79 research outputs found

    The effect of bacteriochlorophyll derivative WST-D and near infrared light on the molecular and fibrillar architecture of the corneal stroma

    Get PDF
    A cross-linking technique involving application of Bacteriochlorophyll Derivative WST-11 mixed with dextran (WST-D) to the epithelium-debrided cornea and illumination with Near Infrared (NIR), has been identified as a promising therapy for stiffening pathologically weakened corneas. To investigate its effect on corneal collagen architecture, x-ray scattering and electron microscopy data were collected from paired WST-D/NIR treated and untreated rabbit corneas. The treated eye received 2.5 mg/mL WST-D and was illuminated by a NIR diode laser (755 nm, 10 mW/cm2). An increase in corneal thickness (caused by corneal oedema) occurred at 1-day post-treatment but resolved in the majority of cases within 4 days. The epithelium was fully healed after 6–8 days. X-ray scattering revealed no difference in average collagen interfibrillar spacing, fibril diameter, D-periodicity or intermolecular spacing between treated and untreated specimens. Similarly, electron microscopy images of the anterior and posterior stroma in healed WST-D/NIR corneas and untreated controls revealed no obvious differences in collagen organisation or fibril diameter. As the size and organisation of stromal collagen is closely associated with the optical properties of the cornea, the absence of any large-scale changes following treatment confirms the potential of WST-D/NIR therapy as a means of safely stiffening the cornea

    Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation

    Get PDF
    Contains fulltext : 81835.pdf (Publisher’s version ) (Open Access)BACKGROUND: The repeatability and interchangeability of imaging devices measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are important in the assessment of patients considering refractive surgery. The purpose of this study was to investigate the agreement of CCT and ACD measurements using three imaging technologies in healthy eyes and in eyes after phakic intraocular lens implantation (pIOL). METHODS: In this comparative study, CCT and ACD were measured using anterior segment optical coherence tomography (AS-OCT), Orbscan II, and Pentacam in 33 healthy volunteers (66 eyes) and 22 patients (42 eyes) after pIOL implantation. Intraobserver repeatability was evaluated for all three devices in the healthy volunteer group. RESULTS: Pairwise comparison of CCT measurements showed significant differences between all devices (P < 0.001), except for the AS-OCT and Orbscan II in the healthy volunteer group (P = 0.422) and the Orbscan II and Pentacam in the pIOL group (P = 0.214). ACD measurements demonstrated significant differences between all pairwise comparisons in both groups (P < or = 0.001). Intraobserver reliability was high for CCT and ACD measurements in the healthy volunteer group, with coefficients of variation ranging from 0.6% to 1.2% and 0.4% to 0.5% respectively. CONCLUSIONS: CCT and ACD measurements using AS-OCT, Orbscan II, and Pentacam demonstrated high intraobserver reliability. However, these devices should not be used interchangeably for measurements of CCT and ACD in healthy subject and patients after pIOL implantation

    Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer

    Get PDF
    BACKGROUND: Recently, instruments for the measurement of wavefront aberration in the living human eye have been widely available for clinical applications. Despite the extensive background experience on wavefront sensing for research purposes, the information derived from such instrumentation in a clinical setting should not be considered a priori precise. We report on the variability of such an instrument at two different pupil sizes. METHODS: A clinical aberrometer (COAS Wavefront Scienses, Ltd) based on the Shack-Hartmann principle was employed in this study. Fifty consecutive measurements were perfomed on each right eye of four subjects. We compared the variance of individual Zernike expansion coefficients as determined by the aberrometer with the variance of coefficients calculated using a mathematical method for scaling the expansion coefficients to reconstruct wavefront aberration for a reduced-size pupil. RESULTS: Wavefront aberration exhibits a marked variance of the order of 0.45 microns near the edge of the pupil whereas the central part appears to be measured more consistently. Dispersion of Zernike expansion coefficients was lower when calculated by the scaling method for a pupil diameter of 3 mm as compared to the one introduced when only the central 3 mm of the Shack – Hartmann image was evaluated. Signal-to-noise ratio was lower for higher order aberrations than for low order coefficients corresponding to the sphero-cylindrical error. For each subject a number of Zernike expansion coefficients was below noise level and should not be considered trustworthy. CONCLUSION: Wavefront aberration data used in clinical care should not be extracted from a single measurement, which represents only a static snapshot of a dynamically changing aberration pattern. This observation must be taken into account in order to prevent ambiguous conclusions in clinical practice and especially in refractive surgery

    Assessing the accuracy of intracameral phenylephrine preparation in cataract surgery

    Get PDF
    Purpose: Unpreserved phenylephrine is often used as an off-licence intracameral surgical adjunct during cataract surgery to assist with pupil dilation and/or stabilise the iris in floppy iris syndrome. It can be delivered as a neat 0.2 ml bolus of either 2.5 or 10% strength, or in a range of ad-hoc dilutions. We wished to assess the accuracy of intracameral phenylephrine preparation in clinical practice. Methods: Phenylephrine 0.2 ml was analysed both neat (2.5 and 10%) and in diluted form (ratio of 1:1 and 1:3). Samples were analysed using the validated spectrophotometric method. Results: A total of 36 samples were analysed. The standard curve showed linearity for phenylephrine (R2 = 0.99). Wide variability was observed across all dilution groups. There was evidence of significant differences in the percentage deviations from intended results between dilutions (p &lt; 0.001). Mean percentage deviation for 1:3 dilution was significantly greater than neat (p = 0.003) and 1:1 dilution (p = 0.001). There was no evidence of a significant difference between 1:1 and neat (p = 0.827). Conclusions: Current ad-hoc dilution methods used to prepare intracameral phenylephrine are inaccurate and highly variable. Small volume 1 ml syringes should not be used for mixing or dilution of drug. Commercial intracameral phenylephrine products would address dosage concerns and could improve surgical outcomes in cases of poor pupil dilation and/or floppy iris syndrome
    • …
    corecore