Stress fractures are one of the most common injuries in sports, accounting for approximately 10% of all overuse injuries. Treatment of fifth metatarsal stress fractures involves both surgical and nonsurgical interventions. Fifth metatarsal stress fractures are difficult to treat because of the risks of delayed union, nonunion, and recurrent injuries. Most of these injuries occur during agility tasks, such as those performed in soccer, basketball, and lacrosse. Objective : To examine the effect of a rigid carbon graphite footplate on plantar loading during 2 agility tasks. Design :  Crossover study. Setting : Laboratory. Patients or Other Participants : A total of 19 recreational male athletes with no history of lower extremity injury in the past 6 months and no previous metatarsal stress fractures were tested. Main Outcome Measure(s) :  Seven 45° side-cut and crossover-cut tasks were completed in a shoe with or without a full-length rigid carbon plate. Testing order between the shoe conditions and the 2 cutting tasks was randomized. Plantar-loading data were recorded using instrumented insoles. Peak pressure, maximum force, force-time integral, and contact area beneath the total foot, the medial and lateral midfoot, and the medial, middle, and lateral forefoot were analyzed. A series of paired t tests was used to examine differences between the footwear conditions (carbon graphite footplate, shod) for both cutting tasks independently (α = .05). Results : During the side-cut task, the footplate increased total foot and lateral midfoot peak pressures while decreasing contact area and lateral midfoot force-time integral. During the crossover-cut task, the footplate increased total foot and lateral midfoot peak pressure and lateral forefoot force-time integral while decreasing total and lateral forefoot contact area. Conclusions : Although a rigid carbon graphite footplate altered some aspects of the plantar- pressure profile during cutting in uninjured participants, it was ineffective in reducing plantar loading beneath the fifth metatarsal

    Outcomes After Total Ankle Replacement in Association With Ipsilateral Hindfoot Arthrodesis.

    Get PDF
    BACKGROUND: Ipsilateral hindfoot arthrodesis in combination with total ankle replacement (TAR) may diminish functional outcome and prosthesis survivorship compared to isolated TAR. We compared the outcome of isolated TAR to outcomes of TAR with ipsilateral hindfoot arthrodesis. METHODS: In a consecutive series of 404 primary TARs in 396 patients, 70 patients (17.3%) had a hindfoot fusion before, after, or at the time of TAR; the majority had either an isolated subtalar arthrodesis (n = 43, 62%) or triple arthrodesis (n = 15, 21%). The remaining 334 isolated TARs served as the control group. Mean patient follow-up was 3.2 years (range, 24-72 months). RESULTS: The SF-36 total, AOFAS Hindfoot-Ankle pain subscale, Foot and Ankle Disability Index, and Short Musculoskeletal Function Assessment scores were significantly improved from preoperative measures, with no significant differences between the hindfoot arthrodesis and control groups. The AOFAS Hindfoot-Ankle total, function, and alignment scores were significantly improved for both groups, albeit the control group demonstrated significantly higher scores in all 3 scales. Furthermore, the control group demonstrated a significantly greater improvement in VAS pain score compared to the hindfoot arthrodesis group. Walking speed, sit-to-stand time, and 4-square step test time were significantly improved for both groups at each postoperative time point; however, the hindfoot arthrodesis group completed these tests significantly slower than the control group. There was no significant difference in terms of talar component subsidence between the fusion (2.6 mm) and control groups (2.0 mm). The failure rate in the hindfoot fusion group (10.0%) was significantly higher than that in the control group (2.4%; p < 0.05). CONCLUSION: To our knowledge, this study represents the first series evaluating the clinical outcome of TARs performed with and without hindfoot fusion using implants available in the United States. At follow-up of 3.2 years, TAR performed with ipsilateral hindfoot arthrodesis resulted in significant improvements in pain and functional outcome; in contrast to prior studies, however, overall outcome was inferior to that of isolated TAR. LEVEL OF EVIDENCE: Level II, prospective comparative series

    Comparison of extramedullary versus intramedullary referencing for tibial component alignment in total ankle arthroplasty.

