428 research outputs found
Youth Use of E-Liquid Flavours – A systematic review exploring patterns of use of e liquid flavours and associations with continued vaping, tobacco smoking uptake, or cessation
Background and Aims:
There is concern that young people may be attracted to e-liquid flavours, prompting long-term vaping in naive users and potentially subsequent tobacco smoking. We aimed to review the use of e-liquid flavours by young people and describe associations with uptake or cessation of both regular vaping and tobacco smoking, adverse effects and subjective experiences.
Design:
Systematic review, including interventional, observational and qualitative studies reporting on the use of e-cigarette flavours by young people (aged < 18 years).
Setting:
Studies published in English language from any country or cultural setting.
Participants:
Young people and their carers (aged < 18 years).
Measurements:
A meta-analysis was not possible due to substantial heterogeneity, inconsistency in reporting of flavour categorizations and non-interventional study designs; thus, we narratively report findings.
Findings:
In total, 58 studies were included. The quality of the evidence was extremely low. Most (n = 39) studies were cross-sectional survey designs. In total, 11 longitudinal cohort studies assessed trajectories; eight qualitative studies reported on user experiences. Studies reported views and experiences of a total of 512 874 young people. Both cross-sectional and longitudinal studies suggested that flavours are important for initiation and continuation of vaping. Qualitative evidence shows interest and enjoyment in flavours. There was judged to be insufficient evidence that use of e-liquid flavours specifically is associated with uptake of smoking. No studies found clear associations between flavours and cessation in this population. We found no included reports of adverse effects of flavours.
Conclusions:
Flavours may be an important motivator for e-cigarette uptake, but the role of flavours in tobacco smoking uptake or cessation is unclear. The quality of the evidence on use of e-cigarette flavours by young people is low overall
Selective Deuterium Ion Acceleration Using the Vulcan PW Laser
We report on the successful demonstration of selective acceleration of
deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy
petawatt laser. TNSA typically produces a multi-species ion beam that
originates from the intrinsic hydrocarbon and water vapor contaminants on the
target surface. Using the method first developed by Morrison, et al., an
ion beam with 99 deuterium ions and peak energy 14 MeV/nucleon is
produced with a 200 J, 700 fs, laser pulse by cryogenically
freezing heavy water (DO) vapor onto the rear surface of the target prior
to the shot. Within the range of our detectors (0-8.5), we find
laser-to-deuterium-ion energy conversion efficiency of 4.3 above 0.7
MeV/nucleon while a conservative estimate of the total beam gives a conversion
efficiency of 9.4.Comment: 5 pages, 5 figure
A review of X-ray laser development at Rutherford Appleton Laboratory
Recent experiments undertaken at the Rutherford Appleton Laboratory to produce X-ray lasing over the 5-30 nm wavelength range are reviewed. The efficiency of lasing is optimized when the main pumping pulse interacts with a preformed plasma. Experiments using double 75-ps pulses and picosecond pulses superimposed on 300-ps background pulses are described. The use of travelling wave pumping with the approximately picosecond pulse experiments is necessary as the gain duration becomes comparable to the time for the X-ray laser pulse to propagate along the target length. Results from a model taking account of laser saturation and deviations from the speed of light c of the travelling wave and X-ray laser group velocity are presented. We show that X-ray laser pulses as short as 2-3 ps can be produced with optical pumping pulses of approximate to1-ps
Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers
A novel method for characterising the full spectrum of deuteron ions emitted
by laser driven multi-species ion sources is discussed. The procedure is based
on using differential filtering over the detector of a Thompson parabola ion
spectrometer, which enables discrimination of deuterium ions from heavier ion
species with the same charge-to-mass ratio (such as C6+, O8+, etc.). Commonly
used Fuji Image plates were used as detectors in the spectrometer, whose
absolute response to deuterium ions over a wide range of energies was
calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium
ion spectrum diagnosed in a recent experimental campaign is presented.Comment: 7 pages, 7 figure
Generation of intense quasi-electrostatic fields due to deposition of particles accelerated by petawatt-range laser-matter interactions
We demonstrate here for the first time that charge emitted by laser-target interactions at petawatt peak-powers can be efficiently deposited on a capacitor-collector structure far away from the target and lead to the rapid (tens of nanoseconds) generation of large quasi-static electric fields over wide (tens-of-centimeters scale-length) regions, with intensities much higher than common ElectroMagnetic Pulses (EMPs) generated by the same experiment in the same position. A good agreement was obtained between measurements from a classical field-probe and calculations based on particle-flux measurements from a Thomson spectrometer. Proof-of-principle particle-in-cell simulations reproduced the measurements of field evolution in time, giving a useful insight into the charging process, generation and distribution of fields. The understanding of this charging phenomenon and of the related intense fields, which can reach the MV/m order and in specific configurations might also exceed it, is very important for present and future facilities studying laser-plasma-acceleration and inertial-confinement-fusion, but also for application to the conditioning of accelerated charged-particles, the generation of intense electric and magnetic fields and many other multidisciplinary high-power laser-driven processes
Detector for imaging and dosimetry of laser-driven epithermal neutrons by alpha conversion
An epithermal neutron imager based on detecting alpha particles created by boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons below 0.1 eV, the fast neutrons register insignificantly in the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications
Laser-driven X-ray and neutron source development for industrial applications of plasma accelerators
Pulsed beams of energetic X-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and X-ray beam generation. Measurements and Monte-Carlo radiation transport simulations show that neutron yield is increased by a factor ~ 2 when a 1mm copper foil is placed behind a 2mm lithium foil, compared to using a 2cm block of lithium only. We explore X-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent Bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte-Carlo code. We also demonstrate the unique capability of laser-driven X-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10ps drive pulse is presented for the first time, demonstrating that features of 200µm size are resolved when projected at high magnification
- …