    Get PDF
    BACKGROUND: The majority of total ankle arthroplasty (TAA) systems use extramedullary alignment guides for tibial component placement. However, at least 1 system offers intramedullary referencing. In total knee arthroplasty, studies suggest that tibial component placement is more accurate with intramedullary referencing. The purpose of this study was to compare the accuracy of extramedullary referencing with intramedullary referencing for tibial component placement in total ankle arthroplasty. METHODS: The coronal and sagittal tibial component alignment was evaluated on the postoperative weight-bearing anteroposterior (AP) and lateral radiographs of 236 consecutive fixed-bearing TAAs. Radiographs were measured blindly by 2 investigators. The postoperative alignment of the prosthesis was compared with the surgeon's intended alignment in both planes. The accuracy of tibial component alignment was compared between the extramedullary and intramedullary referencing techniques using unpaired t tests. Interrater and intrarater reliabilities were assessed with intraclass correlation coefficients (ICCs). RESULTS: Eighty-three tibial components placed with an extramedullary referencing technique were compared with 153 implants placed with an intramedullary referencing technique. The accuracy of the extramedullary referencing was within a mean of 1.5 ± 1.4 degrees and 4.1 ± 2.9 degrees in the coronal and sagittal planes, respectively. The accuracy of intramedullary referencing was within a mean of 1.4 ± 1.1 degrees and 2.5 ± 1.8 degrees in the coronal and sagittal planes, respectively. There was a significant difference (P < .001) between the 2 techniques with respect to the sagittal plane alignment. Interrater ICCs for coronal and sagittal alignment were high (0.81 and 0.94, respectively). Intrarater ICCs for coronal and sagittal alignment were high for both investigators. CONCLUSIONS: Initial sagittal plane tibial component alignment was notably more accurate when intramedullary referencing was used. Further studies are needed to determine the effect of this difference on clinical outcomes and long-term survivability of the implants. LEVEL OF EVIDENCE: Level III, retrospective comparative study

    Resource utilization and costs before and after total joint arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to compare pre- and post-surgical healthcare costs in commercially insured total joint arthroplasty (TJA) patients with osteoarthritis (OA) in the United States (U.S.).</p> <p>Methods</p> <p>Using a large healthcare claims database, we identified patients over age 39 with hip or knee OA who underwent unilateral primary TJA (hip or knee) between 1/1/2006 and 9/30/2007. Utilization of healthcare services and costs were aggregated into three periods: 12 months "pre-surgery," 91 days "peri-operative," and 3 to 15 month "follow-up," Mean total pre-surgery costs were compared with follow-up costs using Wilcoxon signed-rank test.</p> <p>Results</p> <p>14,912 patients met inclusion criteria for the study. The mean total number of outpatient visits declined from pre-surgery to follow-up (18.0 visits vs 17.1), while the percentage of patients hospitalized increased (from 7.5% to 9.8%) (both <it>p </it>< 0.01). Mean total costs during the follow-up period were 18% higher than during pre-surgery (11,043vs.11,043 vs. 9,632, <it>p </it>< 0.01), largely due to an increase in the costs of inpatient care associated with hospital readmissions (3,300vs.3,300 vs. 1,817, p < 0.01). Pharmacotherapy costs were similar for both periods (2013[follow−up]vs.2013 [follow-up] vs. 1922 [pre-surgery], p = 0.33); outpatient care costs were slightly lower in the follow-up period (4338vs.4338 vs. 4571, <it>p </it>< 0.01). Mean total costs for the peri-operative period were $36,553.</p> <p>Conclusions</p> <p>Mean total utilization of outpatient healthcare services declined slightly in the first year following TJA (exclusive of the peri-operative period), while mean total healthcare costs increased during the same time period, largely due to increased costs associated with hospital readmissions. Further study is necessary to determine whether healthcare costs decrease in subsequent years.</p

    Sex differences in the morphological failure patterns following hip resurfacing arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Metal-on-metal hybrid hip resurfacing arthroplasty (with a cementless acetabular component and a cemented femoral component) is offered as an alternative to traditional total hip arthroplasty for the young and active adult with advanced osteoarthritis. Although it has been suggested that women are less appropriate candidates for metal-on-metal arthroplasty, the mechanisms of prosthesis failure has not been fully explained. While specific failure patterns, particularly osteonecrosis and delayed type hypersensitivity reactions have been suggested to be specifically linked to the sex of the patient, we wished to examine the potential influence of sex, clinical diagnosis, age of the patient and the size of the femoral component on morphological failure patterns in a large cohort of retrieved specimens following aseptic failure of hip resurfacing arthroplasty.</p> <p>Methods</p> <p>Femoral remnants retrieved from 173 hips with known patient's sex were morphologically analyzed for the cause of failure. The results were compared with the control group of the remaining 31 failures from patients of unknown sex. The odds ratios (OR) and 95% confidence intervals (CI) of the following morphologically defined variables were calculated using logistic regression analysis: periprosthetic fractures (n = 133), osteonecrosis (n = 151), the presence of excessive intraosseous lymphocyte infiltration (n = 11), and interface hyperosteoidosis (n = 30). Logistic regression analysis was performed both unadjusted and after adjustment for sex, age, the size of the femoral component, and preoperative clinical diagnosis.</p> <p>Results</p> <p>Femoral remnants from female patients had a smaller OR for fracture (adjusted OR: 0.29, 95% CI 0.11, 0.80, <it>P </it>for difference = 0.02) and for the presence of osteonecrosis (adjusted OR: 0.16, 95% CI 0.04, 0.63, <it>P </it>for difference = 0.01). However, women had a higher OR for both the presence of excessive intraosseous lymphocyte infiltration (adjusted OR: 10.22, 95% CI 0.79, 132.57, <it>P </it>for difference = 0.08) and interface hyperosteoidosis (adjusted OR: 4.19, 95% CI 1.14, 15.38, <it>P </it>for difference = 0.03).</p> <p>Conclusions</p> <p>Within the limitations of this study, we demonstrated substantial sex differences in distinct failure patterns of metal-on-metal hip resurfacing. Recognition of pathogenically distinct failure modes will enable further stratification of risk factors for certain failure mechanisms and thus affect future therapeutic options for selected patient groups.</p

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p

    Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty: Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    Get PDF
    Today, total hip arthroplasty (THA) is one of the safest and most efficient surgical treatments. New materials, surgical techniques and design concepts intended to improve THA have not always been successful. Thorough preclinical and early clinical investigations can detect some aspects of under-performing, while continuing surveillance is recommended to detect and analyze reasons for any later appearing flaws. In this thesis, several ways to monitor and assess THA performance are explored and carried out, using survival analysis in registry studies, radiostereometry (RSA), radiology and clinical outcome. In Paper I, a study using the Nordic Arthroplasty Register Association (NARA) registry shows that HRA had an almost 3-fold increased early non-septic revision risk and that risk factors were found to be female sex, certain HRA designs and units having performed few HRA procedures. Papers II and III contain comparisons of highly cross-linked polyethylene (XLPE) and conventional polyethylene (PE). XLPE had a considerably lower wear rate up to 10 years but showed no obvious improvements regarding implant fixation, BMD or clinical outcome. In the NARA registry, in 2 of 4 studied cup designs the XLPE version had a lower risk of revision for aseptic loosening compared to the PE version. Paper IV describes that stem subsidence and retrotorsion measured with RSA at 2 years predicted later aseptic stem failure in an unfavorably altered, previously well-functioning cemented femoral stem. In Paper V and VI, a novel approach to measure articulation wear with RSA in radiodense hip arthroplasty articulations was presented and evaluated. Subsequently, a comparison between ceramic-on-ceramic (COC) and metal-on-conventional PE uncemented THA displayed a considerably lower wear rate, smaller periacetabular bone lesions and a relatively high squeaking rate, the latter with unknown long-term consequences, in the COC hips. Implant fixation, heterotopic ossification and clinical outcome did not differ between articulation types. In conclusion, it was confirmed that implant surveillance can be done with RSA, also in radiodense THA. Early migration predicts later aseptic implant failure. Prolonged surveillance can confirm long-term material and design performance, verify or contradict anticipated advantages as well as detect unanticipated long-term complications
    • 

    corecore